Reliability level versus load-carrying capacity of the uninterruptible power systems (UPS)

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The paper addresses the electric energy power supply, with particular emphasis on the functioning of the uninterruptible power supply systems (UPS). There were conducted considerations associated with the possibilities of covering the increasing demand for energy (as a result of the load infrastructure development) by parallel combining of the UPS power supplies. There were also analysed the possibilities of providing the expected reliability of the power supply of the priority loads as the effect of the redundancy introduction in the system. There are described the functional properties of the basic redundant UPS structures. The obtained results of studies performed in the UPS EVER POWERLINE GREEN 33 systems have been presented and commented on.
Rocznik
Tom
Strony
364--375
Opis fizyczny
Bibliogr. 12 poz., rys.
Twórcy
autor
  • EVER Sp. z o.o. 62-020 Swarzędz, ul. Grudzińskiego 30
Bibliografia
  • [1] Bednarek K., Jakość, pewność i właściwa konstrukcja układu zasilania a bezpieczeństwo urządzeń elektrycznych, Elektro.info, nr 12, 2012.
  • [2] Bednarek K., Poziom niezawodności a wzrost obciążalności systemów zasilania gwarantowanego (UPS), Poznan University of Technology Academic Journals, Electrical Engineering, No 78, Poznan 2014, p. 255-262.
  • [3] Bednarek K., Wzrost bezpieczeństwa energetycznego poprzez poprawę jakości i pewności zasilania elektrycznego, rozdział w książce: Bezpieczeństwo energetyczne. Rynki surowców i energii - teraźniejszość i przyszłość, tom 2. Technologia - Prawo - Ochrona środowiska, praca zbiorowa pod redakcją P. Kwiatkiewicza, Fundacja na rzecz Czystej Energii, Poznań 2014, s. 85-104.
  • [4] Bednarek K., Kasprzyk L., Functional analyses and application and discussion regarding energy storages in electric systems, in: Computer applications in electrical engineering, edited by R. Nawrowski, Publishing House of Poznan University of Technology, Poznań 2012, p. 228-243.
  • [5] Bednarek K., Kasprzyk L., Suppression of higher harmonic components introduction to the networks and improvement of the conditions of electric supply of electrical equipment, Przegląd Elektrotechniczny, No 12b, 2012, s. 236-239.
  • [6] Januszewski S., Świątek H., Zymmer K., Przyrządy energoelektroniczne i ich zastosowania. Zarys encyklopedyczny, Wydawnictwo Książkowe Instytutu Elektrotechniki, Warszawa 2008.
  • [7] Kuczyński K., Nadmiarowość w systemach zasilania rezerwowego, Elektro.info, nr 4, 2011.
  • [8] McCarthy K., Porównanie konfiguracji systemów zasilaczy UPS, WP75, American Power Conversion, 2004.
  • [9] Miegoń M., Układy zasilania gwarantowanego, Elektro.info, nr 6, 2009.
  • [10] Sosnowski J., Testowanie i niezawodność systemów komputerowych, Akademicka Oficyna Wydawnicza EXIT, Warszawa 2005.
  • [11] Wiatr J., Miegoń M., Zasilacze UPS oraz baterie akumulatorów w układach zasilania gwarantowanego, seria Zeszyty dla elektryków, nr 4, DW MEDIUM, Warszawa, 2008.