Investigating the effects of various suturing parameters on the leakage from the intestinal anastomosis site: finite element analyses

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
In this work, effects of various parameters, including regularity of sewing, distance of holes from the edge of the tissue (D), distance between holes (L), suturing pattern, and material and size of the suture on the leakage of human large intestine anastomosis site were investigated, using finite element method (FEM). The effects of various parameters of suturing on leakage were investigated in four different steps: 1. regularity of suturing; 2. variations in D (small, medium and large), and L (small, medium and large); 3. suturing pattern; and 4. material and size of the suture. The models mimicked two sides of human large intestine tissue, sewn together. By considering a 50 mm displacement on right-side free edge of tissue, the surface areas of the gaps created around the holes were calculated, and a gap surface area equals to, or greater than 0.07 mm2 was considered as the leaking specimen. Results showed that in the case of irregular suturing, compared to the regular one, the likelihood of leakage increases. Additionally, in the cases with large D and medium L, the likelihood of leakage decreases. It was found that zigzag pattern has less leakage probability compared with simple continuous and interrupted patterns. Furthermore, by increasing the diameter and elastic modulus of the suture, the likelihood of leakage will increase. Results of this study are in agreement with experimental evidences.
Twórcy
autor
  • Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
  • Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
  • Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
Bibliografia
  • [1] Martel G, Boushey RP. Stapled small bowel anastomoses. Oper Tech Gen Surg 2007;9(1):13–8.
  • [2] Buchberg BS, Masoomi H, Bergman H, Mills SD, Stamos MJ. The use of a compression device as an alternative to hand-sewn and stapled colorectal anastomoses: Is three a crowd? J Gastrointest Surg 2011;15(2):304–10.
  • [3] Chen S, Yang B, He J-h, Zhang Y-c, Lai D-m. Randomized trial on the application of biofragmentable anastomosis ring in intestinal anastomosis. Chin Med J 2009;122(15):1755–8.
  • [4] Galizia G, Lieto E, Castellano P, Pelosio L, Imperatore V, Canfora F, et al. Comparison between the biofragmentable anastomosis ring and stapled anastomoses in the extraperitoneal rectum: a prospective, randomized study. Int J Colorectal Dis 1999;14(6):286–90.
  • [5] Hanson RR, Nixon A, Calderwood-Mays M, Gronwall R, Pendergast J. Comparison of staple and suture techniques for end-to-end anastomosis of the small colon in horses. Am J Vet Res 1988;49(9):1621–8.
  • [6] Malolepsza-Bazan A, Strutynska-Karpinska M. Evaluation of postoperative complications of colorectal surgery. Adv Clin Exp Med 2008;17(6):655–60.
  • [7] Oida T, Kawasaki A, Mimatsu K, Kano H, Kuboi Y, Fukino N, Kida K, Amano S. Sutureless compression anastomosis with a biofragmentable anastomosis ring. Hepato- Gastroenterology 2011;58(110-111):1445–9.
  • [8] Richards C, Campbell V, Ho C, Hayes J, Elliott T, Thompson- Fawcett M. Smoking is a major risk factor for anastomotic leak in patients undergoing low anterior resection. Colorectal Dis 2012;14(5):628–33.
  • [9] Rullier E, Laurent C, Garrelon J, Michel P, Saric J, Parneix M. Risk factors for anastomotic leakage after resection of rectal cancer. Br J Surg 1998;85(3):355–8.
  • [10] Walker KG, Bell SW, Rickard MJ, Mehanna D, Dent OF, Chapuis PH, et al. Anastomotic leakage is predictive of diminished survival after potentially curative resection for colorectal cancer. Ann Surg 2004;240(2):255–9.
  • [11] Harustiak T, Pazdro A, Snajdauf M, Stolz A, Lischke R. Anastomotic leak and stricture after hand-sewn versus linear-stapled intrathoracic oesophagogastric anastomosis: single-centre analysis of 415 oesophagectomies. Eur J Cardio-thoracic Surg 2015;49(6):1650–9.
  • [12] Durdey P, Bucknall T. Assessment of sutures for use in colonic surgery: an experimental study. J R Soc Med 1984;77 (6):472–7.
  • [13] Helmrath MA, VanderKolk WE, Can G, Erwin CR, Warner BW. Intestinal adaptation following massive small bowel resection in the mouse. J Am Coll Surg 1996;183(5):441–9.
  • [14] Högström H, Haglund U, Zederfeldt B. Suture technique and early breaking strength of intestinal anastomoses and laparotomy wounds. Acta Chir Scand 1985;151(5):441–3.
