Evaluation of error in the performance of power corrected ophthalmic lenses

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In this work, we describe a new method for assessing the refractive correction error in power corrected ophthalmic lenses. The ideal power distribution map corresponding to the lens design to be measured is initially obtained. Then, using some known techniques, the real power distribution map of the lens under test is obtained. Finally, the difference between the two distributions is computed, obtaining a distribution map of the refractive correction error of the lens under analysis. In the paper, we describe the implementation of the proposed method using the Hartmann test to analyze a corrected power ophthalmic lens. The technique is analyzed, and its effects on measurement resolution discussed. This method can be useful to verify the designing errors in the lab or to verify manufacturing errors of ophthalmic lenses during mass production.
Czasopismo
Rocznik
Strony
s. 261--270
Opis fizyczny
Bibliogr. 18 poz., rys., wykr.
Twórcy
  • División de Estudios de Posgrado e Investigación, Instituto Tecnológico de Chihuahua, Ave. Tecnológico 2909, 31310 Chihuahua, México
  • División de Estudios de Posgrado e Investigación, Instituto Tecnológico de Chihuahua, Ave. Tecnológico 2909, 31310 Chihuahua, México
  • División de Estudios de Posgrado e Investigación, Instituto Tecnológico de Chihuahua, Ave. Tecnológico 2909, 31310 Chihuahua, México
  • División de Óptica, Centro de Investigaciones en Óptica, Lomas del Bosque 115, 37150 León, México
  • División de Estudios de Posgrado e Investigación, Instituto Tecnológico de Chihuahua, Ave. Tecnológico 2909, 31310 Chihuahua, México
Bibliografia
  • [1] MALACARA D., MALACARA Z., Handbook of Optical Design, 2nd Edition, Marcel Dekker, New York, 2003, pp. 315–332.
  • [2] BHOOTRA A.K., Ophthalmic Lenses, 1st Edition, Jaypee Brothers Medical Publishers, New Delhi, 2009, pp. 8–25.
  • [3] FOWLER C., LATHAM-PETRE K., Spectacle Lenses: Theory and Practice, 1st Edition, Butterworth--Heinemann, Oxford, 2001, pp. 79–97.
  • [4] JALIE M., Ophthalmic Lenses and Dispensing, 3th Edition, Butterworth-Heinemann, Oxford, 2008, pp. 29–41.
  • [5] SCHWIEGERLING J., Field Guide to Visual and Ophthalmic Optics, 3th Edition, SPIE Press, Bellingham, 2004, pp. 26–27.
  • [6] ATCHISON D.A., Spectacle lens design: a review, Applied Optics 31(19), 1992, pp. 3579–3585.
  • [7] MALACARA-DOBLADO D., Measuring the curvature of spherical wavefronts with Talbot interferometry, Optical Engineering 36(7), 1997, pp. 2016–2024.
  • [8] QUIROGA J. A., CRESPO D., BERNABEU E., Fourier transform method for automatic processing of moiré deflectograms, Optical Engineering 38(6), 1999, pp. 974–982.
  • [9] CANABAL H., ALONSO J., BERNABEU E., Laser beam deflectometry based on a subpixel resolution algorithm, Optical Engineering 40(11), 2001, pp. 2517–2523.
  • [10] CANABAL H., ALONSO J., Automatic wavefront measurement technique using a computer display and a charge-coupled device camera, Optical Engineering 41(4), 2002, pp. 822–826.
  • [11] GNANVO K., ZONG YAN WU, BOUGRENET DE LA TOCNAYE J.-L., LIREN LIU, Large-aperture automatic focimeter for the measurement of optical power and other optical characteristics of ophthalmic lenses, Applied Optics 41(28), 2002, pp. 5997–6005.
  • [12] POZO A. M., RUBIÑO M., Optical characterization of ophthalmic lenses by means of modulation transfer function determination from a laser speckle pattern, Applied Optics 44(36), 2005, pp. 7744–7748.
  • [13] TRUJILLO-SCHIAFFINO G., MALACARA-HERNÁNDEZ D., Refractive correction measurement in an ophthalmic lens, Review of Scientific Instruments 72(9), 2001, pp. 3622–3625.
  • [14] CHUANQING ZHOU, WEICHAO WANG, KUN YANG, XINYU CHAI, QIUSHI REN, Measurement and comparison of the optical performance of an ophthalmic lens based on a Hartmann–Shack wavefront sensor in real viewing conditions, Applied Optics 47(34), 2008, pp. 6434–6441.
  • [15] MALACARA-DOBLADO D., GOZEIL I., Hartamann, Hartmann–Shack and other screen tests, [In] Optical Shop Testing, Malacara D. [Ed.], 3th Edition, Wiley, New York, 2007, pp. 361–397.
  • [16] CANABAL H., QUIROGA J. A., BERNABEU E., Automatic processing in moiré deflectometry by local fringe direction calculation, Applied Optics 37(25), 1998, pp. 5894–5901.
  • [17] TRUJILLO-SCHIAFFINO G., MALACARA-HERNANDEZ D., Null test compensators for ophthalmic lenses, Optical Engineering 41(11), 2002, pp. 2910–2914.
  • [18] SALAS-PEIMBERT D.P., TRUJILLO-SCHIAFFINO G., GONZÁLEZ-SILVA J.A., ALMAZÁN-CUÉLLAR S., MALACARA-DOBLADO D., Simple Hartmann test data interpretation for ophthalmic lenses, Review of Scientific Instruments 77(4), 2006, article 043102.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-82204d11-6ad3-4736-a1a2-1686d9388e0b
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.