PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Air pollution in landfill of wastes other than hazardous or inert

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Zanieczyszczenia powietrza na składowiskach odpadów innych niż niebezpieczne i obojętne
Języki publikacji
EN
Abstrakty
EN
Microbiological and chemical analysis of air was carried out on the area of landfill of wastes other than inert or hazardous. The landfill covers 20 ha and 40 000 Mg of wastes is deposited annually. Municipal waste is not segregated at the landfill. The research was conducted in April, May and November 2012. Number of the psychrophilic and mesophilic bacteria and fungi was estimated by a culture-based method. Quantitative determination of sulfur compounds and meteorological and olfactrometric examinations were also carried out. Chemical analysis was conducted with a Photovac Voyager portable gas chromatograph. Air samples were collected at 5 points. The largest group of microbes were psychrophilic bacteria, especially in summer. The highest concentration of hydrogen sulfide and other odorants was found at leachate tank and landfill body. According to the Polish Standard for the assessment of atmospheric air pollution the air in the area of the landfill is classified as not contaminated and sporadically moderately contaminated. In spring and summer the number of microscopic fungi was increased also in control samples.
PL
Przeprowadzono badania nad zanieczyszczeniem powietrza na terenie składowiska odpadów innych niż obojętne i niebezpieczne. Wybrany obiekt został otwarty w 1997; zajmuje 20 ha i rocznie przyjmuje 40 000 Mg odpadów komunalnych, które nie podlegają segregowaniu na składowisku. Zakres badań mikrobiologicznych obejmował analizę ilościową bakterii mezofilnych, psychrofilnych oraz grzybów mikroskopowych. Do poboru próbek powietrza zastosowano metodę zderzeniową. Analizy chemiczne polegały na oszacowaniu stężenia siarkowodoru oraz merkaptanu etylowego i metylowego za pomocą przenośnego chromatografu Photovac Voager. Określano ponadto takie parametry jak prędkość i kierunek wiatru oraz intensywność zapachu. Pobór próbek przeprowadzono w pięciu punktach. Wykazano emisję mikroorganizmów oraz siarkowodoru i odorów z terenu składowiska. Najliczniejszebyły bakterie psychrofilne, zwłaszcza w porze letniej. Wysoką liczbę bakterii mezofilnych i grzybów mikroskopowych stwierdzono na bryle czynnego składowiska. Najwyższe stężenie siarkowodoru i odorów wykryto w sąsiedztwie zbiornika na odcieki oraz na składowisku. Na podstawie polskiej normy dotyczącej jakości powietrza atmosferycznego należy określić powietrze na terenie składowiska jako nie zanieczyszczone (liczba grzybów) oraz średnio zanieczyszczone i nie zanieczyszczone (liczba bakterii psychrofilnych). Wiosną i latem zaobserwowano podwyższoną liczbę grzybów mikroskopowych również w próbkach kontrolnych.
Rocznik
Strony
41--46
Opis fizyczny
Bibliogr. 22 poz., tab.
Twórcy
  • Politechnika Warszawska, Poland Wydział Inżynierii Środowiska
  • Politechnika Warszawska, Poland Wydział Inżynierii Środowiska
Bibliografia
  • [1] Barabasz, W. & Albińska, D. (2005). Emission and propagation of microorganisms around municipal landfills, Inżynieria Ekologiczna, 11, pp. 119-121. (in Polish)
  • [2] Barabasz, W., Barabasz, J., Albińska, D. & Smyk, B. (2005). Community objects as a source of bioaerosols and microorganisms harmful to health, Gospodarka odpadami komunalnymi, 11, pp. 223-236. (in Polish)
  • [3] Białowiec, A., Bernat, K., Wojnowska-Baryła, I. & Agopsowicz, M. (2008). The effect of mechanical pretreatment of municipal solid waste on its potential in gas production, Archives of Environmental Protection, 34, 3, pp. 115-124.
