PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The test setup and measurement procedure of the shielding effectiveness of the industrial network Y distributors

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The paper presents the test set up and the measurement procedure of the relative value of the shielding effectiveness coefficient of the Y adapters. Such elements are widely used in IT networks in industrial automation systems. They are used for transmitting analogue and digital signals between the automation devices and different kinds of sensors, and for construction of industrial networks for data transfer. The paper presents the method of measuring the shielding effectiveness of such elements by measuring the signal attenuation between the radiating element and the internal wires of the tested element. The described test set up has been constructed in such way that minimize the signal penetration by the free space, that is outside the measuring zone. The test setup can be especially useful during the control of a process production and during preparation of new solutions. The construction and exemplary results of the tests were presented.
Rocznik
Tom
Strony
245--254
Opis fizyczny
Bibliogr. 9 poz, rys.
Twórcy
autor
  • Opole University of Technology 45-272 Opole, Sosnkowskiego 31
  • Opole University of Technology 45-272 Opole, Sosnkowskiego 31
Bibliografia
  • [1] David M. Pozar, Microwave Engineering, John Wiley & Sons, Inc, 2012.
  • [2] Golio M., Golio J., RF and Microwave Passive and Active Technologies, Taylor & Francis Group, 2008.
  • [3] Hoeft O. L., Transfer Impedance as a Measure of the Shielding Quality of Shielded Cables and Connectors, IEEE/EMC 2004 Symposium Workshop – Transfer Functions in EMC Shielding Design, 2004.
  • [4] Kleine-Ostmann T., Münter K., Schrader T., A new shielding effectiveness meas-urement method based on a skin-effect transmission line coupler, Advances in Radio Science, 5, pp. 37–42, 2007.
  • [5] Kopka R., Tarczyński W.: A system for research ICT connectors with cable, Opole University of Technology. Patent Application P.410237, 24.11.2014.
  • [6] Nowosielski L., Wnuk M., Przesmycki R., Piwowarczyk K., and Bugaj M, Coaxial Cables Shielding Efficiency Measuring Methodology, Progress In Electro-magnetics Research Symposium (PIERS 2012), KL, Malaysia, March 27–30, pp.72–76, 2012.
  • [7] Qi Zhang, Li-Hua Shi, Ying Hui Zhou, Cheng Gao, and Yong Chao Guo, Meas-urement of the Shielding Effectiveness of Connector by Improved Triaxial Meth-od, Progress In Electromagnetics Research Symposium (PIERS 2011), Suzhou, China, September 12-16, 2011, pp. 1334–1338, 2011.
  • [8] Więckowski W. T., Janukiewicz M. J., Methods for Evaluating the Shielding Ef-fectiveness of Textiles, FIBRES & TEXTILES in Eastern Europe, January / De-cember 2006, Vol. 14, No. 5 (59), pp. 18–22, 2006.
  • [9] EN 60512-23-3:2004 Electromechanical components for electronic equipment – Basic testing procedures and measuring methods – Part 23-3: Test 23c: Shielding effectiveness of connectors and accessories.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-841ce51f-08fb-43c5-b6c0-f71b3087e80a
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.