PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Influence of the internal electrolyte composition on amperometric sulphur dioxide sensor properties

Identyfikatory
Warianty tytułu
PL
Wpływ składu elektrolitu wewnętrznego na właściwości metrologiczne amperometrycznego czujnika dwutlenku siarki
Konferencja
International Microelectronics and Packaging IMAPS-CPMT Poland Conference (37 ; 22-25.09.2013 ; Kraków, Polska)
Języki publikacji
EN
Abstrakty
EN
In this work investigation of an amperometric sulphur dioxide sensor with a liquid electrolyte, a mercury sulphate reference electrode and solid polymer electrolyte (Nafion) covered with gold as a working electrode properties is presented. The main goal of this research is to determine the influence of internal electrolyte composition on the sensor properties. Sensor filled with 1M and 5M sulphuric acid has been studied.
PL
W tej pracy przedstawiono wyniki badań amperometrycznego czujnika dwutlenku siarki z ciekłym elektrolitem, siarczanortęciową elektrodę odniesienia oraz elektrodę roboczą w postaci membrany wykonanej z polimerowego elektrolitu stałego (Nafionu) pokrytej złotem. Głównym celem przedstawionych badań było określenie wpływu składu elektrolitu wewnętrznego na właściwości czujnika. Przebadano czujnik wypełniony 1M i 5M kwasem siarkowym.
Rocznik
Strony
23--26
Opis fizyczny
Bibliogr. 9 poz., wykr., tab.
Twórcy
  • Politechnika Gdańska, Katedra Inżynierii Chemicznej i Procesowej, Wydział Chemiczny
autor
  • Politechnika Gdańska, Katedra Inżynierii Biomedycznej, Wydział Elektroniki, Telekomunikacji i Informatyki
  • Politechnika Gdańska, Katedra Inżynierii Chemicznej i Procesowej, Wydział Chemiczny
Bibliografia
  • [1] Bontempelli G., Comisso N., Toniolo R., Schiavon G., „Electroanalytical sensors for nonconducting media based on electrodes supported on perfiuorinated ion-exchange membranes”, Electroanalysis, 9 (1997) 433.
  • [2] Schiavon G., Zotti G., Toniolo R., Bontempelli G., „Amperometric monitoring of sulphur dioxide in liquid and air samples of low conductivity by electrodes supported on ion-exchange membranes”, Analyst., 116 (1991) 797.
  • [3] Chiou C.Y., Chou Т.C., „Amperometric SO2 gas sensors based on solid polymer electrolytes”, Sens. Actuators B, 87 (2002) 1.
  • [4] Hodgson A.W.E., Jacquinot P., Hauser P.C., „Electrochemical Sensor for the Detection of SO2 in the Low-ppb Range”, Anal. Chem., 71 (1999) 2831.
  • [5] Chachulski В., Gębicki J., „Influence of Aprotic Solvent on Selectivity of an Amperometric Sensor with Nafion Membrane”, Electroanalysis, 18 (2005) 433.
  • [6] Gebicki J., Chachulski B., „Metrological parameters of sulphur dioxide amperometric sensor containing addition of aprotic solvents”, Sens. Actuators B, 141 (2006) 249.
  • [7] Jacquinot P., Hodgson A.W.E., Hauser P.C., „Amperometric detection of NO and NO2 in the ppb range with solid-polymer electrolyte membrane supported noble metal electrodes", Anal. Chim. Acta, 443 (2001) 53.
  • [8] Gebicki J., Chachulski B., „Impedance Investigations of Amperometric Gas Sensor Containing Aprotic Solvent”, Elecroanalysis, 18 (2006) 2413.
  • [9] Takenaka H., Torikai E., „Production of an ion-exchange membrane-catalytic electrode bonded material for electrolytic cells”, Japan Patent No. 55-38934, Tokyo 1980, Japan, 147.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-7a658f16-f3e1-42c2-a17c-576535b96ab9
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.