Using non-destructive methods for measurementof reinforcement corrosion in practice

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Zastosowanie w praktyce metod nieniszczących do pomiaru korozji zbrojenia
Języki publikacji
EN
Abstrakty
EN
The paper deals with a description of selected methods, by which it is possible to detect the corrosion loss of steel reinforcement, based on the recorded change in electrical resistance at the time. By verification the suitability of using these methods in previous researches [1, 5, 7, 15] we prepared new samples with required dimensions withinproject APVV- 14-0772. Formation and progression of corrosion [2, 3, 6, 8–10, 13, 14] we will monitor on samples of reinforcing steel in the form of separate bars and in bars embedded in concrete. There will be also used samples of structural steel. Part of the samples will be exposed to the atmospheric environment and the remaining samples will be subjected to accelerated tests in climatic chambers. Real type of corrosion (uniform corrosion, non-uniform corrosion, pitting corrosion, etc.) of samples will be assessed visually and by means of scanning electron microscopy (SEM).
PL
W artykule opisano wybrane metody umożliwiające wykrywanie korozji stali zbrojeniowej na podstawie zarejestrowanych zmian oporności elektrycznej w czasie. Po weryfikacji przydatności stosowanych w poprzednich badaniach metod [1, 5, 7, 15] w ramach projektu APVV-14- 0772 przygotowane zostały kolejne próbki o odpowiednich wymiarach. Początek oraz postęp korozji [2, 3, 6, 8–10, 13, 14] będą monitorowane na próbkach stali zbrojeniowej, zarówno na samych prętach, jak i na prętach umieszczonych w betonie. Zostaną również wykorzystywane próbki ze stali konstrukcyjnej. Część próbek będzie wystawiona na działanie środowiska atmosferycznego, a pozostałe zostaną poddane przyspieszonym testom w komorach klimatycznych. Typ korozji (jednolita, nierównomierna, wżerowa, itd.) próbek będzie określany wizualnie oraz za pomocą mikroskopu skaningowego (SEM).
Rocznik
Tom
Strony
55--58
Opis fizyczny
Bibliogr. 15 poz., rys., tab
Twórcy
autor
  • University of Žilina, Department of Structures and Bridges
autor
  • University of Žilina, Department of Structures and Bridges
autor
  • University of Žilina, Department of Structures and Bridges
autor
  • University of Žilina, Department of Measurement and Applied Electrical Engineering
autor
  • University of Žilina, Department of Measurement and Applied Electrical Engineering
autor
  • Warsaw University of Technology (branch in Plock), Institute of Building
Bibliografia
  • [1] Andrade C., C. Alonso. 1996. Corrosion rate monitoring in the laboratory and on-site”. Construction and Building Materials 10 : 315–328.
  • [2] Bilčik J., I. Holly. 2012. “Effect of reinforcement corrosion on reliability”. Journal Beton TKS 3 : 16–20.
  • [3] Bujňak J., R. Hlinka, J. Odrobiňak, J. Vičan. 2012. „Diagnostics and evaluation of footbridges”. Procedia Engineering, 40 : 56–61.
  • [4] http://www.shmu.sk/sk/?page=1&id=oko_imis_map_so2&p=SO2
  • [5] Jaśniok Tomasz, Mariusz Jaśniok, Adam Zybura. 2013. “Studies on corrosion rate of reinforcement in reinforced concrete water tanks”. Ochrona przed Korozją 56 (5) : 227–234.
  • [6] Kolisko J., P. Huňka, S. Řehaček. 2014. “Bridge Pavla Wonky in Pardubice. Diagnostics of Corrosion Condition of External Cables and Use of Special Materials for Proposal of Treatment”. Advanced Materials Research 919-921 : 619–624.
  • [7] Koteš Peter, Miroslav Brodňan, Katarina Šlopkova. 2008. “Simulation of corrosion of reinforcement in reinforced concrete”. International RILEM Symposium on Concrete Modelling – CONMOD 08, CD, Delft (The Netherlands) : 761–766.
  • [8] Krykowski Tomasz. 2012. Modelowanie uszkodzenia otuliny wywołanego korozja zbrojenia w żelbecie. Studia z zakresu inżynierii, Nr 78, 173. Warszawa : Polska Akademia Nauk, Komitet inżynierii lądowej i wodnej.
  • [9] Odrobiňak Jaroslav., Richard Hlinka. 2016. “Degradation of steel footbridges with neglected inspection and maintenance”. Procedia Engineering 156 : 304–311.
  • [10] Paulik P., M. Bačuvčik, P. Ševčik., I. Janotka. 2016. “Material properties and carbonation depths measured on seven, more than a 100-years old, concrete bridges in Slovakia”. Procedia Engineering 156 : 326–333.
  • [11] STN EN ISO 12944-2 Paints and varnishes. Corrosion protection of steel structures by protective paint systems. Part 2: Classification of environments, UNMS Bratislava, 2001.
  • [12] STN EN ISO 9226 Corrosion of metals and alloys – Corrosivity of atmospheres – Determination of corrosion rate of standard specimens for the evaluation of corrosivity (ISO 9226:2012), UNMS Bratislava, 2012.
  • [13] Vaněrek J., R. Drochytka. 2002. “Detection of corrosion rate of steel in reinforced concrete”. 3rd International Conference Concrete and Concrete Structures, 1st ed. Žilina, Faculty of Civil Engineering : 137–142.
  • [14] Vořechovska D., J. Podroužek, M. Chroma, P. Rovnanikova, B. Teply. 2009. “Modeling of chloride concentration effect on reinforcement corrosion”. Journal Computer-Aided Civil and Infrastructure Engineering 2 : 446–458.
  • [15] Živica Vladmir. 2000. “Utilisation of electrical resistance method for the evaluation of the state of steel reinforcement in concrete and the rate of its corrosion”. Construction and Building Material 14 : 351–358.