Monitorowanie zanieczyszczenia środowiska za pomocą cienkich elektrod metalowych przygotowanych przez fizyczne osadzanie z fazy gazowej
Języki publikacji
Abstrakty
This work is focused on environmental pollution monitoring utilizing thin metal electrodes on glassy/ceramic substrates prepared by physical vapour deposition. Besides others, it is well known that environmental pollution on electrical insulation is one of the problems faced by distribution utilities and electricity transmission system. Due to this reason there is a need to deal with monitoring of environmental pollution as it strongly influences their capability to withstand the high-voltage stress without the breakdown. It is the aim of present work to propose new system for environmental pollution monitoring based on application of extra-thin metal electrodes. The influence of morphology and chemical composition of pollutants on the surface resistance and conductivity of selected insulators is also discussed.
Artykuł dotyczy monitorowania zanieczyszczenia środowiska za pomocą cienkich elektrod metalowych na szklanych/ceramicznych podłożach przygotowanych przez fizyczne osadzanie z fazy gazowej. Widomym jest, że zanieczyszczenie środowiska odpadami izolacji elektrycznej jest jednym z problemów, przed którymi stoją firmy dystrybucyjne i system przesyłu energii elektrycznej. Z tego powodu istnieje potrzeba monitorowania zanieczyszczenia środowiska, ponieważ ma to duży wpływ niezawodność sieci wysokiego napięcia i jej awaryjność. Celem przedstawionych prac jest zaproponowanie nowego systemu monitorowania zanieczyszczenia środowiska w oparciu o zastosowanie bardzo cienkich elektrod metalowych. Omówiono także wpływ morfologii i składu chemicznego zanieczyszczeń na rezystancję powierzchniową i przewodnictwo wybranych izolatorów.
Czasopismo
Rocznik
Tom
Strony
13--16
Opis fizyczny
Bibliogr. 6 poz., rys., wykr., zdj.
Twórcy
autor
- Institute of Geotechnics, Slovak Academy of Sciences, Watsonova 45, 04001, Košice, Slovakia
autor
- Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 04200, Košice, Slovakia
autor
- Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 04200, Košice, Slovakia
autor
- Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 04200, Košice, Slovakia
autor
- Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 04200, Košice, Slovakia
autor
- Faculty of Electrical Engineering and Informatics, Technical University of Košice, Letná 9, 04200, Košice, Slovakia
autor
- Institute of Geotechnics, Slovak Academy of Sciences, Watsonova 45, 04001, Košice, Slovakia
Bibliografia
- 1. “Secure, Clean and Efficient Energy - Horizon 2020 - European Commission”, Horizon 2020. [Online]. Available at: http://://ec.europa.eu/programmes/horizon2020/en/h2020- section/secure-clean-and efficient-energy. [Cit: 21-okt-2015].
- 2. uropean Commission, Ed., Energy roadmap 2050. Luxembourg: Publications Office of the European Union, 2012.
- 3. European Commission, Ed., Energy infrastructure. Priorities for 2020 and beyond - A Blueprint for an integrated European energy network. Luxembourg: Publications Office of the European Union, 2011.
- 4. M. Amin, S. Amin, and M. Ali, “Monitoring of leakage current for composite insulators and electrical devices,” Review on Advanced Materials Science, vol. 21, no. 1, pp. 75–89, 2017.
- 5. IEC 60071-2: 1996, Insulation co-ordination – Part 2: Application guide. International standard.
- 6. IEC 507: 1991, Artificial pollution tests on high-voltage insulators to be used on a.c. systems. International standard.
Uwagi
Opracowanie rekordu ze środków MNiSW, umowa Nr 461252 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2020).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-60d9a200-c4af-4777-868d-d2cf1ae3947d