PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Application of an aptamer and a reagent based on gold nanoparticles for detection of Escherichia coli

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Plates functionalized with an Escherichia coll binding aptamer and a reagent based on gold nanoparticles were used for the detection of bacterial cells. Bacteria suspended in samples were caught by specific aptamers immobilized on a plastic plate whereas the gold nanoparticle reagent is an indicator reagent for visualization of the test result. Changes in colour of the gold nanoparticle reagent caused by gold nanoparticle agglomeration were observed with the naked eye. The test was designed for the detection of Escherichia coli in water suspensions.
Rocznik
Strony
125--133
Opis fizyczny
Bibliogr. 11 poz., tab., rys.
Twórcy
autor
  • Department of Environmental Engineering, Wroclaw University of Technology, Wroclaw, Poland
  • Central Laboratory of Medical Biology, Poznan University of Medical Sciences, Poznan, Poland
autor
  • Department of Cell Biology, Poznan University of Medical Sciences, Poznan, Poland
  • Department of Environmental Engineering, Wroclaw University of Technology, Wroclaw, Poland
autor
  • Department of Environmental Engineering, Wroclaw University of Technology, Wroclaw, Poland
Bibliografia
  • [1] RADKE S., ALOCILJA E.C., A High Density Microelectrode Array Biosensor for Detection of E. coli O157:H7, Biosens. Bioelectron., 2005, 20 (8), 1662.
  • [2] CROXEN M.A., FINLAY B.B., Molecular mechanisms of Escherichia coli pathogenicity, Nature Rev. Micr., 2010, 8, 26.
  • [3] BERKENPAS E., MILLARD P., PEREIRA DA CUNHA M., Detection of Escherichia coli O157:H7 with langasite pure shear horizontal surface acoustic wave sensors, Biosens. Bioelectron., 2006, 21 (12), 2255.
  • [4] IVNITSKI D., ABDEL-HAMID I., ATANASOV P., WILKINS E., Biosensors for detection of pathogenic bacteria, Biosens. Bioelectron., 1999, 14, 599.
  • [5] MATSUOKA Y., SHIMIZU K., Importance of understanding the main metabolic regulation in response to the specific pathway mutation for metabolic engineering of Escherichia coli, Comput. Struct. Biotechnol. J., 2012, 3 (4), e201210018.
  • [6] KUHN K.G., FALKENHORST G., CEPER T., DALBY T., ETHELBERGS., MØLBAK K., KROGFELT K.A., Detection of antibodies to Campylobacter in humans using enzyme-linked immunosorbent assays: a review of the literature, Diagn. Micr. Infec. Dis., 2012, 74 (2), 113.
  • [7] ELLINGTON A.D., SZOSTAK J., In vitro selection of RNA molecules that bind specific ligands, Nature, 1990, 346, 818.
  • [8] NI X., CASTANARES M., MUKHERJEE A., LUPOLD S.E., Nucleic acid aptamers: clinical applications and promising new horizons, Curr. Med. Chem., 2011, 18 (27), 4206.
  • [9] JAYASENA S.D., Aptamers: An emerging class of molecules that rival antibodies in diagnostics. Clin. Chem., 1999, 45, 1628.
  • [10] HESSELBERTH J., ROBERTSON M.P., JHAVERI S., ELLINGTON A.D., In vitro selection of nucleic acids for diagnostic applications, Rev. Mol. Biotechnol., 2000, 74, 15.
  • [11] TURKEVICH, J., STEVENSON P.C.; HILLIER J., Nucleation and growth process in the synthesis of colloidal gold, Discuss. Faraday Soc., 1951, 11, 55.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-7113bc18-8d3a-4dca-b547-14cec4ce1ef4
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.