PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Development and validation of a reversed-phase liquid chromatography method for the quantification of meloxicam in liposomes

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In the present study, we have developed and validated an analytical method for the determination of meloxicam in liposomes using high-performance liquid chromatography-ultraviolet (HPLC-UV). Chromatographic separation was carried out on an Ascentis RP amide C16 column selecting a mobile phase composed of acetonitrile-0.3% formic acid solution (40:60, v/v) adjusted at pH 2.8. The mobile phase flow rate selected was 0.5 mL min -1 and UV detection at 355 nm. Piroxicam was chosen as internal standard. All the analyses were performed at temperatures of 40.0 ± 0.5°C. The calibration curve was linear over the range 18–420 ng mL -1. Relative standard deviation (RSD) for precision was <1.03%. Accuracy ranged between 98.53% and 101.41% with RSD lower than 1.5%. LOD and LOQ were 5 ng mL -1 and 15 ng mL -1, respectively. The method was simple, rapid, and easy to apply, making it very suitable for routine analysis of meloxicam in liposomes. The method could also be used with reliability for the determination of meloxicam in other pharmaceutical dosage forms.
Słowa kluczowe
Rocznik
Strony
639--653
Opis fizyczny
Bibliogr. 17 poz., rys., tab.
Twórcy
autor
  • Universidad CEU San Pablo Departamento de Ciencias Farmacéuticas y de la Alimentación, Área de Farmacia y Tecnología Farmacéutica, Facultad de Farmacia 28668 Madrid Spain
autor
  • Universidad Complutense de Madrid Departamento de Química Física II, Facultad de Farmacia 28040 Madrid Spain
autor
  • Universidad Complutense de Madrid Departamento de Farmacia y Tecnología Farmacéutica, Facultad de Farmacia 28040 Madrid Spain
autor
  • Universidad Complutense de Madrid Departamento de Farmacia y Tecnología Farmacéutica, Facultad de Farmacia 28040 Madrid Spain
  • Universidad Complutense de Madrid Departamento de Farmacia y Tecnología Farmacéutica, Facultad de Farmacia 28040 Madrid Spain
Bibliografia
  • [1] R.N. Rao, S. Meena, and A.R. Rao, J. Pharm. Biomed. Anal., 39, 349–363 (2005)
  • [2] N.B. Naidu, K.P Chowdary, KVR Murthy, V. Satyanarayana, A.R. Hayman, and G. Becket, J. Pharm. Biomed. Anal., 35, 75–86 (2004)
  • [3] A.P. Goldman, C.S. Williams, H.M. Sheng, L.W. Lamps, V.P. Williams, M. Pairet, J.D. Morrow, and R.N. DuBois, Carcinogenesis, 19, 2195–2199 (1998)
  • [4] D. Turck, W. Roth, and U. Busch, Brit. J. Rheumatol., 35, 13–19 (1996)
  • [5] H.J. Hussey and M.J. Tisdale, Int. J. Cancer, 87, 95–100 (2000)
  • [6] Y. Tsubouchi, S. Mukai, Y. Kawahito, R. Yamada, M. Cono, K. Inoue, and H. Sano, Anticancer Res., 20, 2867–2872 (2000)
  • [7] T. Naruse, Y. Nishida, K Hosono, and N. Ishiguro, Carcinogenesis, 27, 584–592 (2006)
  • [8] T. Velpandian, J. Jaiswal, R.K. Bhardwaj, and S.K. Gupta, J. Chromatogr. B Biomed. Sci. Appl., 738, 431–436 (2000)
  • [9] B. Dasandi, H. Shivaprakash, H, Saroj, and K.M. Bhat, J. Pharm. Biomed. Anal., 28, 999–1004 (2002)
  • [10] J.W. Bae, M.J. Kim, C.G. Jang, and S.Y. Lee, J. Chromatogr. B, 859, 69–73 (2007)
  • [11] A. Medvedovici, F. Albu, C. Georgita, C. Mircioiu, and V. David, Arzneimittelforschung, 55, 326–331 (2005)
  • [12] J.L. Wiesner, A.D. de Jager, F.C. Sutherland, H.K. Hundt, K.J. Swart, and A.F. Hundt, J. Els, J. Chromatogr. B, 785, 115–121(2003)
  • [13] H.M. Rigato, G.D. Mendes, N.C. Borges, and R.A. Moreno, Int. J. Clin. Pharmacol. Ther., 44, 489–498 (2006)
  • [14] Y. Yuan, X. Chen, and D. Zhong, J. Chromatogr. B, 852, 650–654 (2007)
  • [15] A. Madni, M. Ahmad, M. Usman, M.M. Zubair, M. Qamar-Uz-Zaman, H.M Shoaib, A. Munir, S.A. Khan, M.N. Amir, and M.S. Qureshi, J. Chem. Soc. Pak., 32, 654–661 (2012)
  • [16] A.D. Bangham, M.M. Standish, and J.C. Watkins, J. Mol. Biol., 13, 238–252 (1965)
  • [17] International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH), Q2B, Guideline on Validation of Analytical Procedure-Methodology, London, 1996
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-62ff8c03-8f54-4b41-82f8-25145f2793b8
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.