The aim of the study was to determine the biological degradability of pollutants in textile wastewater exposed to the action of various oxidants used either separately or in different combinations. The oxidizing agents were ozone, hydrogen peroxide and UV radiation. Researches were carried out using textile wastewater of different concentrations and compositions, including concentrated washing and dye baths, general averaged process wastewater and washing wastewater. It was found that oxidation processes appeared to be the most efficient methods for degradation of organic compounds present in wastewater. This was confirmed by decreasing COD values. However, in the case of BOD it was not so obvious. On the one hand, we could observe a decrease in its value, which was evidence of the decomposition of biodegradable organic compounds exposed to oxidation processes, but on the other, in many cases an increase in BOD was reported, which provided evidence of the degradation of organic compounds that were difficult to degrade biologically and of formation of more biodegradable compounds. It follows from the researches that ozone is the oxidizing agent which ensures the greatest increase in wastewater biodegradability. Special attention should be given to the selection of its proper doses.
PL
Celem badań było określenie podatności na rozkład biologiczny zanieczyszczeń obecnych w ściekach włókienniczych poddanych działaniu szerokiej gamy czynników utleniających stosowanych pojedynczo oraz w rozmaitych kombinacjach. Jako czynniki utleniające stosowano ozon, nadtlenek wodoru i promieniowanie UV. Badania prowadzono na ściekach włókienniczych o zróżnicowanym stężeniu i składzie obejmujących stężone kąpiele pralnicze i barwiarskie, ogólne uśrednione ścieki poprodukcyjne oraz ścieki z operacji płukania. Stwierdzono, że procesy utleniania są efektywnymi metodami doprowadzającymi do rozkładu cząsteczek związków organicznych obecnych w ściekach. Świadczą o tym obniżające się wartości ChZT. W przypadku wskaźnika BZT sytuacja nie jest już tak jednoznaczna. Z jednej strony obserwuje się spadek jego wartości świadczący o zachodzącym pod wpływem procesów utleniania rozkładzie związków organicznych podatnych na biodegradację. Z drugiej zaś strony, w wielu przypadkach obserwuje się wzrost BZT świadczący o zachodzącym rozkładzie trudno rozkładalnych biologicznie związków organicznych i tworzeniu się związków bardziej podatnych na biodegradację. Z badań wynika, że czynnikiem utleniającym dzięki któremu można uzyskać najbardziej znaczący wzrost podatności ścieków na rozkład biologiczny jest ozon. Należy jednak zwrócić szczególną uwagę na dobór właściwej jego dawki.
Rocznik
Strony
99--105
Opis fizyczny
Bibliogr. 22 poz., rys., tab.
Twórcy
autor
  • Textile Research Institute, Łódź, Poland
autor
  • Institut of Applied Radiation Chemistry, Technical University of Lodz, Łódź, Poland
Bibliografia
  • 1. Beltran F. J., Gonzales J., Industrial wastewater advanced oxidation. Part 1. UV radiation in presence and absence of hydrogen peroxide, Water Research, 31, 2405-2414, 1997.
  • 2. Beltran F. J., Encinar L., Gonzales J., Industrial wastewater advanced oxidation. Part 2. Ozone combined with hydrogen peroxide or UV radiation, Water Research, 31, 2415-2428, 1997.
  • 3. Kos L., Perkowski J., Ledakowicz S., Application of ozone, hydrogen peroxide and UV irradiation in textile wastewater treatment, AATCC Review, 4 (1), 30-34, 2004.
  • 4. Rice R.G., Applications of ozone for industrial wastewater treatment – a review, Ozone Science & Engineering, 19(5), 477, 1997.
  • 5. Getoff N., Radiation-induced degradation of water pollutants – state of the art, Radiation Physical Chemistry, 47 (4), 581-593, 1996.
  • 6. Getoff N., Advancements of radiationinduced degradation of pollutants in drinking and wastewater, International Journal Applied Radiation and Isotopes, 40, 585, 1998.
  • 7. Andreozzi R., Caprio V., Isola A., Marotta R., Advanced Oxidation Processes (AOP) for water purification and recovery, Catalysis Today, 53, 51-59, 1999.
  • 8. Malato S., Blanco J., Vidal A., Richter C., Photolysis with solar energy at a pilot plant scale: an overview, Appl. Cat. B. Ener., 37, 1-15, 2002.
  • 9. Fasnacht M.P., Blough N.V., Aqueous photodegradation of polycyclic aromatic hydrocarbons, Environ. Sci. Technol., 36, 4361-4369, 2002.
  • 10. Goi A., Trapido M., Hydrogen peroxide, Fenton reagent and photo-Fenton for the degradation of nitrophenols: a comparative study, Chemosphere, 46, 913-922, 2002.
  • 11. Perkowski J., Kos L., Żyłła R., Ledakowicz S., A kinetic model of decoloration of water solutions of anthraquinone dye initiated by generality hydroxyl radicals, Fibres & Textiles in Eastern Europe, 54 (6), 59-64, 2005.
  • 12. Bulska A., Perkowski J., Kos L., The application of ozone in the decomposition of aqueous solution of nonionic surfactants, Ozone Science & Engineering, 26 (2), 217-226, 2004.
  • 13. Perkowski J., Mayer J., Kos L., Reactions of non-ionic surfactants, Triton X-n type, with OH radicals. A review, Fibres & Textiles in Eastern Europe, 50 (2), 81-85, 2005.
  • 14. Perkowski J., Kos L., Decoloration of model dye house wastewater with advanced oxidation processes, Fibres & Textiles in Eastern Europe, 41 (2), 88-94, 2003.
  • 15. Perkowski J., Kos L., Ledakowicz S., Application of ozone in textile wastewater treatment, Ozone Science & Engineering, 18 (1), 73-85, 1996.
  • 16. Kos L., Perkowski J., Decoloration of real textile wastewater with advances oxidation processes, Fibres & Textiles in Eastern Europe, 43 (4), 81-85, 2003.
  • 17. Perkowski, J., Kos, L., Ledakowicz, S., Advanced oxidation of textile wastewaters, Ozone Science & Engineering, 22, 535-550, 2000.
  • 18. Perkowski J., Jóźwiak W., Kos L., Stajszczyk P., Application of Fenton’s reagent in detergent separation in highly concentrated water solutions, Fibres & Textiles in Eastern Europe, 59(5), 114-119, 2006.
  • 19. Perkowski, J., Kos L., Gamma irradiation combined with ozonization as a method of decomposition of impurities in textile wastes, Environ. Protec. Eng., 18, 5-17, 1992.
  • 20. Kos L., Perkowski J., Bzdon S., Application of photocatalytic oxidation in the presence of TiO2 in small sewage treatment plants, Separation Science and Technology, 42, 1553-1563, 2007.
  • 21. Beltran F.J., Garcia-Araya J.F., Alvarez P., Impact of chemical oxidation on biological treatment of a primary municipal wastewater, Ozone Science & Engineering, 19, 513, 1997.
  • 22. Scott J.P., Ollis D.F., Integration of chemical and biological oxidation processes for water treatment: review and recommendations, Environ. Progress, 10, 88, 1995.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-6d5006ec-05b4-4ca6-b4c5-d3cc81dab7c7
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.