Gas sensors based on conducting polymers – recent developments

Identyfikatory
Warianty tytułu
PL
Czujniki gazów wykorzystujące polimery przewodzące
Języki publikacji
EN
Abstrakty
EN
This work discusses sensing performance dependence of PEDOT polymer and its composites on the counter ions used in the polymerization process. The sensors based on PEDOT-RGO composite show reversible response to NO2, while on PEDOT/LiClO4 irreversible. As a result, PEDOT-RGO could be used as a typical gas sensor, while sensor based PEDOT/LiClO4 could be used as an integrating gas sensor, also known as an accumulating gas sensor. The irreversible nature of the response occurs also in the case of polypyrrole/LiClO4. The nature of PPy response to toxic gases does not allow using the sensor in a conventional way. However, the information about the concentration could be acquired from the response using a linear approximation, a non-linear approximation and a tangent method.
PL
Szybkie wykrywanie śladowych ilości toksycznych gazów w niedostatecznie wentylowanym środowisku jest niezbędne do skutecznej ochrony ludzkiego życia i mienia. Ochrona taka wymaga czujników zdolnych do wykrywania małych ilości gazu w krótkim czasie. Ostatnio wiele uwagi poświęca się nanotechnologii z użyciem polimerów przewodzących (CP) ze względu na ich właściwości fizyczne i chemiczne. Pomimo tych zalet, czujniki takie wciąż wymagają badań, które prowadzą do poprawy ich właściwości i umożliwią powszechne stosowanie. Użycie polimeru oraz tlenku grafenu/redukowanego tlenku grafenu, a także kompozytu polimer/RGO zmienia sposób działania czujnika i jego zastosowanie. Wielu naukowców wciąż sprzecza się co do roli polimerów oraz tlenku grafenu/redukowanego tlenku grafenu w czujnikach wykorzystujących kompozyt polimeru z GO/RGO. Wyjaśnienie tego stanowi wciąż duże wyzwanie. W artykule porównano różne zastosowania warstw polimerowych w zależności od użytego polimeru, a także w zależności od zastosowanej domieszki. Czujnik na bazie kompozytu PEDOT-RGO wykazuje odwracalną odpowiedź w obecności gazu NO2 i może zostać użyty jako tradycyjny czujnik gazu. Nieodwracalna natura odpowiedzi czujnika PEDOT-LiClO4 może być wykorzystana w zastosowaniu miernika całkowitego przepływu gazu NO2. Informacja o stężeniu gazu w przypadku czujnika PPy-LiClO4 może zostać wydobyta z użyciem aproksymacji liniowej, nieliniowej i metody tangensa.
Twórcy
autor
  • Gdańsk University of Technology, Faculty of Electronics, Telecommunications and Informatics, ul. Narutowicza 11/12, 80-233 Gdańsk, Poland
autor
  • Gdańsk University of Technology, Faculty of Electronics, Telecommunications and Informatics, ul. Narutowicza 11/12, 80-233 Gdańsk, Poland
Bibliografia
  • [1] L. Aba, Y. Yusuf, K. Triyana, Selectivity Improvement of Gas Sensor Based on Thin Film by Using Imprinting Method, 2012 (2012) 529–533.
  • [2] A.V. Murugan, A.K. Viswanath, C.S. Gopinath, K. Vijayamohanan, Highly efficient organic-inorganic poly(3,4-ethylenedioxythiophene)-molybdenum trioxide nanocomposite electrodes for electrochemical supercapacitor, J. Appl. Phys. 100 (2006) 74319. doi:10.1063/1.2356788.
  • [3] L. SETTI, A. FRALEONIMORGERA, I. MENCARELLI, A. FILIPPINI, B. BALLARIN, M. DIBIASE, An HRP-based amperometric biosensor fabricated by thermal inkjet printing, Sensors Actuators B Chem. 126 (2007) 252–257. doi:10.1016/j.snb.2006.12.015.
  • [4] P. Asberg, O. Inganäs, Hydrogels of a conducting conjugated polymer as 3-D enzyme electrode., Biosens. Bioelectron. 19 (2003) 199–207. http://www.ncbi.nlm.nih.gov/pubmed/14611755 (accessed July 12, 2017).
  • [5] C.-Y. Lin, J.-G. Chen, C.-W. Hu, J.J. Tunney, K.-C. Ho, Using a PEDOT:PSS modified electrode for detecting nitric oxide gas, Sensors Actuators B Chem. 140 (2009) 402–406. doi:10.1016/j.snb.2009.04.041.
  • [6] A. Balamurugan, S.-M. Chen, Poly(3,4-ethylenedioxythiophene-co-(5-amino-2-naphthalenesulfonic acid)) (PEDOT-PANS) film modified glassy carbon electrode for selective detection of dopamine in the presence of ascorbic acid and uric acid, Anal. Chim. Acta. 596 (2007) 92–98. doi:10.1016/j.aca.2007.05.064.
