The influence of changing cooling water parameters on performance of steam condenser

Wybrane pełne teksty z tego czasopisma
Warianty tytułu
PL
Wpływ zmiany parametrów wody chłodzącej na pracę skraplacza parowego
Języki publikacji
EN
Abstrakty
EN
In this paper the influence of changing cooling water parameters on condenser operation has been presented. The analysis has been carried out for varying cooling water temperature and flow rate, for various thermal loads of the condenser, based on the test data as measured by independent measuring instruments. The test was carried out on an extraction-condensing turbine with rated power output over 100 MW. The influence of cooling parameters on condenser pressure, efficiency and parameter 5, as the condenser operation characteristic parameters, was tested. It has been shown that the lowest pressure in the condenser for a given steam load is obtained at the lowest temperature and the highest mass flow rate of cooling water. The cooling water temperature was being increased by changing the cooling tower operation setup, simulating the cooling conditions over the entire year. The cooling water flow rate was reduced by throttling the flap at the inlet to the condenser.
PL
W artykule przedstawiono wpływ zmiany parametrów wody chłodzącej na pracę skraplacza parowego. Analizę wykonano dla zmiennych temperatur oraz przepływu wody chłodzącej dla różnych obciążeń cieplnych skraplacza, opierając się na danych pomiarowych zmierzone niezależną aparatura pomiarową. Badania przeprowadzono na turbinie upustowo-kondensacyjnej o mocy nominalnej ponad 100 MW. Analizowano wpływ parametrów chłodzenia na ciśnienie w skraplaczu, sprawność oraz parametr 5, jako parametry charakterystyczne pracy wymiennika. Pokazano, że najniższe ciśnienie w skraplaczu dla danego obciążenia parowego uzyskuje się przy najniższej temperaturze oraz największym przepływie wody chłodzącej. Badania wykonywano w okresie zimowym. Temperaturę wody chłodzącej podwyższano przez zmianę konfiguracji pracy chłodni kominowej, symulując warunki chłodzenia w okresie całego roku. Przepływ wody chłodzącej zmniejszano przez dławienie klapą na wlocie do skraplacza.
Rocznik
Strony
17--29
Opis fizyczny
Bibliogr. 12 poz., rys.
Twórcy
autor
  • Poznan University of Technology, Faculty of Transport Engineering, Chair of Thermal Engineering
  • Poznan University of Technology, Faculty of Transport Engineering, Chair of Thermal Engineering
Bibliografia
  • [1] Boss DR 770 Baumann K., 1921. Some recent developments in large steam turbine practice. Journal of the Institution of Electrical Engineers, 59, 565-623.
  • [2] Błaszczyk A., Głuch J., Gardzilewicz A., 2011. Operating and economic conditions of cooling water control for marine steam turbine condensers. Polish Maritime Research, 18, 48-54.
  • [3] Eberle T., Schatz M., Starzmann J., Grubel M. Casey M., 2014. Experimental study of the effects of temperature variation on droplet size and wetness fraction in a low-pressure model steam turbine. Proceedings of the Institution of Mechanical Engineers, Part A: Journal of Power and Energy, 228, 97-106.
  • [4] Gardzilewicz A., Głuch J., Błaszczyk A., 2008. Economic and technical analysis of cooling water control in large-power steam turbines. Cieplne Maszyny Przepływowe - Turbomachinery, 133, 139-148.
  • [5] IAPWS-R7-97 2012. Revised release on the IAPWS industrial formulation 1997 for the Thermodynamic Properties of Water and Steam.
  • [6] Kostowski E., 2006. Heat Transfer (in Polish), WPŚ Gliwice.
  • [7] Laskowski R., Smyk A., Lewandowski J., Rusowicz A., 2015. Cooperation of a Steam Condenser with a Low-pressure Part of a Steam Turbine in Off-design Conditions. American Journal of Energy Research, 3, 13-18.
  • [8] Laudyn D., Pawlik M., Strzelczyk F., 2007. Power plants (in Polish), Warsaw, WNT.
  • [9] Mijakowski V., Mitrevski V., Mijakovski N., 2012. Possible efficiency improvement by application of various operating regimes for the cooling water pump station at thermal power plant bitola. Thermal Science, 16, 263-270.
  • [10] PN-EN60953-2 2000. Rules for steam turbine thermal acceptance test, part 2, Method B Wide range of accuracy for various types and sizes of turbines.
  • [11] Rusowicz A.W., 2013. Issues concerning mathematical modelling of power condensers (in Polish). Prace Naukowe Politechniki Warszawskiej, seria Mechanika. Warsaw University of Technologies.
  • [12] Łukowicz H., 2005. Analysis problems in flow calculations of steam turbines applied in diagnostics and design. Zeszyty Naukowe Politechniki Śląskiej, 143, 3-133.
Uwagi
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-813c7581-47f7-4812-bc49-64f53e029773
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.