PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Calibration and applications of modern track detectors CR-39/PM-355 in nuclear physics and high temperature plasma experiments

Treść / Zawartość
Identyfikatory
Warianty tytułu
Konferencja
International Conference on Recent Developments and Applications of Nuclear Technologies (15-17.09 2008 ; Białowieża, Poland)
Języki publikacji
EN
Abstrakty
EN
Solid-state nuclear track detectors (SSNTDs) have been used for the registration of charged particles practically since the beginning of the 1960s, when a new class of detectors, called dielectric track detectors, were discovered. The paper describes applications of the SSNTDs type PM-355 for diagnostics of fusion-reaction protons and other ions emitted from plasma focus (PF) devices, tokamaks and laser facilities. Such detectors were also used in biomedical experiments for beam profile measurements. The results of our calibration studies of SSNTDs as well as charged particle- and biomedical measurements, which were carried out within different facilities, are presented.
Czasopismo
Rocznik
Strony
15--19
Opis fizyczny
Bibliogr. 6 poz., rys.
Twórcy
  • The Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock/Świerk, Poland, Tel.: +48 22 7180536, Fax: +48 22 7793481
  • The Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock/Świerk, Poland, Tel.: +48 22 7180536, Fax: +48 22 7793481
autor
  • The Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock/Świerk, Poland, Tel.: +48 22 7180536, Fax: +48 22 7793481
autor
  • The Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock/Świerk, Poland, Tel.: +48 22 7180536, Fax: +48 22 7793481
autor
  • Department of Nuclear Methods of Material Engineering, Institute of Nuclear Chemistry and Technology, 16 Dorodna 16 Str., 03-195 Warsaw, Poland
  • The Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock/Świerk, Poland and Institute of Plasma Physics and Laser Microfusion, 23 Hery 23 Str., 01-497 Warsaw, Poland
autor
  • Institute of Plasma Physics and Laser Microfusion, 23 Hery 23 Str., 01-497 Warsaw, Poland
  • The Andrzej Soltan Institute for Nuclear Studies, 05-400 Otwock/Świerk, Poland, Tel.: +48 22 7180536, Fax: +48 22 7793481
Bibliografia
  • 1. Badziak J, Jabłoński S, Parys P et al. (2008) Ultraintense proton beams from laser-induced skin-layer ponderomotive acceleration. J Appl Phys 104:063310
  • 2. Czub J, Banaś D, Braziewicz J et al. (2006) An irradiation facility with a horizontal beam for radiobiological studies. Radiat Prot Dosim 122:207–209
  • 3. England JBA (1974) Techniques in nuclear structure physics. Wiley, New Jork
  • 4. Sadowski MJ, Scholz M (2008) The main issues of research on dense magnetized plasmas. Plasma Sources Sci Technol 17:024001(13pp)
  • 5. Szydłowski A, Banaszak A, Czyżewski T et al. (2001) Advantage of PM-355 nuclear track detector in light-ion registration and high-temperature plasma diagnostics. Radiat Meas 34:325–329
  • 6. Szydłowski A, Malinowska A, Sadowski MJ et al. (2008) Measurement of fusion-reaction protons in TEXTOR tokamak plasma by means of solid-state nuclear track detectors of the CR-39/PM-355 type. Radiat Meas 43:S290–S294
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-5dcbec85-6b30-475c-8d3b-fbb3ac6e1586
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.