PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Thermodynamic processes involving liquefied natural gas at the LNG receiving terminals

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Procesy termodynamiczne z wykorzystaniem skroplonego gazu ziemnego w terminalach odbiorczych LNG
Języki publikacji
EN
Abstrakty
EN
The increase in demand for natural gas in the world, cause that the production of liquefied natural gas (LNG) and in consequences its regasification becoming more common process related to its transportation. Liquefied gas is transported in the tanks at a temperature of about 111K at atmospheric pressure. The process required to convert LNG from a liquid to a gas phase for further pipeline transport, allows the use of exergy of LNG to various applications, including for electricity generation. Exergy analysis is a well known technique for analyzing irreversible losses in a separate process. It allows to specify the distribution, the source and size of the irreversible losses in energy systems, and thus provide guidelines for energy efficiency. Because both the LNG regasification and liquefaction of natural gas are energy intensive, exergy analysis process is essential for designing highly efficient cryogenic installations.
PL
Wzrost zapotrzebowania na gaz ziemny na świecie powoduje, że produkcja skroplonego gazu ziemnego (LNG), a w konsekwencji jego regazyfikacja, staje się coraz bardziej powszechnym procesem związanym z jego transportem. Skroplony gaz transportowany jest w zbiornikach w temperaturze około 111K pod ciśnieniem atmosferycznym. Przebieg procesu regazyfikacji niezbędny do zamiany LNG z fazy ciekłej w gazową dla dalszego transportu w sieci, umożliwia wykorzystanie egzergii LNG do różnych zastosowań, między innymi do produkcji energii elektrycznej. Analiza egzergii jest znaną techniką analizowania nieodwracalnych strat w wydzielonym procesie. Pozwala na określenie dystrybucji, źródła i wielkości nieodwracalnych strat w systemach energetycznych, a więc ustalić wytyczne dotyczące efektywnego zużycia energii. Ponieważ zarówno regazyfikacja LNG jak i skraplanie gazu ziemnego są energochłonne, proces analizy egzergii jest niezbędny do projektowania wysoce wydajnych instalacji kriogenicznych.
Rocznik
Strony
349--359
Opis fizyczny
Bibliogr. 23 poz., tab., wykr.
Twórcy
autor
  • AGH University of Science and Technology, Faculty of Drilling, Oil and Gas, Al. Mickiewicza 30, 30-059 Kraków, Poland
Bibliografia
  • Alabdulkarem A., Mortazavi A., Hwang Y., Radermergher R., Rogers P., 2011. Optimization of propane pre-cooled mixedrefrigerant LNG plant. Applied Thermal Engineering, 31.
  • Dispenza C., Dispenza G., La Rocca V., Panno G., 2009. Exergy recovery in regasification facilities - Cold utilization:a modular unit. Applied Thermal Engineering, 29.
  • Dispenza C., Dispenza G., La Rocca V., Panno G., 2009. Exergy recovery during LNG regasification: electric energyproduction - Part one. Applied Thermal Engineering, 29.
  • Dispenza C., Dispenza G., La Rocca V., Panno G., 2009. Exergy recovery during LNG regasification: electric energyproduction - Part two. Applied Thermal Engineering, 29.
  • Hisazumi Y., Yamasaki Y., Sugiyama S., 1998. Proposal for a high efficiency LNG power-generation system utilizingwaste heat from the combined cycle. Applied Energy, 60.
  • Liu H., You L., 1999. Characteristics and applications of the cold heat exergy of liquefied natural gas. Energy Conversion & Management, 40.
  • Liu Y., Guo K., 2011. A novel cryogenic power cycle for LNG cold energy recovery. Energy, 36.
  • Łaciak M., 2011. Problemy techniczne i technologiczne eksploatacji terminali rozładunkowych LNG. Zeszyty Nauk. AGH, Tom 28 (4).
  • Łaciak M., 2012. Properties of Artificial Gaseous Mixtures for Their Safe Use and Support the Natural Gas SupplyNetworks. Arch. Min. Sci., Vol. 57. No. 2, p. 351-362.
  • Łaciak M., Nagy S., 2010. Problemy bezpieczeństwa technicznego i charakterystyka zagrożeń związanych z terminalemrozładunkowym LNG. Zeszyty Nauk. AGH, Tom 27 (4).
  • Olivetti G., Arcuri N., Bruno R., Simone M., 2012. A rational thermodynamic use of liquefied natural gas in a wasteincinerator plant. Applied Thermal Engineering, 35.
  • Qiang W., Yanzhong L., Jiang W., 2004. Analysis of power cycle based on cold energy of liquefied natural gas and lowgradeheat source. Applied Thermal Engineering, 24.
  • Remeljej C.W., Hoadley A.F.A., 2006. An exergy analysis of small-scale liquefied natural gas (LNG) liquefactionprocesses. Energy, 31.
  • Shi X., Che D.2009. A combined power cycle utilizing low-temperature waste heat and LNG cold energy. Energy Conversion & Management, 50. Siemek J., Nagy S., 2012. Energy Carriers Use in the World: Natural Gas - Conventional and Unconventional GasResources. Arch. Min. Sci., Vol. 57. No 2, p. 283-312.
  • Szargut J., Szczygieł I., 2009. Utilization of the cryogenic exergy of liquid natural gas (LNG) for the production ofelectricity. Energy, 34.
  • Vitale S.A., 2012. LNG and Gas Thermodynamics. Vol. II. GTI.
  • Yang C.C., Huang Z., 2004. Lower Emission LNG Vaporization. LNG Journal Nov./Dec. 2004.
  • Zhang N., Lior N., 2006. A novel near-zero CO2 emission thermal cycle with LNG cryogenic exergy utilization. Energy, 31.
  • Applied LNG Technologies, http://www.altlngusa.com/ngf_lng.htm
  • BG Group, http://www.bg-group.com/group/LNG_2001.htm
  • CH-IV, http://www.ch-iv.com/lng/lngfact.htm
  • Chive Fuels, http://www.lng-cng.com/chivefuels/liquefiednaturalgas.htm
  • PN-EN 1473:2007: Instalacje i urządzenia do skroplonego gazu ziemnego, projektowanie instalacji lądowych.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-7ed6a43b-0847-4a4b-9658-d0da62879247
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.