Probabilistic methods in the reliability assessment of power units

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Metody probabilistyczne w ocenie niezawodności bloków energetycznych
Języki publikacji
EN
Abstrakty
EN
The paper presents results of reliability analysis made for a lignite-fired 370 MW rated power units installed in the Bełchatów Power Station. The concept of a standardized power unit and the method of a histogram with a set number of observations in each class were applied. The study includes analysis of probability distributions of operation times and repair times for the main power unit components. Empirical probability distribution functions have been identified and their parameters estimated in the study. The final forecast includes an estimation of such reliability measures like expected operation time, expected failure rate, average repair time and expected annual failure duration.
PL
W artykule dokonano oceny niezawodności pracy krajowych bloków 370 MW opalanych węglem brunatnym, zainstalowanych w Elektrowni Bełchatów. W oparciu o koncepcję bloku reprezentatywnego i metodę histogramu o założonej liczbie realizacji w klasach wyznaczono rozkłady prawdopodobieństwa występowania czasów pracy i czasów awarii dla głównych urządzeń bloku oraz ich najbardziej zawodnych elementów. Następnie na podstawie estymacji parametrów uzyskanych w ten sposób rozkładów empirycznych określono dla tych elementów wartości oczekiwane ich podstawowych wskaźników niezawodnościowych: intensywności awarii, średniego czasu wyłączenia, łącznego czasu wyłączeń w ciągu roku i czasu pracy bezawaryjnej.
Twórcy
autor
  • Lodz University of Technology. Institute of Electrical Power Engineering. Łódź
autor
  • Lodz University of Technology. Institute of Electrical Power Engineering. Łódź
Bibliografia
  • [1] Allan R.N., Billinton R.: Power system reliability and its assessment. Power Engineering J. July 1992, volume 6, issue 4, 191-196.
  • [2] Zadrzyński E.: Reliability. Informatics, control and management in power systems. PWN, Warsaw 1979 (in Polish).
  • [3] Oziemski A., Sikora R.: Modeling of reliability of 370 MW units installed in BOT Bełchatów Power Station. Wiadomości Elektrotechniczne 12(2006), 34–38 (in Polish).
  • [4] Oziemski A., Sikora R.: Modeling of reliability of 370 MW units installed in BOT Bełchatów Power Station. In: Proc. XII Conference ZkwE’07 “Computer Applications in Electrical Engineering”, Poznań, April 2007, 207–208 (in Polish).
  • [5] Buchta J., Oziemski A., Pawlik M.: Estimation of reliability measures of 370 MW lignite fueled power units operating in Poland. In: Proc. 6th International Scientific and Technical Conference “Efficiency and Power Quality of Electrical Supply of Industrial Enterprises”. Mariupol (Ukraine), May 2008, 295–298.
  • [6] Buchta J., Oziemski A.: Reliability modeling of large coal-fired power units. In: Proc. 8th International Conference “Control of Power Systems ’08”. Strbske Pleso (Slovakia), June 2008, CD proceeedings, 66.
  • [7] Oziemski A., Pawlik M.: Estimation of reliability measures for lignite fired 370 MW power units. Kwartalnik Akademii Górniczo-Hutniczej w Krakowie, Górnictwo i Geoinżynieria 2(2009), 363–372 (in Polish).
  • [8] Barlow R.E., Proschan F.: Mathematical Theory of Reliability. Wiley, New York 1965.
  • [9] Lehmann E.L.: Testing Statistical Hypotheses. PWN, Warsaw 1968 (in Polish).
  • [10] Kececioglu D.: Reliability Engineering Handbook. DEStech Publ., 2002.
  • [11] Paska J., Wójcik P., Bargiel J., Goc W., Sowa P.: Data for electric power system calculations. In: Proc. 8th International Conference on Electrical Power Quality and Utilisation, September 2005, 477–482.
  • [12] Lesiński S.: of investigation results by histogram method. Zeszyty Naukowe Politechniki Łódzkiej ser. Elektryka 63(1978), 95–105 (in Polish).
  • [13] Pawlik M., Strzelczyk F.: Power Stations. WNT, Warsaw 2009 (in Polish).