PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The influence of temperature changes in activated sludge processes on ibuprofen removal efficiency

Identyfikatory
Warianty tytułu
PL
Wpływ zmian temperatury w procesach osadu czynnego na efektywność usuwania ibuprofenu
Języki publikacji
EN
Abstrakty
EN
The article presents results regarding the ibuprofen reduction rate at three various temperature values (8, 18 and 28 °C) which were conducted using a static test in accordance with the PN-C-04645 ‘Water and wastewater. Evaluation of partial biodegradation of anionic and non-ionic surface active substances. Initial test’ standard. A single study cycle including the analysis of ibuprofen degradation rate in specific temperature variants lasted 24 h. The activated sludge for tests was obtained from the aeration zone of a bioreactor localized in the Central Wastewater Treatment Plant in Poznan City (Poland), which was used for inoculation (1 g/dm3) of sterile samples with the medium and ibuprofen (10 mg/dm3) after appropriate pre-treatment (intense aeration for 5 h). The analysis procedure included the separation and concentration of analytes from biodegradation samples by means of solid phase extraction (SPE) and subsequent determination with high performance liquid chromatography coupled with mass spectrometry (LC-MS/MS) using an UltiMate 3000 RSLC liquid chromatogram (Dionex, USA) with a tandem API 4000 QTRAP mass spectrometer (Biosystem, MDS Sciex, USA). Both literature review as well as the conducted initial studies confirmed that the removal of ibuprofen proceeds more rapidly at higher temperature values. A higher retention rate also enhanced the reduction of ibuprofen concentration. A decrease of its concentration was observed after 24 h, which reached 40 and 50 % for temperature values of 8 and 18 °C, accordingly, whereas the highest reduction by approx. 65 % was noted at 28 °C.
Rocznik
Strony
357--366
Opis fizyczny
Bibliogr. 31 poz., wykr., tab.
Twórcy
  • Institute of Chemistry and Technical Electrochemistry, Poznan University of Technology, ul. Berdychowo 4, 61-131 Poznań, Poland, phone +48 61 665 2015
  • Institute of Environmental Engineering, Poznan University of Technology, ul. Berdychowo 4, 61-131 Poznań, Poland, phone +48 61 665 3496, fax +48 61 665 2439
autor
  • Institute of Environmental Engineering, Poznan University of Technology, ul. Berdychowo 4, 61-131 Poznań, Poland, phone +48 61 665 3496, fax +48 61 665 2439
  • Institute of Environmental Engineering, Poznan University of Technology, ul. Berdychowo 4, 61-131 Poznań, Poland, phone +48 61 665 3496, fax +48 61 665 2439
  • Institute of Environmental Engineering, Poznan University of Technology, ul. Berdychowo 4, 61-131 Poznań, Poland, phone +48 61 665 3496, fax +48 61 665 2439
  • Institute of Environmental Engineering, Poznan University of Technology, ul. Berdychowo 4, 61-131 Poznań, Poland, phone +48 61 665 3496, fax +48 61 665 2439
  • Institute of Environmental Engineering, Poznan University of Technology, ul. Berdychowo 4, 61-131 Poznań, Poland, phone +48 61 665 3496, fax +48 61 665 2439
  • Institute of Chemistry and Technical Electrochemistry, Poznan University of Technology, ul. Berdychowo 4, 61-131 Poznań, Poland, phone +48 61 665 2015
Bibliografia
  • [1] Eslami A, Amini MM, Yazdanbakhsh AR, Rastkari N, Mohseni-Bandpei A, Nasseri S, et al. Environ Monit Assess. 2015;187(12):1-15. DOI: 10.1007/s10661-015-4952-1.
  • [2] Salgado R, Noronha JP, Oehmen A, Carvalho G, Reis MA. Water Sci Technol. 2010;62(12):2862-2871. DOI: 10.2166/wst.2010.985.
  • [3] Yu CP, Roh H, Chu KH. Environ Sci Technol. 2007;41:486-492. DOI: 10.1021/es060923f.
  • [4] Landers TF, Cohen B, Wittum TE, Larson EL. Public Health Rep. 2012;127,1:4-22. DOI: 10.1177/003335491212700103.
  • [5] Szymonik A, Lach J, Malińska K. Ecol Chem Eng S. 2017;24(1):65-85. DOI: 10.1515/eces-2017-0006.
  • [6] Langenhoff A, Inderfurth N, Veuskens T, Schraa G, Blokland M, Kujawa-Roeleveld K, et al. BioMed Res Int. 2013:1-9. DOI: 10.1155/2013/325806.
  • [7] Kosjek T, Heath E, Kompare B. Anal Bioanal Chem. 2007;387(4):1379-1387. DOI: 10.1007/s00216-006-0969-1.
  • [8] Zając A, Kruszelnicka I, Ginter-Kramarczyk D, Zembrzuska J. Przem Chem. 2016;95:263-268. DOI: 10.15199/62.2016.2.15.
  • [9] Liu J, Dan X, Lu G, Shen J, Wu D, Yan Z. Ecotoxicol Environ Saf. 2018;15;154:214-220. DOI: 10.1016/j.ecoenv.2018.02.052.
