Dental personnel manually handle methacrylate-based restorative materials, which can cause skin irritation and allergies. The protection given by different types of medical gloves is not well known. Breakthrough time (BTT, min) was used as a measure of protection according to a European standard, using 2 test mixtures consisting of respectively 3 and 5 monomers. Fourteen gloves representing natural rubber latex, synthetic rubber, and synthetic polymeric material were tested. The BTT ranged from some minutes to more than 2 hrs for the 4 monomers with a molecular mass less than 300. The longest protection was recorded for Nitra Touch (nitrile rubber), Tactylon (synthetic rubber), and Metin (PVC).
Rocznik
Strony
497--509
Opis fizyczny
Bibliogr. 34 poz., rys., tab.
Twórcy
  • Department of Human Work Science, Lulea University of Technology, Lulea, Sweden
  • Scandinavian Institute of Dental Materials (NIOM), Haslum, Norway
autor
  • Scandinavian Institute of Dental Materials (NIOM), Haslum, Norway
Bibliografia
  • 1.Burke, F.J., Wilson, NH., & Cheung, S.W. (1995). Factors associated with skin irritation of the hands experienced by general dental practitioners. Contact Dermatitis, 32(1), 35-38.
  • 2.European Committee for Standardization. (1994). Protective gloves against chemicals and micro-organisms, Part 3: Determination of resistance to permeation by chemicals (Standard No. EN 374-3:1994). Brussels, Belgium: Author.
  • 3.Heese, A., Peters, K.P., Stahl, J., Koch, H.U., & Hornstein, O.P. (1995). Incidence and increase in type I allergies to rubber gloves in dental medical students. Hautarzt, 46(1), 15-21.
  • 4.Hill, J.G., Grimwood, R.E., Hermesch, C.B., & Marks, J.G., Jr. (1998). Prevalence of occupational related hand dermatitis in dental workers. Journal of American Dental Association, 129(2), 212-217.
  • 5.International Organization for Standardization (ISO). (1987). Water for analytic laboratory use. Specification and test methods (Standard No. ISO 3696:1987). Geneva, Switzerland: Author.
  • 6.International Organization for Standardization (ISO). (1991). Rubber vulcanized or thermoplastic-determination of dimensions of test pieces and products for test purpose (Standard No. ISO 4648:1991). Geneva, Switzerland: Author.
  • 7.Jacobsen, N., Derand, T., & Hensten-Pettersen, A. (1996). Profile of work-related health complaints among Swedish dental technicians. Community Dentistry and Oral Epidemiology, 24, 138-144.
  • 8.Jolanki, R., Kanerva, L., & Estlander, T. (1995). Occupational allergic contact dermatitis caused by epoxy dimethacrylate in ultraviolet-light-cured paints, and Bisphenol A in dental composite resin. Contact Dermatitis, 33(2), 94-99.
  • 9.Jolanki, R., Kanerva, L., & Estlander, T. (1996). Allergic patch test reaction to diglycidyl ether of Bisphenol A in hardened nail base and topcoat. Contact Dermatitis, 35(4), 246-247.
  • 10.Kanerva, L., Estlander, T., & Jolanki, R. (1997). Occupational allergic contact dermatitis caused by acrylic tri-cure glass ionomers. Contact Dermatitis, 37, 49-50.
  • 11.Kanerva, L., Estlander, T., Jolanki, R., & Henriks-Eckerman, M.-L. (1995a). Allergy caused by acrylate compounds at the Finnish Institute of Occupational Health (FIOH) 1975-1995. In Proceedings of Sixth FIOH-NIOSH Joint Symposium on Occupational Health and Safety (pp. 128-134; People and Work; Research Reports, 3). Helsinki, Finland: Finnish Institute of Occupational Health.
  • 12.Kanerva, L., Jolanki, R., Leino, T., & Estlander, T. (1995b). Occupational allergic contact dermatitis from 2-hydroxyethyl methacrylate and ethylene glycol dimethacrylate in a modified structural adhesive. Contact Dermatitis, 33(2), 84-89.
  • 13.Kanerva, L., Lauerma, A., Estlander, T., & Alanko, K. (1996). Occupational allergic contact dermatitis caused by photo bonded sculptured nails and a review of (meth)acrylates in nail cosmetics. American Journal of Contact Dermatitis, 7(2), 109-115.
  • 14.Kanerva, L., Mikola, H., Henriks-Eckerman, M.-L., Jolanki, R., & Estlander, T. (1998). Fingertip paresthesia and occupational allergic contact dermatitis caused by acrylics in a dental nurse. Contact Dermatitis, 38(2), 114-116.
