Tytuł artykułu
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
The thermal environment in the workplace is an important factor which affects workers’ health. During 2011 in Poland, 14,781 workers were exposed to a cold working environment, i.e., 3.8% of persons employed in hazardous work conditions. The aim of this study was to determine the cardiovascular response to continuous (4 °C for 60 min) and intermittent (10 min at 4 °C and 10 min at room temperature alternately) exposure to the cold in 30 healthy men aged 20–27 years. Peripheral blood flow was assessed with impedance plethysmography. Heart rate and arterial blood pressure were monitored with the Holter system. Having assessed the results, it is difficult to say which kind of exposure has a more severe impact on the cardiovascular system. Longer observation and a more detailed analysis would be necessary (e.g., Doppler echocardiography).
Wydawca
Rocznik
Tom
Strony
501--507
Opis fizyczny
Bibliogr. 24 poz., tab.
Twórcy
autor
- Central Institute for Labour Protection - National Research Institute (CIOP-PIB), Poland
autor
- Central Institute for Labour Protection - National Research Institute (CIOP-PIB), Poland
autor
- Medical University of Łódź, Poland
Bibliografia
- 1. Marszałek A. Zimne środowisko - sposoby zabezpieczenia organizmu człowieka przed oddziaływaniem zimna [A cold environment – its specificity and ways of protecting the human body against the adverse effects of the cold]. Bezpieczeństwo Pracy. 2011;(10):18-21.
- 2. Główny Urząd Statystyczny (GUS). Warunki pracy w 2011 [Working conditions in 2011]. Warszawa: GUS; 2012.
- 3. Raven PB, Wilkerson JE, Horvath SM, et al. Thermal, metabolic, and cardiovascular responses to various degrees of cold stress. Can J Physiol Pharmacol. 1975;53(2):293-298. 10.1139/y75-041
- 4. Chiu DT, Cheng KK. Circulatory changes in cold-acclimation and cold stress. Clin Exp Pharmacol Physiol. 1976;3(5):449-452. 10.1111/j.1440-1681.1976.tb00622.x
- 5. Shepherd JT, Rusch NJ, Vanhoutte PM. Effect of cold on the blood vessel wall. Gen Pharmacol. 1983;14(1):61-64. doi:10.1016/0306-3623(83)90064-2.
- 6. Tanaka S, Konno A, Hashimoto A, et al. The influence of cold temperatures on the progression of hypertension: an epidemiological study. J Hypertens Suppl. 1989;7(1):S49-S51. doi:10.1097/00004872-198902001-00015.
- 7. Hanna JM. Climate, altitude, and blood pressure. Hum Biol. 1999;71(4):553-82. Review.
- 8. Postolache T, Gautier S, Laloux B, et al. Positive correlation between the blood pressure and heart rate response to the cold pressor test and the environmental temperature in older hypertensives. Am J Hypertens. 1993;6(5):376–381.
- 9. Kim JY, Jung KY, Hong YS, et al. The relationship between cold exposure and hypertension. J Occup Health. 2003;45(5):300–306. doi:10.1539/joh.45.300.
- 10. Siebert J, Polinski A, Rogowski J. Pletyzmografia impedancyjna-ocena całkowitego przepływu krwi w przedramieniu [Impedance plethysmography - the global evaluation of the blood flow in the forearm]. Folia Cardiologica. 1999;6(4):359-362.
- 11. Siebert J, Poliński A. Badania modelowe zastosowania pletyzmografii impedacyjnej do badania przepływu w kończynach [Application of impedance plethysmograpy in blood flow in limbs examination - model studies]. Folia Cardiologica. 1999;6(4):417-422.
- 12. Neubauer-Geryk J, Bieniaszewski L. Metody oceny funkcji naczyń-pletyzmografia [Methods of vessels function examination - plethysmography]. Choroby serca i naczyń. 2009;6(4):184-187.
- 13. Green S, Thorp R, Reeder EJ, et al. Venous occlusion plethysmography versus Doppler ultrasound in the assessment of leg blood flow during calf exercise. Eur J Appl Physiol. 2011;111(8):1889-900. 10.1007/s00421-010-1819-6
- 14. Shariati NH, Zahedi E, Jajai HM. Classification of vascular function in upper limb using bilateral photoplethysmographic signals. Physiol Meas. 2008;29(3):365-374. doi:10.1088/0967-3334/29/3/007.
- 15. Tsai WC, Chen JY, Wang MC, et al. Association of risk factors with increased pulse wave velocity detected by a novel method using dual-channel photoplethysmography. Am J Hypertens. 2005;18(8):1118-1122. 10.1016/j.amjhyper.2005.03.739
- 16. Ohgi S, Moore DJ, Miles RD, et al. Physiology of the peaked finger pulse in normal and cold-sensitive subjects. J Vasc Surg. 1986;3(3):516-522. 10.1016/0741-5214(86)90119-9
- 17. Karunakara RG, Lephart SM, Pincivero DM. Changes in forearm blood flow during single and intermittent cold application. J Orthop Sports Phys Ther. 1999;29(3):177-180. doi:10.2519/jospt.1999.29.3.177.
- 18. Weston M, Taber C, Casagranda L, et al. Changes in local blood volume during cold gel pack application to traumatizied ankles. J Orthop Sports Phys Ther. 1994;19(4):197-199. doi:10.2519/jospt.1994.19.4.197.
- 19. Koradecka D. Wpływ czynników związanych z pracą typowym narzędziem wibracyjnym na obwodowe krążenie krwi [The influence of work with typical vibration tool on peripheral blood flow]. Warszawa: CIOP; 1980.
- 20. Chemiack M, Clive J, Seider A. Vibration exposure, smoking, and vascular dysfunction. Occup Environ Med. 2000;57(5):341-347. doi:10.1136/oem.57.5.341.
- 21. House R, Jiang D, Thompson A, et al. Vasospasm in the feet in workers assessed for HAVS. Occup Med (Lond). 2011;61(2):115-120. 10.1093/occmed/kqq191
- 22. Thompson A, House R, Manno M. Assessment of the hand-arm vibration syndrome: thermometry, plethysmography and Stockholm Working Scale. Occup Med (Lond). 2007;(7):512-517. 10.1093/occmed/kqm076
- 23. Frey MA, Siervogel RM, Selm EA, et al. Cardiovascular response to cooling of limbs determined by noninvasive methods. Eur J Appl Physiol Occup Physiol. 1980;44(1):67-75. doi:10.1007/BF00421765.
- 24. Jay O, Havenith GA. Skin cooling on contact with cold materials: the effect of blood flow during short-term exposures. Ann Occup Hyg. 2004;48(2):129-137. 10.1093/annhyg/meh00
Uwagi
PL
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-7a837ad7-9b34-4ff2-a122-9cd9c035ad3d
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.