Influence of Structural Parameters - the Shape of Graphite and Matrix on Change of Ultrasonic Wave Propagation Rate and Value of Attenuation in Graphitic Cast Irons

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Despite the tendency of the current industry, especially the automotive industry, it is to use modern, light and super-strong materials based on Al or HSLA steels, the application of classic materials such as cast iron still makes sense, especially concerning price and excellent castability. The article presents one of the possible ways of using the ultrasonic non-destructive method in quality control and simpli-fication of the identification of the type of cast iron concerning the change of parameters of ultrasound propagation in materials. The main criteria for assessing the quality and determining the type of graphite cast iron were considered to be the rate of propagation of ultrasound - cL and the value of attenuation , which vary depending on the shape of the graphite and matrix. Graphitic cast irons with different graphite shapes (lamellar, vermicular, and globular shapes) and a matrix with different ferrite/perlite ratios were used as experimental material. Along with the ultrasonic tests, a metallographic analysis was also performed to quantify the microstructure of cast irons.
Rocznik
Strony
23--27
Opis fizyczny
Bibliogr. 13 poz., rys., tab.
Twórcy
autor
  • Faculty of Mechanical Engineering, University of Žilina. Univerzitná 8215/1, 01026 Žilina, The Slovak Republic
autor
  • Faculty of Mechanical Engineering, University of Žilina. Univerzitná 8215/1, 01026 Žilina, The Slovak Republic
  • Faculty of Mechanical Engineering, University of Žilina. Univerzitná 8215/1, 01026 Žilina, The Slovak Republic
  • Faculty of Mechanical Engineering, University of Žilina. Univerzitná 8215/1, 01026 Žilina, The Slovak Republic
Bibliografia
  • 1. Collins, D.N., Alcheikh, W., 1995. Ultrasonic Non-destructive Evaluation of the Matrix Structure and the Graphite Shape in Cast Iron. J. of Materials Processing Technology,55, 85-90.10.1016/0924-0136(95)01789-5
  • 2. El-Hadad, S., Ibrahim, M., Mourad, M. et al., 2019. Ultrasonic Detection of Microstructure Features in Ti-Alloyed Ductile Iron. Trans Indian Inst Met, 72, 2349–2358.10.1007/s12666-019-01686-0
  • 3. Emerson, P.J., Simmons, W., 1976. Final Report on the Evaluation of the Graphite Form in Ferritic Ductile Iron by Ultrasonic and Sonic Testing, and the Effect of Graphite Form on Mechanical Properties. AFS Trans., 76-26, 109-128.
  • 4. Fuller, A.G., 1977. Evaluation of the Graphite Form in Pearlitic Ductile Iron by Ultrasonic and Sonic Testing and the Effect of Graphite Form on Mechanical Properties. AFS Trans.,77-102, 509-526.
  • 5. Fuller, A.G., Emerson, P.J., Sergeant, G.F., 1980. A Report on the Effect Upon Mechanical Properties of Variation in Graphite Form in Irons Having Varying Amounts of Ferrite and Pearlite in the Matrix Structure and the Use of ND Tests in the Assessments of Mechanical Properties of Cast Irons. AFS Trans., 80-09, 21-50.
  • 6. Lee, S.C., Suen, J.-M., 1989. Ultrasonic ND Evaluation of Matrix Structures and Nodularity in Cast Irons. Met. Trans. A, Vol. 20A, pp. 2399-2407.10.1007/BF02666675
  • 7. Lerner, Y., Brestel, P., 1996. Ultrasonic Testing Predicts Casting Properties. Advanced Materials and Processes, 11, 39-41.
  • 8. Liu, Q., Jiang, A., Wang, J., Shi, D., 2018. Influence Factors for the Determination of Vermicular Graphite Ratio in Cast Iron Measured by Ultrasonic Method. Materials Transactions, 59(7), 1186-1191.10.2320/matertrans.M2018083
  • 9. Ono, K., 2020. A Comprehensive Report on Ultrasonic Attenuation of Engineering Materials, Including Metals, Ceramics, Polymers, Fiber-Reinforced Composites, Wood, and Rocks, Appl. Sci., 10, 2230.10.3390/app10072230
  • 10. Orlowicz, W., Opiekun, Z., 1995. Ultrasonic Detection of Microstructure Changes in Cast Iron. Theoretical and Appl. Fracture Mech., 22, 9-16.10.1016/0167-8442(94)00043-Z
  • 11. Skrbek, B., 2006. Using of ultrasound to evaluation of quality at cast iron casts. Slévarenství, 54, 9, 334-339. (in Czech)
  • 12. Tupaj, M., Orłowicz, A.W., Mróz, M., Kupiec, D. et al., 2020. Ultrasonic Testing of Vermicular Cast Iron Microstructure. Archives of Foundry Engineering, 20(4), 36-40.
  • 13. Ulewicz, R., Nový, F., Selejdak, J., 2014. Fatigue strength of ductile iron in ultra-high cycle regime. Advanced Materials Research, 874, 43-48.10.4028/www.scientific.net/AMR.874.43
Uwagi
Opracowanie rekordu ze środków MEiN, umowa nr SONP/SP/546092/2022 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2022-2023).