One of the important issues of energy policy of EU and Ukraine is an economical use of energy. The infrared heaters are an effective way to provide temperature regime in industrial premises. For providing microclimate parameters in industrial premises is important to consider simultaneously heating and ventilation systems. These studies related to determining the impact of air velocity, power of infrared heater, the degree of blackness of protecting structures on temperature regime in working area of industrial premises. Graphic and empirical dependence of air temperature in the working area were obtained. These results depended on radiation intensity, degree of blackness of surface exposure and different air velocity. The results of experimental studies have shown that with increasing air velocity temperature distribution in the cross section acquires a uniform character.
PL
Jednym z ważniejszych zagadnień polityki energetycznej UE i Ukrainy jest ekonomiczne użytkowanie energii. Skutecznym sposobem zapewnienia odpowiedniej regulacji temperatury w zakładach produkcyjnych jest wykorzystanie grzejników podczerwieni w systemach grzewczych. Dla zapewnienia odpowiednich parametrów mikroklimatu w obiektach przemysłowych ważne jest, aby rozważyć zastosowanie kompleksowego systemu ogrzewania i wentylacji. Przeprowadzone badania były związane z określeniem prędkości strumienia powietrza, mocy promiennika podczerwieni oraz współczynnika emisyjności dla osłon w danym reżimie temperaturowym w obszarze roboczym w zakładach przemysłowych. Otrzymano graficzną i empiryczną zależność temperatury od natężenia promieniowania, współczynnika emisyjności przy różnych prędkościach powietrza. Wyniki badań eksperymentalnych pokazały, że zwiększając prędkość powietrza uzyskuje się bardziej jednolity charakter rozkładu temperatury w przekroju poprzecznym.
Rocznik
Strony
43--46
Opis fizyczny
Bibliogr. 5 poz., il., 1 fot.
Twórcy
autor
  • Lviv Polytechnic National University, Institute of Building and Environmental Engineering, Heat, Gas supply and Ventilation Department, Ukraine, Lviv - 13, St. Bandery street, 12, 79013
autor
  • Lviv Polytechnic National University, Institute of Building and Environmental Engineering, Heat, Gas supply and Ventilation Department, Ukraine, Lviv - 13, St. Bandery street, 12, 79013
  • Lviv Polytechnic National University, Department of Labor Protection, Ukraine, Lviv - 13, St. Bandery street, 12, 79013
autor
  • Technical University in Kosice, Institute of Architectural Engineering, Faculty of Civil Engineering, Laboratory of Architectural Engineering, Slovak Republic, Kosice, Vysokoškolská 4, 042 00
Bibliografia
  • [1] Fisk W., Rosenfeld A., Estimates of Improved Productivity a Health from Better Indoor Environments, National Library and U.S. Department of Energy, 1997, 27-35
  • [2] Shcherbovskykh S., Spodyniuk N., Stefanovych T., Zhelykh V., Shepitchak V., Development of a reliability model to analyse the causes of a poultry module failure. Eastern-European Journal of Enterprise Technologies, 3(82)2016, 4-9
  • [3] Spodyniuk N., Kapalo P., Energicky efektívne systémy infračerveného vykurovania s utilizáciou tepla, Plynár, vodár, kúrenár, klimatizácia 3(8)2010, 27-29
  • [4] Offerman F.J., Int-Hout D., Ventilation effectiveness and ADPI measurements of a forced air heating system, ASHARE Transactions 1(94)1988, 694-704
  • [5] Zhelykh V., Ulewicz M., Spodyniuk N., Shapoval S., Shepitchak V., Analysis of the Processes of Heat Exchange on Infrared Heater Surface, Diagnostyka 3(17)2016, 81-85
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-5e1bf1ea-2f3a-4731-a0d2-59510cf28160
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.