We present a project of a system of biological signal measurement for psychological profiling of soldiers. The system consists of specialized modules divided into measurement, communications, and powering blocks. The individual devices of the system communicate with one another thorough a dedicated protocol based on the CAN bus interface. The measurement system was designed as a portable, battery-powered device that could be attached to clothing. Apart from hardware, the system comprises a number of desktop and server applications. For data processing and storage, a number of dedicated applications were designed ranging from server applications to mobile user applications. In the article, we review mechanisms that employ genetic algorithms for a determination of the set of traits of an optimal psychological profile. Moreover, we describe ways of remote transmission of information to data bases with the use of the GPRS system. The presented system is designed as a specialized SOC integrated circuit.
Twórcy
  • Military Institute of Aviation Medicine, ul. Krasiskiego 54/56, 01-755 Warsaw, Poland
  • Military Institute of Aviation Medicine, ul. Krasiskiego 54/56, 01-755 Warsaw, Poland
  • Military Institute of Aviation Medicine, ul. Krasiskiego 54/56, 01-755 Warsaw, Poland
autor
  • Military University of Technology, ul. Gen. S. Kaliskiego 2, 00-908 Warsaw, Poland
Bibliografia
  • [1] Bosch Sensortec, “Data sheet Bmp180 Digital pressure sensor,” 2013.
  • [2] A. Łuczak and A. Tarnowski, “Badania psychologiczne kierowców,” CIOP-PIB, Warszawa, 2011.
  • [3] Medlab, “PEARL 200 Techncal manual,” 2014.
  • [4] Rigel, “UNI-SIM Vital Signs Simulator Technical data Sheet,” 2009.
  • [5] Rigol, “DG1000Z Series function/arbitrary waveform generator,” 2012.
  • [6] K. Różanowski, T. Sondej, J.Lewandowski, M. Luszczyk and Z. Szczepaniak, “Multisensor system for monitoring human psychophysiologic state in extreme conditions with the use of microwave sensor,” Proceedings of the 19th International Conference Mixed Design of Integrated Circuits and Systems, pp. 417-424, 2012.
  • [7] K. Różanowski, Ł. Dziuda and F. Skibniewski, „Wielokanałowy system rejestracji sygnałów fizjologicznych i rodowiskowych w warunkach realnego lotu „Ventus,” Polski Przegld Medycyny Lotniczej, 4 (12), 397-410, (*MNiSW – 4 pkt.), (**MNiSW – 4 pkt.), 2006.
  • [8] K. Różanowski, T. Sondej and T. Radomski, „Wielozadaniowy system monitorowania sygnałów fizjologicznych i rodowiskowych”, Elektronika konstrukcje, technologie, zastosowania, 48 (9), 85-89, (*MNiSW – 6 pkt.), (**MNiSW – 6 pkt.), 2007.
  • [9] K. Różanowski, T. Sondej and J. Lewandowski, "First Approach to a Design of an Autonomous Measurement System to Aid Determination of the Psychological Profile of Soldiers”.
  • [10] Sensirion, "Datasheet SHT21 Humidity and Temperature Sensor IC," 2014.
  • [11] STMicroeletronics, "STM32F405xx, STM32F407xx Datasheet,” 2013.
  • [12] SunTech, "Advantage A+ Operations manual," 2008.
  • [13] A. Tarnowski, ”Pamięć robocza i mechanizmy kontroli ruchów oka,” Warszawa, Wydawnictwo Instytutu Psychologii PAN, 2009.
  • [14] A. Tarnowski and K. Łapkiewicz, "Possibilities and limitations of automated psychological profiling," International Conference Mixed Design of Integrated Circuits and Systems, 2015, (submitted for publication).
  • [15] Texas Instruments, "Low-Power, 8-Channel, 24-Bit Analog Front-End for Biopotential Measurements," 2010.
  • [16] T. Vuorela, V.-P. Seppa, J. Vanhala and J. Hyttinen, “Design and Implementation of a Portable Long-Term Physiological Signal Recorder,” IEEE Transactions on Information Technology in Biomedicine, vol. 14, Issue 3, pp. 718-725, 2010.
  • [17] Xiao-Fei Teng, Yuan-Ting Zhang, C.C.Y. Poon and P. Bonato, “Wearable Medical Systems for p-Health,” IEEE Reviews in Biomedical Engineering, vol. 1, pp. 62-74, 2008.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-68488ed1-7aad-41ba-99a0-fa8805402296
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.