Tytuł artykułu
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
Purpose: To compare the impact of different bridge constructions and different loads on stress distribution in bridges. Design/methodology/approach: The study was conducted on 96 computer models of both premolars and molars that simulated a missing second premolar restored with a bridge supported on crown inlays or onlays. Simulations were made of a bridge constructed from four different materials: Au alloy, Cr/Ni alloy as well as two kinds of glass fibre-reinforced composites: Targis Vectris and FibreKor /Sculpture. The study was conducted using the finite element method (FEM). The results were analysed with PQStat statistical software version 1.6. Findings: In none of the analysed cases did stresses appear capable of damaging the bridge construction. Reduced stresses were lower in glass fibre reinforced composite materials than in metal alloys. Practical implications: The force application point has a decisive influence on stress distribution in the hard dental tissue and in bridges. The highest stress values occurred at the loading of the pontic tooth. Originality/value: The force application point has a decisive influence on stress distribution in the hard dental tissue and in bridges. The highest stress values occurred at the loading of the pontic tooth.
Wydawca
Rocznik
Tom
Strony
71--78
Opis fizyczny
Bibliogr. 44 poz.
Twórcy
autor
- Department of Prosthodontics, Medical University of Lodz, ul. Pomorska 251, 92-213 Łódź, Poland
autor
- Department of Strength of Materials of the Technical University of Lodz, ul. Stefanowski 1/15, 90-924 Łódź, Poland
autor
- Institute of Material Science and Engineering, Lodz University of Technology, ul. Stefanowski 1/15, 90-924 Łódź, Poland
autor
- Department of Dental Techniques, Medical University of Lodz, ul. Pomorska 251, 92-231 Łódź, Poland
- Institute of Material Science and Engineering, Lodz University of Technology, ul. Stefanowski 1/15, 90-924 Łódź, Poland
Bibliografia
- [1] A.L. Rochette, Attachment of a splint to enamel of lower anterior teeth, Journal of Prosthetic Dentistry 30 (1973) 418-423.
- [2] M.R. Dimashjieh, A.R. Al-Shammery, Long-term survival of sleeve-designed fixed partial dentures: a clinical report, Journal of Prosthetic Dentistry 84 (2000) 591-593.
- [3] A.A. Saad, N. Claffey, D. Byrne, D. Hussey, Effect of groove placement on retention/resistance of maxillary anterior resin-bonded retainers, Journal of Prosthetic Dentistry 74 (1995) 133-139.
- [4] T.A. Imbery, E.G. Eshelman, Resin-bonded fixed partial den- tures: a review of three decades of progress, The Journal of the American Dental Association 127 (1996) 751-760.
- [5] R. Stockholm, F. Isidro, Resin-bonded inlay retainer pros- theses for posterior teeth. A 5-year clinical study, International Journal of Prosthodontics 9 (1996) 161-166.
- [6] T. Kerschbaum, B. Haastert, C.P. Marinello, Risk of de-bonding in three-unit resin-bonded fixed partial dentures, Journal of Prosthetic Dentistry 57 (1996) 248-253.
- [7] A. Mudassir, Y.E. Aboush, M. Hosein, T. Hosein, I. Padihar, Long- term clinical performance of resinbonded fixed partial dentures placed in a developing country, Journal of Prosthodontics 4 (1995) 233-236.
- [8] W.P. Saunders, Resin- bonded bridge work: a review, Journal of Dentistry 17 (1989) 255-265.
- [9] V.D. Williams, K.E. Thayer, G. Denehy, D.B. Boyer, Cast metal resin-bonded prostheses: a 10-year retrospective study, Journal of Prosthetic Dentistry 61 (1989) 436-441.
- [10] C.C. van Heumen, C.M. Kreulen, M.E. Bronkhorst, E. Lesaffre, N.H. Creugers, Fiber-reinforced dental composites in beam testing, Dental Materials 24 (2008) 1435-1443.
- [11] O. El-Mowafy, M.H.M. Rubo, Resin-bonded fixed partial dentures: a literature review with presentation of a novel approach. International Journal of Prosthodontics 13/6 (2000) 460-467.
- [12] K.A. Durey, P.J. Nixon, S. Robinson, M.F.W.Y. Chan, Resin bonded bridges: techniques for success, British Dental Journal 211/3 (2011) 113-118.
- [13] N.H. Creugers, A.F. Kayser, An analysis of multiple failures of resin-bonded bridges, Journal of Dentistry 20 (1992) 348-351.
- [14] G. Priest, An eleven-year revaluation of resin-bonded fixed partial dentures, The International Journal of Periodontics and Restorative Dentistry 15 (1995) 239-247.
- [15] M. Botelho, Resin-bonded prostheses: the current state of development, Quintessence International 30 (1999) 525-534.
- [16] J.F. Simon, R.G. Gartrell, A. Grogono, Improved retention of acid-etched fixed partial dentures: a longitudinal study, Journal of Prosthetic Dentistry 68 (1992) 611-615.
- [17] J.D. Duncan, G.W. Reeves, J.G. Fitchie, Adding retention features in the rebonding of cast metal resin-bonded prostheses, Journal of Prosthodontics 2 (1993) 67-69.
- [18] O. Hannson, B. Bergstrom, A longitudinal study of resin bonded prostheses. Journal of Prosthetic Dentistry 76 (1996) 132-139.
- [19] K.V. Pekka, S. Camilla, Resin-bonded, glass fiberreinforced composite fixed partial dentures: a clinical study, Journal of Prosthetic Dentistry 84 (2000) 413-418.
