Method of estimating the exposure of the natural environment to 50 Hz electric and magnetic fields in power systems with distributed and centralized generations

Autorzy
Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The development of a distributed generation will influence the structure of the power transmission and distribution network. Distributed sources have lower power and therefore the lines of lower voltage are used. Therefore, the electric field intensity near such lines is lower. On the other hand magnetic field intensity may prove essential. The main aim of the paper is to present a method estimating the “ballast” of the natural environment at 50 Hz electric and magnetic fields in the power system, with distributed and centralized generation in real operating conditions.
Rocznik
Strony
295--304
Opis fizyczny
Bibliogr. 12 poz., fig., tab.
Twórcy
autor
  • West Pomeranian University of Technology, Szczecin Faculty of Electrical Engeneering Al. Piastów 17, 70-310, Szczecin, Poland
Bibliografia
  • [1] Krajewski W., Analysis of electric and magnetic fields around a lineman during live working, Electrical Review, 83(9): 57-59 (2007).
  • [2] Wróblewski Z., Habrych M., Electromagnetic field distribution under high voltage lines depending on geometrical systems of phase conductors on pillar, Electrical Review 81(6): 15-19 (2005).
  • [3] Krajewski W., Boundary and line elements in the analysis of selected EMC problems of low frequency, Poceedings of Electrotechnical Institute, Warszawa, LII, Zeszyt 224 (2005).
  • [4] Bednarek K., Nawrowski R., Tomczewski A., Analysis of electric field distribution in optimization of three-phase heavy-current busways operating in plane arrangement, Electrical Review 82(12): 49-52 (2005).
  • [5] Budnik K., Machczyński W., Contribution to studies on calculation of the magnetic field under power lines, European Transactions on Electrical Power 16: 345-364 (2006).
  • [6] Regulation issued by Minister of the Environment on 30th of October 2003 on permissible levels of electromagnetic fields in the environment and the ways of theirs restricting (in Polish), Polish Journal of Laws 192, pos. 1883 (2003)
  • [7] Groszko M., Polish regulation on maximum admissible intensities for electric and magnetic frequencies of 50 Hz and the European Union recommendations for electrical power engineering, Medycyna Pracy 54(2): 175-179 (2003).
  • [8] Power transmission lines and substations in human environment (in Polish), PSE-Operator, Warszawa 2009.
  • [9] Zeńczak M., 50 Hz electric and magnetic field under distributed and centralized generation(in Polish), Wiadomości Elektrotechniczne, LXXXII (12): 27-29 (2014).
  • [10] Grobicki J., Fermata M., Power conductors and cables (in Polish), WN-T (2010).
  • [11] Siwy E., Żmuda K., Intensification of the network using in the distribution, Electrical Review 85(3): 243-246 (2009).
  • [12] http://www.ptpiree.pl, accessed May 2015.