  • [7] A. BELLO, M. GIANNETTO, G. MORI, R. SEEBER, F. TERZI, C. ZANARDI, Optimization of the DPV potential waveform for determination of ascorbic acid on PEDOTmodified electrodes, Sensors Actuators B Chem. 121 (2007) 430–435. doi:10.1016/j.snb.2006.04.066.
  • [8] S.Y. Kim, G.T.R. Palmore, Electropolymerization vs. electrocrystallization: Electrosynthesis of poly(3,4-ethylenedioxythiophene) in the presence of 2,2?-azino-bis(3-ethylbenzothiaxoline-6-sulfonic acid), Electrochim. Acta. 77 (2012) 184–188. doi:10.1016/j.electacta.2012.05.107.
  • [9] K. Dunst, D. Jurków, P. Jasiński, Laser patterned platform with PEDOT–graphene composite film for NO2 sensing, Sensors Actuators B Chem. 229 (2016) 155–165. doi:10.1016/j.snb.2016.01.093.
  • [10] K.J. Dunst, K. Cysewska, P. Kalinowski, P. Jasiński, Polypyrrole based gas sensor for ammonia detection, IOP Conf. Ser. Mater. Sci. Eng. 104 (2016) 12028. doi:10.1088/1757-899X/104/1/012028.
  • [11] K.J. Dunst, B. Scheibe, G. Nowaczyk, S. Jurga, P. Jasiński, Graphene oxide, reduced graphene oxide and composite thin films NO 2 sensing properties, Meas. Sci. Technol. 28 (2017) 54005. doi:10.1088/1361-6501/aa57e7.
  • [12] K. Dunst, J. Karczewski, P. Jasiński, Nitrogen dioxide sensing properties of PEDOT polymer films, Sensors Actuators B Chem. 247 (2017) 108–113. doi:10.1016/j.snb.2017.03.003.
  • [13] K.C. Persaud, Polymers for chemical sensing, Mater. Today. 8 (2005) 38–44. doi:10.1016/S1369-7021(05)00793-5.
  • [14] J. Zhang, X.S. Zhao, Conducting Polymers Directly Coated on Reduced Graphene Oxide Sheets as High-Performance Supercapacitor Electrodes, J. Phys. Chem. C. 116 (2012) 5420–5426. doi:10.1021/jp211474e.
  • [15] D.-W. Wang, F. Li, J. Zhao, W. Ren, Z.-G. Chen, J. Tan, Z.-S. Wu, I. Gentle, G.Q. Lu, H.- M. Cheng, Fabrication of Graphene/Polyaniline Composite Paper via In Situ Anodic Electropolymerization for High-Performance Flexible Electrode, (2009). doi:10.1021/NN900297M.
  • [16] T.K. Das, S. Prusty, Graphene-Based Polymer Composites and Their Applications, Polym. Plast. Technol. Eng. 52 (2013) 319–331. doi:10.1080/03602559.2012.751410.
  • [17] Y. Yang, S. Li, W. Yang, W. Yuan, J. Xu, Y. Jiang, In situ polymerization deposition of porous conducting polymer on reduced graphene oxide for gas sensor., ACS Appl. Mater. Interfaces. 6 (2014) 13807–14. doi:10.1021/am5032456.
  • [18] I. Jung, D. Dikin, S. Park, W. Cai, S.L. Mielke, R.S. Ruoff, Effect of Water Vapor on Electrical Properties of Individual Reduced Graphene Oxide Sheets, J. Phys. Chem. C. 112 (2008) 20264–20268. doi:10.1021/jp807525d.
  • [19] G. Lu, L.E. Ocola, J. Chen, Gas detection using low-temperature reduced graphene oxide sheets, Appl. Phys. Lett. 94 (2009) 2007–2010. doi:10.1063/1.3086896.
  • [20] K.J. Dunst, P. Jasiński, Graphene oxide, reduced graphene oxide and composite thin films NO 2 sensing properties, (2016) 101610S. doi:10.1117/12.2246761.
  • [21] J.T. Robinson, F.K. Perkins, E.S. Snow, Z. Wei, P.E. Sheehan, Reduced Graphene Oxide Molecular Sensors, Nano Lett. 8 (2008) 3137–3140. doi:10.1021/nl8013007.
  • [22] T. Patois, J.-B. Sanchez, F. Berger, J.-Y. Rauch, P. Fievet, B. Lakard, Ammonia gas sensors based on polypyrrole films: Influence of electrodeposition parameters, Sensors Actuators B Chem. 171–172 (2012) 431–439. doi:10.1016/j.snb.2012.05.005.
  • [23] S. Carquigny, O. Segut, B. Lakard, F. Lallemand, P. Fievet, Effect of electrolyte solvent on the morphology of polypyrrole films: Application to the use of polypyrrole in pH sensors, Synth. Met. 158 (2008) 453–461. doi:10.1016/j.synthmet.2008.03.010.