- [20] C.P. Marinello, T. Kerschbaum, B. Heinenberg, R. Hinz, S. Peters, P. Pfeiffer, P.D. Reppel, H. Schwickerath, Experiences with resin bonded bridges and splints-a retrospective study, Journal of Oral Rehabilitation 14 (1987) 251-260.
- [21] R.J. De Kanter, N.H. Creugers, C.W. Verzijden, M.A. van’t Hof, A five-year multi-practice clinical study on posterior resin- bonded bridges, Journal of Dental Research 77 (1998) 609-614.
- [22] T.N. Göhring, M. Roos, Inlay-fixed partial dentures adhesively retained and reinforced by glass fibres: clinical and scanning electron microscopy analysis after five year, European Journal of Oral Sciences 113/1 (2005) 60-69.
- [23] L. Shi, A.L. Fok, Structural optimization of the fibrereinforced composite substructure in a three-unit dental bridge, Dental Materials 25 (2009) 791-801.
- [24] D.L. Hussey, C. Pagni, G.J. Linden, Performance of 400 adhesive bridges fitted in a restorative dentistry department, Journal of Dentistry 19 (1991) 221-225.
- [25] J.B. Eshleman, P.C. Moon, R.F. Barne, Clinical evaluation of cast metal resin-bonded anterior fixed partial dentures, Journal of Prosthetic Dentistry 51 (1984) 761-764.
- [26] L. Yanover, W. Croft, F. Pulver, The acid-etched fixed prosthesis, The Journal of the American Dental Association 104 (1982) 325-328.
- [27] G.J. Re, D.A. Kaiser, W.F. Malone, F. Garcia-Godoy, Shear bond strengths and scanning electron microscope evaluation of three different retentive methods for resin-bonded retainers, Journal of Prosthetic Dentistry 59 (1988) 568-573.
- [28] B.E. Pjetursson, W.C. Tan, K. Tan, U. Brägger, M. Zwahlen, N.P. Lang, A systematic review of the survival and complication rates of resin-bonded bridges after an observation period of at least 5 year, Clinical Oral Implants Research 19/2 (2008) 131-141.
- [29] C.C. van Heumen, J.W. van Dijken, J. Tanner, R. Pikaar, L.V. Lassila, N.H. Creugers, P.K. Vallittu, C.M. Kreulen, Five-year survival of 3-unit fiberreinforced composite fixed partial dentures in the anterior area, Dental Materials 25/6 (2009) 820-827.
- [30] D. Yokoyama, A. Shinya, H. Gomi, P.K. Vallittu, Effects of mechanical properties of adhesive resin cements on stress distribution in fiber-reinforced composite adhesive fixed partial dentures, Dental Materials Journal 31/2 (2012) 189-196.
- [31] J.M. Powers, R. Sakaguchi, Craig’s restorative dental materials. 12th ed., St. Louis, Mosby, 2006.
- [32] M.H. Ho, et al., Three-dimensial finite element analysis of the effects of posts on stress distribution in dentine, Journal of Prosthetic Dentistry 72/4 (1994) 367-372.
- [33] P. Magne, N. Perakis, U.C. Belser, I. Krejci, Stress distribution of inlay-anchored adhesive fixed partial dentures: a finite element analysis of the influence of restorative materials and abutment preparation design, Journal of Prosthetic Dentistry 87/5 (2002) 516-528.
- [34] C. Gibbs, P. Mahan, H. Lundeen, K. Brehnan, E. Walsh, W. Holbrook, Occlusal forces during chewing and swallowing as measured by sound transmission, Journal of Prosthetic Dentistry 46/4 (1981) 443-449.
- [35] O.C. Zienkiewicz, R.L. Taylor, J.Z. Zhu, The finite element method, its basis and fundamentals 6th ed., Amsterdam, Elsevier-Butter-worth-Heinemann, 2005, 103-128.
- [36] M. Ash, S. Nelson, Wheeler’s dental anatomy, physiology and occlusion. 8th ed., Philadelphia, Saunders Co, 2003, 297-314.
- [37] R. De Groot, M. Peters, Y. De Haan, G. Dop, A. Plasschaert, Failure stress criteria for composite resin, Journal of Dental Research 66/12 (1987) 1748-1752.
- [38] D.T. Reily, A.H. Burstein, The mechanical properties of cortical bone, The Journal of Bone & Joint Surgery 56/5 (1974) 1001-1022.
- [39] J.Y. Rho, R.B. Ashman, C.H. Turner, Young’s modulus of trabecular and cortical bone material: ultrasonic and microtensile measurements, Journal of Biomechanics 26/2 (1993) 111-119.
- [40] L.M.H. Habets et al., Mandibular atrophy and metabolic bone loss, International Journal of Oral and Maxillofacial Surgery 16 (1987) 540-547.
- [41] C.A. Mitchell, J.G. Kennedy, A semi-empirical model for prediction of how post-retained crowns will fail under compressive loading, Journal of Dental Research 71/9 (1992) 1613-1618.
- [42] J.F. Orr, C.A. Mitchell, The evaluation of postretained crowns using a custom-designed fatigue machine, Journal of Oral Rehabilitation 23/3 (1996) 179-185.
- [43] C.L. Lin, C.H. Chang, C.S. Cheng, H.E. Lee, Threedimensional finite element meshing generation for maxillary second premolar, Computer Methods and Programs in Biomedicine 59 (1999) 187-195.
- [44] C.L. Lin, H.E. Lee, C.H. Wang, K.H. Chang. Interfacial stress analysis between posterior resinbonded bridge and abutments by finite element approach, Computer Methods and Programs in Biomedicine72 (2003) 55-64.
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017)
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-68f68ac9-6201-402f-8082-0abf04e9b27f