  • [10] Melvin SD, Cameron MC, Lanctôt CM. J. Toxicol Environ Health A. 2014;77(6): 337-345. DOI: 10.1080/15287394.2013.865107.
  • [11] Zuriaga E, Lomba L, German B, Lanuza PM, Aldea L, Ribate MP, et al. Chem Ecol. 2019;35(2):102-114, DOI: 10.1080/02757540.2018.1540608.
  • [12] Zhou Y, Wu S, Zhou H, Huang H, Zhao J, Deng Y. Environ Int. 2018;121(1):523-537. DOI: 10.1016/j.envint.2018.09.041.
  • [13] Directive 2013/39/EU of the European Parliament and of the Council of 12 August 2013 as regards priority substances in the field of water policy. https://eur-lex.europa.eu/legal-content/EN/TXT/HTML/?uri=CELEX:32013L0039&from=EN.
  • [14] Ginter-Kramarczyk D, Zając A, Kruszelnicka I, Zembrzuska J, Budnik I. Przem Chem. 2013;92:596-600.
  • [15] Larsson DGJ. Philos Trans R Soc B. 2014;369:1-7. DOI:10.1098/rstb.2013.0571.
  • [16] Cinà P, Bacci G, Arancio W, Gallo G, Fani R, Puglia AM, et al. Bioresour Technol. 2019;282:254-261. DOI: 10.1016/j.biortech.2019.03.018.
  • [17] Küummerer K. Annual Rev Environ Resour. 2010;35:57-75. DOI: 10.1146/annurev-environ-052809-161223.
  • [18] Gilbert N. Nature. 2011;476:265. DOI: 10.1038/476265a.
  • [19] Kujawa-Roeleveld K, Schuman E, Grotenhuis T, Kragić D, Mels A, Zeeman G. Biodegradability of human pharmaceutically active compounds (PhAC) in biological systems treating source separated wastewater streams. Third SWITCH Scientific Meeting, Brazil, 2008. http://www.switchurbanwater.eu/outputs/pdfs/W41_GEN_RPT_D4.1.3_Biodegradability_and_fate_of_phamarceutical_compounds.pdf.
  • [20] Kruglova A, Kråkström M, Riska M, Mikola A, Rantanen P, Vahala R. Bioresour Technol. 2016;214:81-88. DOI: 10.1016/j.biortech.2016.04.037.
  • [21] Kruglova A, Ahlgren P, Korhonen N, Rantanen P, Mikola A, Vahala R. Sci Total Environ. 2014;499:394-401. DOI: 10.1016/j.scitotenv.2014.08.069.
  • [22] Ebele AJ, Abdallah MAE, Harrad S. Emerg Contam.2017;3:1-16. DOI: 10.1016/j.emcon.2016.12.004.
  • [23] Fernandez-Fontaina E, Omil F, Lema JM, Carballa M. Water Res. 2012;46:5434-5444. DOI: 10.1016/j.watres.2012.07.037.
  • [24] Clara M, Kreuzinger N, Strenn B, Gans O, Kroiss H. Water Res. 2015;39:97-106. DOI: 10.1016/j.watres.2004.08.036.
  • [25] Chen X, Vollertsen J, Nielsen JL, Dall AG, Bester K. Ecotoxicology. 2015;24:2073-2080. DOI: 10.1007/s10646-015-1548-z.
  • [26] Falås P, Baillon-Dhumez A, Andersen HR, Ledin A, la Cour Jansen J. Water Res. 2012;46:1167-1175. DOI: 10.1016/j.watres.2011.12.003.
  • [27] Prasertkulsak S, Chiemchaisri C, Chiemchaisri W, Itonaga T, Yamamoto K. Chemosphere. 2016;150:624-631. DOI: 10.1016/j.chemosphere.2016.01.031.
  • [28] Kimura K, Hara H, Watanabe Y. Water Sci Technol. 2010;62:1084-1089. DOI: 10.2166/wst.2010.356.
  • [29] Caracciolo AB, Topp E, Grenni P. J Pharm Biomed Anal. 2015;106:25-36. DOI: 10.1016/j.jpba.2014.11.040.
  • [30] PN-C-04645. 2001. Woda i ścieki. Badanie biodegradacji częściowej anionowych i niejonowych substancji powierzchniowo czynnych. Test wstępny. (Polish Standard. PN-C-04645:2001. Water and wastewater. The study of partial biodegradation of anionic and non-ionic surface active substances. The preliminary test). http://sklep.pkn.pl/pn-c-04645-2001p.html.
  • [31] PN-ISO 15705:2005. Jakość wody. Oznaczanie indeksu chemicznego zapotrzebowania tlenu (SP-ChZT). (Polish Standard. PN-ISO 15705:2005 PN-ISO 15705:2005 Water quality. Determination of chemical oxygen demand index (COD). http://sklep.pkn.pl/pn-iso-15705-2005p.html.
Uwagi
PL
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-65908be6-49d9-4802-968a-7a3dd2899afa
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.