PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The determination of measuring transformer windings impedance by using an three stage measuring method

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
A developed three stage method for determination the windings impedance of measuring transformer are shown in this paper. During the measurement process, there is no need to use the standard voltage divider instead, a voltage divider having the constant, unknown error is used. This ratio error is eliminated during measuring procedure. In this paper, the obtained measurement results of the winding impedance and uncertainty budged are presented.
Wydawca
Rocznik
Strony
268--270
Opis fizyczny
Bibliogr. 7 poz., rys., wykr., tab., wzory
Twórcy
autor
  • Silesian University of Technology, Department of Measurement Science, Electronics and Control 10 Akademicka St., 44-100 Gliwice
  • Silesian University of Technology, Department of Measurement Science, Electronics and Control 10 Akademicka St., 44-100 Gliwice
autor
  • Silesian University of Technology, Department of Measurement Science, Electronics and Control 10 Akademicka St., 44-100 Gliwice
autor
  • Silesian University of Technology, Department of Measurement Science, Electronics and Control 10 Akademicka St., 44-100 Gliwice
Bibliografia
  • [1] Skubis T., Piaskowy A.: Calibration and Leakage Impedance Measurements of a Standard 1:2 Ratio Autotransformer Inductive Voltage Divider, IEEE Transactions on Instrumentation and Measurement Vol.: 64 Issue: 2, s. 494-501, 2015.
  • [2] Kibble B. P., Rayner G. H.: Coaxial AC Bridges. Adam Hilger Ltd, Bristol, 1984.
  • [3] Skubis, T., Met, A.: A mathematical model of the admittance between tapped windings and their shield for ratio instruments. IEEE Transactions on Instrumentation and Measurement, vol. 38, Issue: 3, s. 764-768, 1989.
  • [4] Hurley W., Wilcox D.: Calculation of Leakage Inductance in Transformer Windings, IEEE Transaction on Power Electronics, vol. 9, no. 1, January 1994.
  • [5] Jinbo Zhao, Hao Feng, Tao Cai, Shanxu Duan: The complex ratio transformer model and its application in Magnetic resonant WPT, ITEC Asia-Pacific, IEEE Conference and Expo, Aug. 31 2014-Sept. 3 2014.
  • [6] Piaskowy A., Skórkowski A.: Relation between ratio error and leakage impedance, PPM 2016 s. 56-59.
  • [7] Skubis T., Skórkowski A., Piaskowy A., Pilśniak A.: Differential measurement method of windings impedance of measuring transformers, PPM 2015 s. 41-44.
Uwagi
PL
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-6c6a13d2-9356-426d-9401-6bbc056df67d
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.