PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The role of friction in the mechanism of retaining the partial removable dentures with double crown system

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Cylindrical telescopic crowns belong to bolt dentures, because their adhesion strength is based on the friction force. The magnitude of static and slide friction forces depends on the strain within the contact area and properties of materials employed. Friction force value between telescope elements declines in the first phase of wearing period and, subsequently, maintains particular constant value of 8 to 10 N. In the telescopic technique, homo and heterogenic joints are used. The following prosthodontic materials have been examined: goldbase alloys (Degudent Kiss, Degulor M), cobalt-base alloy (Brealloy 270), ceramics (Zircon Oxide, Zirconia) during tribological investigations on FGP composite resin. The cooperating surfaces were moistened with synthetic saliva. The research confirmed the dependence of the static friction coefficient on the contact pressure for the analyzed pairs of materials used in prosthodontics. The biggest effect of the contact pressure on the coefficient of friction value occurs when the ceramic rubs on FGP composite resin. The most stable friction coefficient in the context of contact pressure changes as well as life has been found in the case of the cobalt alloy Brealloy 270. An interesting material is a gold alloy Degulor M, for which the coefficient of friction varies only slightly with pressure in the range of 0.6 to 0.9 MPa.
Rocznik
Strony
43--48
Opis fizyczny
Bibliogr. 17 poz., rys., wykr.
Twórcy
autor
  • Silesian Piasts University of Medicine in Wrocław, Wrocław, Poland
  • Wrocław University of Technology, Faculty of Mechanical Engineering, Wrocław, Poland
autor
  • Wrocław University of Technology, Faculty of Mechanical Engineering, Wrocław, Poland
Bibliografia
  • [1] BESCHNIDT S.M., CHITMONGKOLSUK S., PRULL R., Telescopic crown-retained removable partial dentures: review and case report, Compend. Contin. Educ. Dent., 2001, Vol. 22, 927–934.
  • [2] BEUER F., EDELHOFF D., GERNET W., NAUMANN M., Parameters affecting retentive force of electroformed doublecrown systems, Clin. Oral Invest., 2010, Vol. 14, 129–135.
  • [3] DABROWA T., PLAWSKI A., Possibilities of prosthodontics treatment with removable partial dentures and telescopic double crowns system, Dent. Med. Probl., 2011, Vol. 48(1), 97–102.
  • [4] EITNER S., SCHLEGEL A., EMSKA N., HOLST S., WILL J., HAMEL J., Comparing bar and double-crown attachments in implant-retained prosthetic reconstruction; a follow-up investigation, Clin. Oral Implants. Res., 2008, Vol. 19, 530–537.
  • [5] GERNET W., ADAM P., REITHER W., Nachuntersuchungen von Teilprothesen mit Konuskronen nach K.H. Körber, Dtsch. Zahnärztl. Z., 1983, Vol. 38, 998–1001.
  • [6] GROSSMAN A.CH., HASSEL J., SHILLING O., LEHMAN F., KOOB A., RAMMELSBERG P., Treatment with double crownretained removable partial dentures and oral health-related quality of life in middle and high-aged patients, Int. J. Prosthodont., 2007, Vol. 20, 576–578.
  • [7] MANES F.J.F., MARTINEM G.A., OTEIZA G.B., BOUAZZA J.K., BENET I.F., CANDEL T., A telescopic crowns in adult case with lip and palate cleft. Update on the etiology and management, Med. Oral Patol. Oral Cir. Bucal., 2006, Vol. 11, 358–362.
  • [8] SASSEN H., Functional parameters and occlusion of partial dentures as a function of the type of attachment, Dtsch. Zahnärztl. Z., 1990, Vol. 10, 576–578.
  • [9] YAMAUCHI E., Case report of cone crown telescopic denture for bilateral lower free and missing, Nihon Hotetsu Shika Gakkai Zasshi, 2008, Vol. 52, 556–559.
  • [10] COCA I., LOTZMANN U., PÖGGELER R., Long-term experience with telescopically retained overdentures (double crown technique), Eur. J. Prosthodont. Restor. Dent., 2000, Vol. 8, 33–37.
  • [11] DĄBROWA T., PANEK H., NAPADŁEK P., 8-year clinical observation of telescopic anchors applied in removable dentures – case report, Dent. Med. Probl., 2007, Vol. 44(4), 521–525.
  • [12] WENZ H.J., HERTRAMPF K., LEHMANN K.M., Clinical longevity of removable partial dentures retained by telescopic crowns: outcome of the double crown with clearance fit, Int. J. Prosthodont., 2001, Vol. 14, 207–213.
  • [13] WIELEBA W., KOWALEWSKI P., Device for testing friction in rolling-sliding motion, Patent Application P.382893. [14] WÖSTMANN B., BALKENHOL M., WEBER A., FERGER P., REHMANN P., Long-term analysis of telescopic crown retained removable partial dentures: survival and need for maintance. J. Dent., 2007, Vol. 35, 939–945.
  • [15] BUSHAN B., Modern tribology handbook, CRC Press, Boca Raton, Florida, 2001.
  • [16] LAWROWSKI Z., Tribology. Friction, wear and lubrication, Wrocław University of Technology Publishing House, Wrocław, 2008.
  • [17] MENGEL R., KREUZER G., LEHMAN K.L., FLORES-DE-JACOBY L., A telescopic crown concept for the restoration of partially edentolous patients with aggressive generalized periodontitis: A 3-year prospective longitudinal study, Int. J. Periodontics Restorative Dent., 2007, Vol. 27, 231–239.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-731cd369-ed71-4bc1-92dd-cbec7c995215
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.