The article describes the study on water meters after their five-year period of operation. Water meters were tested at a certification stand to check for possible reading errors. The following devices have been included in the study: water meters with a diameter of 20 mm (single-jet, multi-jet and volumetric) as well as single-jet and screw water meters with a diameter of 50 mm. The faulty water meters were disassembled to identify causes of damage specific for various types of water meters. The percentage of faulty water meters differed among individual types of water meters, as well as among single-jet water meters of different manufacturers. The tests carried out should verify the actual errors of water meter readings during and after operation, and check whether the errors vary for different types of water meters. After many years of operational experience, it may be concluded that water meters, if lose their correct metrological properties, they usually show a smaller values than the actual flow. In such cases, faulty water meters cause the apparent water loss. Based on the study the authors found that volumetric water meters had the highest reliability among household water meters while screw water meters among industrial water meters. The studies have confirmed that damaged water meters can contribute to higher apparent water losses.
Słowa kluczowe
Czasopismo
Rocznik
Tom
Strony
63--75
Opis fizyczny
Bibliogr. 11 poz., il., wykr.
Twórcy
autor
- The Krakow Waterworks Senatorska street 1, Cracow, 30-106, Poland
autor
- Cracow University of Technology Faculty of Environmental Engineering Warszawska street 24, Cracow, 31-155, Poland
Bibliografia
- Bergel T., Kulig M. (2010), Zapobieganie stratom wody wodociągowej, ”Wodociągi-Kanalizacja” No. 4(74), p. 58-61
- Cichoń T. (2010), Ocena wieloaspektowa niezawodności systemu opomiarowania poboru i strat wody na podstawie doświadczeń eksploatacyjnych, rozprawa doktorska, Kraków
- Cichoń T. (2013), Analiza eksploatacji wodomierzy z uwzględnieniem aspektu niezawodnościowego, ”INSTAL” No. 12, p. 74
- Cichoń T., Królikowska J. (2016), Ewolucja procesu odczytu wodomierzy na podstawie doświadczeń Wodociągów Krakowskich, ”INSTAL” No. 12
- Cichoń T., Królikowska J. (2016), Reduction of water losses through metering of water supply network districts, Environmental Engineering V: proceedings of the Fifth National Congress of Environmental Engineering, Poland, Lublin, p. 62
- Geresz E. (2011), Systemy do zdalnego odczytu wodomierzy – dlaczego warto?, ”Ochrona Środowiska” No. 2
- Koral W. (2017), Zdalne odczyty wodomierzy – gdzie jesteśmy, dokąd zmierzamy?, ”Wodociągi i Kanalizacja” No. 3
- Koral W. (2006), Wymagania wobec wodomierzy w dyrektywie MID z punktu widzenia odbiorcy końcowego, ”INSTAL” No. 11, p. 48-49
- Tuz P.K., Gwoździej-Mazur J. (2012), Problemy z metrologią wodomierzy, ”Rynek Instalacyjny” No. 9, p. 75-78
- Tuz P.K. (2011), Wodomierze wolumetryczne (objętościowe) po 5 latach eksploatacji w sieci wodociągowej, ”Civil And Environmental Engineering” No. 2, p. 175-181
- Rozporządzenie Ministra Gospodarki z dnia 23 października 2007 r. w sprawie wymagań, którym powinny odpowiadać wodomierze, oraz szczegółowego zakresu sprawdzeń wykonywanych podczas prawnej kontroli metrologicznej tych przyrządów pomiarowych, Dz.U. nr 209 poz. 1513