  • [4] Buczyńska, A., Cyprowski, M. & Szadkowska-Stańczyk, I. (2006). Biological agents that are harmful to health, present in the air at the landfills, Medycyna Pracy, 57, 6, pp. 531-535. (in Polish)
  • [5] Gołofit-Szymczak, M. & Skowron, J. (2005). Microbiological hazards in the office space, Bezpieczeństwo pracy, 3, pp. 29-31. (in Polish)
  • [6] Kalisz, L., Sałbut, J. & Kaźmierczuk, M. (1995). Assessment of the impact of municipal facilities on microbial air quality and the spread of odors, Ochrona Środowiska i Zasobów Naturalnych, 9, pp. 125-143. (in Polish)
  • [7] Kaarakainen, P., Meklin, T., Rintala, H., Hyvarinen, A., Karkkainen, P., Vepsalainen, A., Hirvonen, M.R. & Nevalainen, A. (2008). Seasonal variation in airborne microbial concentrations and diversity at landfill, urban and rural sites, Clean, 36, 7, pp. 556-563.
  • [8] Kostryko, K. & Wargocki, P. (2012). Measurements of odors and noticeable indoor air quality, Instytut Techniki Budowlanej, Warszawa 2012 . (in Polish)
  • [9] Kośmider, J., Mazur-Chrzanowska, B. & Wyszyński, B. (2002). Odors, Wydawnictwo Naukowe PWN, Warszawa 2002. (in Polish)
  • [10] Kulig, A. (2004). Methods of measuring and calculating the environmental impact assessment of municipal objects, Oficyna Wydawnicza Politechniki Warszawskiej, Warszawa 2004. (in Polish)
  • [11] Małecka-Adamowicz, M., Kaczanowska, J. & Donderski, W. (2007). The impact of a landfill site in Żółwin- -Wypaleniska on the microbiological quality of the air, Polish Journal of Environmental Studies, 16 (1), pp. 101-107.
  • [12] Michałkiewicz, M. & Piskorek, J. (2008) Microbiological air pollution in municipal solid waste landfills, Rynek Instalacyjny, 11, pp. 95-100. (in Polish)
  • [13] Pawłowska, M., Czerwiński, J. & Stępniewski, W. (2008). Variability of the non-methane volatile organic compounds (NMVOC) composition in biogas from sorted and unsorted landfill material, Archives of Environmental Protection, 34, 3, pp. 287-298.
  • [14] Polish Norm (PN-89/Z-04111/02). Air purity protection. Microbiological testing. Determination of the number of bacteria in the atmosphere (immission) by the aspiration and sedimentation sampling method. (in Polish)
  • [15] Polish Norm (PN-89/Z-04111/03). Air purity protection. Mycological testing. Determination of the number of bacteria in the atmosphere (immission) by the aspiration and sedimentation sampling method. (in Polish)
  • [16] Siuta, J. (2005). National environmental policy, Inżynieria ekologiczna, 11, pp. 19-34. (in Polish)
  • [17] Skowron, J. & Gołofit-Szymczak, M. (2004) Microbiological contamination of the air in the work environment - sources, types and determination, Bromatologia i Chemia Toksykologiczna, 1, pp. 91-98. (in Polish)
  • [18] Szyłak-Szydłowski, M. & Grabińska-Łoniewska, A. (2009). Formation of the activated sludge biocenosis during landfill leachate pre-treatment in SBR, Archives of Environmental Protection, 35, 2, pp. 53-66.
  • [19] Szyłak-Szydłowski, M. & Grabińska-Łoniewska, A. (2010). The main microbiological contamination of landfill leachate, Gaz, Woda i Technika Sanitarna, 9, pp. 15-17. (in Polish)
  • [20] Wójcik, W. (2010) Landfill leachate treatment using constructed wetland with short detention time, Archives of Environmental Protection, 36, 3, pp. 51-58.
  • [21] Zaremba, M.L. & Borowski, J. (2001). Medical Microbiology, Wydawnictwo Lekarskie PZWL, Wyd. III, Warszawa 2001. (in Polish)
  • [22] Zarra, T., Belgiorno, V. & Naddeo, V. (2013). Odour Impact Assessment Handbook, John Wiley & Sons, Ltd., 2013.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-6b7be948-a1a7-4da7-a187-7e7a7d81acdb
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.