The defect analysis of Inconel 738LC with computed tomography inspection

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In the present paper, computed tomography (CT) inspection is shown. The CT inspection method allowed to rate the density of defects hidden inside a material, which has a significant role in the live material. The method allows to evaluate the reliability of tensile test’s results. In our analysis, the position of crack propagation was determined by CT, and the tensile test was performed to check the accuracy of the nondestructive method. The tensile tests were performed on Inconel 738LC [1] samples.
Rocznik
Strony
80--83
Opis fizyczny
Bibliogr. 5 poz., rys., wykr.
Twórcy
  • Material and Measurment Laboratory at Rzeszów Technical Center, BorgWarner Poland Sp. z o.o. Jasionka 950A, 36-001 Jasionka, Poland
  • Core Sience Materials Development at Rzeszów Technical Center, BorgWarner Poland Sp. z o.o. Jasionka 950A, 36-001 Jasionka, Poland
  • Faculty of Mechanical Engineering and Aeronautics, Rzeszow University of Technology, al. Powstańców Warszawy 12, 35-959 Rzeszów, Poland
Bibliografia
  • [1] S. Pospisilova, T. Podrabsky, K. Stransky: Heterogenity of Inconel 713 LC and Inconel 738 LC, 10th International Research/Expert Conference “Trends in the Development of Machinery and Associated Technology“ TMT 2006, Barcelona-Lloret de Mar, Spain, 11-15 September, 2006
  • [2] J. Dobrovska: Chemical heterogeneity of metal alloys (Chemicka heterogenita kovovych slitin). Montanex, Ostrava – Marianske hory, 2005. ISBN 80-7225-182-1.
  • [3] L.E. Ritman: Micro-computed tomography—current status and developments. Annu. Rev. Biomed. Eng., 6(2004), 185.
  • [4] S.C. Lee, et al.: A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging. Phys. Med. Biol., 48(2003), 4173.
  • [5] E. Ratajczyk: Tomografy przemysłowe CT – rodzaje, parametry, zastosowania, testy dokładności, PAK, 60(2014), 713 (in Polish)
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2020).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-716572d9-82db-424d-9046-15b41a9fbd33
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.