Wytyczne projektowania systemów odymiania mechanicznego w obiektach wielkokubatutowych z atrium wg normy NFPA 92 Standard for Smoke management Systems in Malls, Atria, and Large Spaces, 2012 Edition, część 2

Treść / Zawartość
Identyfikatory
Warianty tytułu
EN
Mechanical Smoke Management Design Principles in Large Volume Spaces witch Atrium Based On Nfpa 92 Standard for Smoke management Systems in Malls, Atria, and Large Spaces, 2012 Edition
Języki publikacji
PL
Abstrakty
EN
All concept calculations that are made for smoke management system need to be done based on design building shape analysis. Very important is to verify all manual calculations by CFD on a preliminary design stage and by hot smoke tests on as-build stage. CFD simulations are very helpful in verification of assumed hot smoke exhaust efficiency. Hot smoke tests are also very important, especially in verification of smoke control system that detects of fire and controls many important devices like smoke curtain, fire dumpers and shutters or any other in case of fire.
Rocznik
Tom
Strony
78--99
Opis fizyczny
Bibliogr. 15 poz., rys., tab.
Twórcy
autor
  • Zakład Podstaw Budownictwa i Materiałów Budowlanych, SGSP
autor
  • Zakład Podstaw Budownictwa i Materiałów Budowlanych, SGSP
autor
  • Zakład Podstaw Budownictwa i Materiałów Budowlanych, SGSP
Bibliografia
  • [1] Rozporządzenie ministra Spraw Wewnętrznych i Administracji z 7 czerwca 2010 r. w sprawie ochrony przeciwpożarowej budynków, innych obiektów budowlanych i terenów (DzU nr 109, poz. 719).
  • [2] Materiały konferencyjne, Ochrona przeciwpożarowa, Zakopane 2010, wydanie 2010.
  • [3] Ustawa Prawo Budowlane z . 7 lipca 1994 r. (DzU z 2003, nr 207, poz. 2016 z późn. zm.)
  • [4] NFPA 92 Standard for Smoke management Systems in Malls, Atria, and Large Spaces, 2012 Edition.
  • [5] Harrison R., Smoke Control In Atrium Buildings: A Study of the Thermal Spill Plume.
  • [6] BS 7346-4: 2003 Components for smoke and heat control systems. Part 4: Functional recommendations and calculation methods for smoke and heat exhaust ventilation systems, employing steady- state design fires-Code of practice.
  • [7] Harrison R. and Spearpoint M. J., Entrainment of air into a balcony spill plume, Journal of Fire Protection Engineering, vol. 16, no. 3, pp 211-245, 2006.
  • [8] Morgan H.P. and Marshall N.R., Smoke hazards in covered multi-level shopping malls: an experimentally-based theory for smoke production, BRE Current Paper 48/75, BRE, 1975.
  • [9] Mayfield C., Hopkins D., Design fires for use in fire safety engineering, BRE 2011.
  • [10] Ostapiuk Ł., praca magisterska „Analiza porównawcza wyników uzyskanych z modeli rozprzestrzeniania się dymu i ciepła w warunkach pożaru wykorzystujących technikę CFD oraz normy NFPA 92 i BS 7346-4: 2003 na przykładzie system oddymiania wybranego obiektu atrialnego.
  • [11] AS 4391-1999 Australian Standard™ Smoke management systems-Hot smoke test.
  • [12] VDI 6019-2:2009 – Engineering Methods For The Dimensioning Of Systems For The Removal Of Smoke From Buildings – Engineering Methods.
  • [13] PD 7974-2:2002 Aplication of fire safety engineering principles to the design of buildings. Part 2: Spread of smoke and toxic gases within and beyound the enclosure of origin (Sub-system 2).
  • [14] TR 12101-5 Smoke and heat control systems - Part 5: Guidelines on functional recommendations and calculation methods for smoke and heat exhaust ventilation systems.
  • [15] Milke J.A. Smoke management in covered malls and atria. Chapter 13, Section 4, SFPE Handbook of Fire Protection Engineering, 3rd Edition, NFPA, Quincy, MA, 2002.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-61f1568e-e9ee-432a-820d-c29489015e50