Ocena stanu technicznego zapalników min o działaniu mechanicznym
Języki publikacji
Abstrakty
Contemporary armed conflicts reveal that the use of effective mine barriers has a significant impact on the course of hostilities. Therefore, the Polish Armed Forces selected reliable and effective explosive ordnance as a priority, both newly-acquired material and those currently in operation. For this reason, among others, strict supervision over the technical condition of mines is exercised, in particular during their long-term storage. The reasons behind the increased mine unreliability may include physical and chemical changes in the construction materials used (corrosion, deformations, loss of strength properties), deterioration of the physicochemical properties of the main charge, booster and primer-detonator, inadequate technical condition of the safety components, or the failure of mine fuse mechanisms. In order to assess the mine's operational reliability, each mine fuse subassembly is examined and then a check of the entire assembled mine is performed. This requires proper planning of the full test cycle and the use of inspected and calibrated measuring devices and test stands enabling the precise adjustment of mechanical and climatic stress parameters.
Współczesne konflikty zbrojne pokazują, iż stosowanie skutecznych zapór minowych ma znaczący wpływ na przebieg działań wojennych. Z uwagi na ten fakt, w Siłach Zbrojnych RP priorytetem jest posiadanie niezawodnych i efektywnych środków minersko-zaporowych, zarówno nowo pozyskanych jak i tych będących w eksploatacji. Z tego też powodu prowadzi się między innymi szczegółowy nadzór nad stanem technicznym min, zwłaszcza w okresie ich długotrwałego przechowywania. Przyczynami zwiększonej zawodności działania min mogą być: fizykochemiczne zmiany w materiałach konstrukcyjnych (korozja, deformacje, utrata właściwości wytrzymałościowych) pogorszenie się właściwości fizykochemicznych zasadniczego materiału wybuchowego miny, detonatora pośredniego i spłonki pobudzającej, zły stan techniczny podzespołów zabezpieczeń lub niesprawność mechanizmów zapalnika miny. W celu oceny niezawodności działania miny wykonuje się sprawdzenie niezależnie każdego podzespołu zapalnika miny, a następnie kompleksowe sprawdzenie jej stanu technicznego. Wymaga to prawidłowego zaplanowania pełnego cyklu badań oraz stosowanie nadzorowanego wyposażenia pomiarowego i stanowisk badawczych umożliwiających, w czasie badań, precyzyjną nastawę zadawanych parametrów narażeń mechanicznych i klimatycznych.
Czasopismo
Rocznik
Tom
Strony
art. no. e2021025
Opis fizyczny
Bibliogr. 15 poz., fot., wykr.
Twórcy
autor
- Military Institute of Engineer Technology
autor
- Military Institute of Engineer Technology
autor
- Military Institute of Engineer Technology
autor
- Military Institute of Engineer Technology
autor
- Military Institute of Engineer Technology
autor
- Military Institute of Engineer Technology
Bibliografia
- 1. Center for International Stabilization and Recovery, (2009). Scoping Study of the Effects of Aging on Landmines. Global CWD Repository. 21. https://commons.lib.jmu.edu/cisr-globalcwd/21 (date of access: 15/09/2021).
- 2. Chant, I., Lee, D., Ireland, D. (2005). DSTO Landmine Detection Test Targets. Edinburgh South Australia: DSTO Systems Sciences Laboratory.
- 3. Dokumentacja techniczna na minę kolejową PMK-1, arch. WITI nr 14/09/9.
- 4. Fokin, J.G. (1973). Niezawodność eksploatacyjna urządzeń technicznych. Warszawa: Wydawnictwo Ministerstwa Obrony Narodowej.
- 5. Fonrobert, P., Stępień, L., Terenowski, H. (2011). Podejmowanie decyzji o dalszej eksploatacji środków bojowych na podstawie informacji o ich eksploatacji. Problemy Techniki Uzbrojenia, R. 40, z. 120(4), 93–101. Zielonka: Wojskowy Instytut Techniczny Uzbrojenia.
- 6. Kubecki, A., Śliwiński, J., Lubach, I. (2019). Metodyka badań min przeciwpancernych TM-62M z zapalnikami MWCz-62 w procesie eksploatacji. Wrocław: Military Institute of Engineer Technology.
- 7. Mina przeciwdesantowa denna PDM-1M, Warunki Techniczne WT-0199/Inż.
- 8. Mina przeciwdesantowa rzeczna MPR z zapalnikami mechanicznego działania, Warunki Techniczne WT-0198/Inż.
- 9. Mina przeciwpancerna MPP-61 z zapalnikiem MUND-62, Warunki Techniczne WT-226/Inż.
- 10. Mina przeciwpancerna PT Mi-Ba-III z zapalnikiem Ro-2, Warunki Techniczne WT-0374/Inż.
- 11. Sztab Generalny Wojska Polskiego, Szefostwo Wojsk Inżynieryjnych, Inż. 414/78 (1978). Środki minowania i rozminowania: opis i użytkowanie. Warszawa: Ministerstwo Obrony Narodowej.
- 12. Sztab Generalny Wojska Polskiego, Szefostwo Wojsk Inżynieryjnych, Inż. 572/94 (1994). Prace minerskie i niszczenia. Warszawa: Minosterstwo Obrony Narodowej.
- 13. Urządzenie do badania min z zapalnikiem o działaniu naciskowym, application for utility model, no. W.129234.
- 14. Urządzenie do badania zapalników naciskowych, utility model no. RWU.070345.
- 15. Warunki Techniczne na odbiór zapalnika MWCz-62, Nr ChF4.029.047 TU/S.