PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

IOT based smart cold chain temperatur monitoring and alert system for vaccination container

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Inteligentny system monitorowania temperatury w łańcuchu chłodniczym oparty na IOT i system ostrzegania o pojemniku na szczepienia
Języki publikacji
EN
Abstrakty
EN
A vaccination is one of primary precautionary source to prevent the severe effects of corona virus. The vaccination has to be maintained in the temperature range of 2OC to 8OC. The proposed system measures and monitors the temperature inside the vaccine container. A thermocouple device and smart controller encapsulated inside the container. The thermocouple senses the temperature in container. The smart WiFi enabled controller measure the temperature using electrical output of thermocouple. The measured temperature is passed to the cloud server and mobile view. The data and time wise maintenance of vaccine temperature, emergency indication, and current vaccine container temperature are displayed in the cloud. The system is useful on maintaining vaccine at prescribed temperature level and effectively protects the human life. The system achieved the accuracy of 99.5%.
PL
Szczepienie jest jednym z podstawowych środków ostrożności, aby zapobiec poważnym skutkom koronawirusa. Szczepienie należy prowadzić w zakresie temperatur od 2OC do 8OC. Proponowany system mierzy i monitoruje temperaturę wewnątrz pojemnika na szczepionkę. Termopara i inteligentny sterownik zamknięte w pojemniku. Termopara wyczuwa temperaturę w pojemniku. Inteligentny sterownik obsługujący WiFi mierzy temperaturę za pomocą wyjścia elektrycznego termopary. Zmierzona temperatura jest przekazywana do serwera w chmurze i widoku mobilnego. Dane i czasowe utrzymywanie temperatury szczepionki, wskazanie sytuacji awaryjnej i aktualna temperatura pojemnika na szczepionki są wyświetlane w chmurze. System jest przydatny w utrzymywaniu szczepionki w przepisanym poziomie temperatury i skutecznie chroni ludzkie życie. System osiągnął dokładność 99,5%.
Słowa kluczowe
Rocznik
Strony
206--208
Opis fizyczny
Bibliogr. 12 poz., rys., tab.
Twórcy
  • Department of ECE, Sona College of Technology, Salem, India
autor
  • Department of ECE, Sona College of Technology, Salem, India
  • Department of ECE, Knowledge Institute of Technology, Salem, India
  • Department of ECE, Karunya Institute of Technology and Sciences, Coimbatore, India
autor
  • Department of ECE, Karunya Institute of Technology and Sciences, Coimbatore, India
Bibliografia
  • [1] Yakum, M.N., Ateudjieu, J., Pélagie, F.R. et al. Factors associated with the exposure of vaccines to adverse temperature conditions: the case of North West region, Cameroon. BMC Res Notes 8, 277 (2015).
  • [2] Bajrovic, I., Schafer, S. C., Romanovicz, D. K., & Croyle, M. A. (2020). Novel technology for storage and distribution of live vaccines and other biological medicines at ambient temperature. Science Advances, 6(10), eaau4819.
  • [3] Hanson, C. M., George, A. M., Sawadogo, A., & Schreiber, B.(2017). Is freezing in the vaccine cold chain an ongoing issue? A literature review. Vaccine, 35(17), 2127–2133.
  • [4] Maglasang, P. L., Butalid, M. L., Pastoril, M. F., Pratama, A. N., & Tan, E. Y. (2018). A cross-sectional survey on cold chain management of vaccines in Cebu, Philippines. Pharmacy Practice, 16(2), 1167.
  • [5] Sow, C., Sanou, C., Medah, C., Schlumberger, M., Mireux, F., Ouédraogo, I., Ouédraogo, S., & Betsem, E. (2018). Challenges of cold chain quality for routine EPI in south-west Burkina-Faso: An assessment using automated temperature recording devices. Vaccine, 36(26), 3747–3755.
  • [6] Yamoah, Peter, Varsha Bangalee, and Frasia Oosthuizen. 2019. "Knowledge and Perceptions of Adverse Events Following Immunization among Healthcare Professionals in Africa: A Case Study from Ghana" Vaccines 7, no. 1: 28.
  • [7] Ateudjieu, J., Yakum, M., Goura, A.P. et al. EPI immunization coverage, timeliness and dropout rate among children in a West Cameroon health district: a cross sectional study. BMC Public Health 20, 228 (2020).
  • [8] Lutukai, M., Bunde, E. A., Hatch, B., Mohamed, Z., Yavari, S., Some, E., Chweya, A., Kania, C., Ross, J. C., Keddem, C., & Chandani, Y. (2019). Using Data to Keep Vaccines Cold in Kenya: Remote Temperature Monitoring With Data Review Teams for Vaccine Management. Global Health: Science and Practice, 7(4), 585–597.
  • [9] Ringo, S., Mugoyela, V., Kaale, E., & Sempombe, J. (2017). Cold Chain Medicines Storage Temperature Conformity by the World Health Organisation in Tanzania. Pharmacology & Pharmacy, 08(10), 325–338.
  • [10] Thiyaneswaran. B, Bhuvaneshwaran. V, Dharun. M.S, Gopu. K, Gowikan. T. (2020). Breathing Level Monitoring and Alerting by Using Embedded IOT, Journal of Green Engineering, 10(6), 2986 –2994.
  • [11] Das, M. K., Arora, N. K., Mathew, T., Vyas, B., Devi, S. K., & Yadav, A. (2020). Temperature integrity and exposure of vaccines to suboptimal temperatures in cold chain devices at different levels in three states of India. Tropical Diseases, Travel Medicine and Vaccines, 6(1).
  • [12] B. Thiyaneswaran, P. Elayaraja, P. Srinivasan, S. Kumarganesh, K. Anguraj, IoT based air quality measurement and alert system for steel, material and copper processing industries, Materials Today: Proceedings, 2021, ISSN 2214-7853
Uwagi
Opracowanie rekordu ze środków MEiN, umowa nr SONP/SP/546092/2022 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2022-2023).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-67bdfada-2a7f-46f6-8293-591388379f15
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.