PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Recent advances in medical ultrasound

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
Proceedings of the 2 nd EAA International Symposium on Hydroacoustics 24-27 May 1999, Gdańsk-Jurata POLAND
Języki publikacji
EN
Abstrakty
EN
Imaging and Doppler ultrasounds creatively employing recent radar and sonar technologies are rapidly growing with numerous new exciting developments. Velocity sensing techniques can be as simple as C.W. Doppler up to the multi-channel MTL High density, multi-elements linear array, phase array and annular array transducers benefit from the synthetic aperture and open a new era of a real time scanning of the biological structures with unprecedented quality. Flow velocity color mapping, power Doppler, tissue Doppler, contrast agents echo enhancement and other new, exciting developments will be discussed.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
319--324
Opis fizyczny
Bibliogr. 17 poz., rys.
Twórcy
autor
  • Institute of Fundamental Technological Research - Polish Academy of Scienees, Świętokrzyska 21,00-049 Warsaw, Poland
Bibliografia
  • 1. A.I. Anderson, LD.Hampton.Acoustics of gas-bearing sediments, J.Acoust.Soc.Am., 67, pp. 1865-1889, (1980).
  • 2. N. Bom, C.T. Lancee, F. van Zwieten, E. Kloster, J.R. Roelandt, Multisam. echocardigraphy, In: Technical description, Circulation,48, pp.1066,(1973).
  • 3. P.R Chang and K.K. Shung, Second harmonic imaging and harmonic Doppler measuraments with Albunex., IEEE Transactions of Ultrasonic, Ferroelectrics and Frequency Control UFFC,pp. 1020-1027,(1995).
  • 4. C.C. Church, The effects of an elastic solid surface layer on the radial pulsation of gas bubbles.J. Acoust. Soc.Am. 97(3),(1995).
  • 5. N. De Jong N, F.J. Ten Cate, C.T. Lancce,J.R. Roelandt, N. Born, Principles and recent developments in ultrasound contrast agents. Ultrasonics 29: pp.324-330,(1991).
  • 6. S. Freeman, P.C. Li, M. O'Donnell, Retrospective dynamic transmit Cocusing, Ultrasonic Imaging, 17,pp.173-196,(1996).
  • 7. R. Gramiak R.and P.M. Shah, Echocardiography of the aortic root. Invest.Radiol.,3, pp.356-366,(1968).
  • 8. J.Y. Lu, R Zoo, J.F. Greenleaf Biomedical ultrasound beam forming, UItrasound in Medicine and Biology, 20, 5, pp.403-428, (1994).
  • 9. W.N. McDicken, G.R. Sutherland, C.R. Moran, L. Gordon, Color Doppler velocity imaging of the myocardium, Ultrasound in Med. and Biology, 18:651-654;(1992).
  • 10. K. Mlosek, A. Nowicki,E. Szymańska, W. Jakubowski, W. Secomski, P. Karłowicz. J. Litniewski, M. Lewandowski, Ultrasound system for microsonography of the skin: instrumentation and clinical application (in polish), Ultrasonografia,2,67-76, (1998).
  • 11. Nowicki, J.M. Reid, An infinite gate pulse Doppler, Ultrasound in medicine and Biology, 7, pp.41-SO, (1981).
  • 12. Nowicki,J.M. Reid,P. Pedersen,A.W. Schmidt R Oung, On the behavior of instantaneous frequency estimators implemented on Doppler Baw imagers, Ultrasound in Medicine and Biology,vol.16, pp.511-518,(1990). 324
  • 13. Nowicki, R. Olszewski. J. Etienne. P. Karłowicz, J. Adamus, Assessment of Wall Velocity Gradient Imaging using Test-Phantom, Ultrasound in Medicine and Biology, 22,9, 1255-1260, (1996).
  • 14. D.R Simpson, P.N. Burns, Pulse inversion Doppler: a new method for detecting nonlinear echoes from microbubble contrast agents, Proc. 1997 IEEE Ultrasonic Symposium, p.1597- 1600,(1997).
  • 15. J.C. Somer, Principles of phased array, Archives of Acoustics, 17, 1, pp.133-150, (1992).
  • 16. G.R. Sutherland,M. Stewart, K. Groundstroem et al., Color Doppler myocardial imaging: a new technique for the assessment of myocardial function, J.Am.Soc. Echocardigraphy, 7: 441- 458; (1994).
  • 17. J.C. Willemetz, A. Nowic:ki,J.J. Meister, Bias and variance on the estimate of the Doppler frequency induced by wall motion filter, Ultrasound Imaging, vol.11, pp.215-225, (1989).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-74780619-b0b2-4e3e-b476-04bc954a508c
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.