  • 15.Lönnroth, E.-C., & Shahnavaz, H. (1998a). Adverse reaction in skin, eyes, and respiratory tract among dental personnel in Sweden. Swedish Dental Journal, 22(1-2), 33-45.
  • 16.Lönnroth, E.-C., & Shahnavaz, H. (1998b). Atopic dermatitis, conjunctivitis, and hand dermatitis among Swedish dental personnel, including use of personnel protective devices. Swedish Dental Journal, 22(3), 105-115.
  • 17.Lönnroth, E.-C., & Shahnavaz, H. (1998c). Hand dermatitis and symptoms from the fingers among Swedish dental personnel. Swedish Dental Journal, 22(1-2), 23-32.
  • 18.Lönnroth, E.-C., Wellendorf, H., & Ruyter, I.E. (2002). Permeability of different types of protective gloves to MMA, EGDMA, and 1,4 BUDMA. Manuscript submitted for publication.
  • 19.Mellström, G.A., Wrangsjö, K., Wahlberg, J.E., & Fryklund, B. (1996). The value and limitations of protective gloves in medical health service, Part III. Dermatology nursing, 8, 345-355.
  • 20.Munksgaard, E.C. (1992). Permeability of protective gloves to (di) methacrylates in resinous dental materials, Scandinavian Journal of Dental Research, 100, 189-192.
  • 21.Munksgaard, E.C., Hansen, E.K., Engen, T., & Holm, U. (1996). Self-reported occupational dermatological reactions among Danish dentists. European Journal of Oral Science, 104(4), 396-402.
  • 22.Mürer, A.J., Poulsen, O.M., Roed-Petersen, J., & Tüchsen, F. (1995). Skin problem among Danish dental technicians. A cross-sectional study. Contact Dermatitis, 33(1), 42-47.
  • 23.Pirila, P., Kanerva, L., Keskinen, H., Estlander, T., Hytonen, M., Tupparainen, M., et al. (1998). Occupational respiratory hypersensitivity caused by preparations containing acrylates in dental personnel. Clinical and Experimental Allergy, 28, 1404-1411.
  • 24.Rustemeyer, T., & Frosch, P.J. (1996). Occupational skin diseases in dental laboratory technicians (1). Clinical picture and essential factors. Contact Dermatitis, 34(2), 125-133.
  • 25.Ruyter, I.E. (1982). Monomer systems and polymerization. In G. Vanherle & D.C. Smith (Eds.), International Symposium on Posterior Composite Resin Dental Restorative Materials: Vol. 61: Dental research (pp. 108-137). St. Paul, MN, USA: Dental Products Division, 3M Company.
  • 26.Ruyter, I.E. (1995). Physical and chemical aspects related to substances released from polymeric materials in aqueous environment. Advances in Dental Research, 9(4), 344-347.
  • 27.Ruyter, I.E., & Øysæd, H. (1987). Composites for use in posterior teeth: Composition and conversation. Journal of Biomedical Research, 21, 11-23.
  • 28.Ruyter, I.E, & Øysæd, H. (1988). Analysis and characterisation of dental polymers. CRC Critical Reviews in Biocompatibility, 4(3), 247-279.
  • 29.Ruyter, I.E, & Sjøvik, I.J. (1981). Composition of dental resin and composite materials. Acta Odontologica Scandinavica, 39, 133-146.
  • 30.Ruyter, I.E, & Sjøvik Kleven, I.J. (1987). Monomers and filler content of resin-based crown and bridge materials. Dental Materials, 3, 315-321.
  • 31.Savonius, B., Keskinen, H., Tupparainen, M., & Kanerva, L. (1993). Occupational respiratory disease caused by acrylates. Clinical and Experimental Allergy, 23, 416-424.
  • 32.Tarlo, S.M., Sussman, G.L., & Holness, D.L. (1997). Latex sensitivity in dental students and staff: a cross-sectional study. Journal of Allergy and Clinical Immunology, 99(3), 396-401.
  • 33.Taylor, J.S., & Praditsuwan, P. (1996). Latex allergy. Review of 44 cases including outcome and frequent association with allergic hand eczema. Archives of Dermatology, 132(3), 265-271.
  • 34.Uveges, R.E., Grimwood, R.E., Slawsky, L.D., & Marks, J.G., Jr. (1995). Epidemiology of hand dermatitis in dental personnel. Military Medicine, 160(7), 335-338.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-7f875352-68ae-4054-b30e-b4913d6ee075
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.