  • [15] Houdart R, Lavergne A, Galian A, Hautefeuille P. Anatomo- pathological evolution of single-layer end-to-end digestive anastomoses. A study of 210 colonic anastomoses in rats from the 2d to the 180th day. Gastroenterol Clin Biol 1983;7 (5):465–73.
  • [16] Jiborn H, Ahonen J, Zederfeldt B. Healing of experimental colonic anastomoses: II. Breaking strength of the colon after left colon resection and anastomosis. Am J Surg 1978;136 (5):595–9.
  • [17] Jiborn H, Ahonen J, Zederfeldt B. Healing of experimental colonic anastomoses: I. Bursting strength of the colon after left colon resection and anastomosis. Am J Surg 1978;136 (5):587–94.
  • [18] Jiborn H, Ahonen J, Zederfeldt B. Healing of experimental colonic anastomoses: iv. Effect of suture technique on collagen metabolism in the colonic wall. Am J Surg 1980;139 (3):406–13.
  • [19] Mosafer Khoorjestan S, Rouhi G, Toolabi K. Experimental investigations on intestinal anastomosis: a comparison between automatic and hand suturing techniques. J Mech Med Biol 2016;16(4):1650056.
  • [20] Mosafer Khoorjestan S, Rouhi G, Toolabi K. An investigation of the effects of suture patterns on mechanical strength of intestinal anastomosis: an experimental study. Biomedical Engineering/Biomedizinische Technik 2017;62(4):429–37.
  • [21] Shandall A, Lowndes R, Young H. Colonic anastomotic healing and oxygen tension. Br J Surg 1985;72(8):606–9.
  • [22] Mosafer Khoorjestan S, Rouhi G. An automatic suturing machine for intestinal anastomosis: advantages compared with hand-suturing technique. Surg Innov 2019;26(2):209–18.
  • [23] Slieker JC, Daams F, Mulder IM, Jeekel J, Lange JF. Systematic review of the technique of colorectal anastomosis. JAMA Surg 2013;148(2):190–201.
  • [24] Samartsev V, Kuchumov A, Gavrilov V. Sutures in abdominal surgery: biomechanical study and clinical application. Open Med 2014;9(6):849–59.
  • [25] Eickhoff R, Eickhoff SB, Katurman S, Klink CD, Heise D, Kroh A, Neumann UP, Binnebösel M. Influence of suture technique on anastomotic leakage rate—a retrospective analyses comparing interrupted—versus continuous— sutures. Int J Colorectal Dis 2019;34(1):55–61.
  • [26] Fakhr F. Uretheroplasty: comparison of uretheroplasty with vicryl and pds in peads. Prof Med J 2018;25(1):5–9.
  • [27] Mortensen NJ, Ashraf S. ACS surgery: principles and practice. Canada: Hamilton: BC Decker Inc; 2008 [chapter 29].
  • [28] Zarour AM, Maull KI, Tayyem R. Essentials of bowel anastomosis. US: CineMed Publishing; 2012 [chapter 5].
  • [29] Roberts JR, Hedges JR. Clinical procedures in emergency medicine. Elsevier Health Sciences; 2009.
  • [30] Li B, Logan BE. Bacterial adhesion to glass and metal- oxide surfaces. Colloids Surf B Biointerfaces 2004;36 (2):81–90.
  • [31] Egorov VI, Schastlivtsev IV, Prut EV, Baranov AO, Turusov RA. Mechanical properties of the human gastrointestinal tract. J Biomech 2002;35(10):1417–25.
  • [32] Greenwald D, Shumway S, Albear P, Gottlieb L. Mechanical comparison of 10 suture materials before and after in vivo incubation. J Surg Res 1994;56(4):372–7.
  • [33] Gu L, Kasavajhala ARM, Lang H, Hammel JM. Numerical and experimental investigation of vascular suture closure. Biomed Eng Lett 2012;2(1):46–51.
  • [34] Nowak Z. Constitutive modelling and parameter identification for rubber-like materials. Eng Trans 2008;56(2):117–57.
  • [35] Christensen MB, Oberg K, Wolchok JC. Tensile properties of the rectal and sigmoid colon: a comparative analysis of human and porcine tissue. SpringerPlus 2015;4(142).
  • [36] Fuller JK, Fuller JR. Surgical technology: principles and practice. Elsevier Health Sciences; 2012.
  • [37] Lagattolla N, Lattimer C, Wilson N. Key topics in general surgery. US: CRC Press; 2002.
  • [38] Thomas WEG, Thomas WE, Reed MW, Wyatt MG. Oxford textbook of fundamentals of surgery. Oxford University Press; 2016.
  • [39] Byrne M, Aly A. The surgical suture. Aesthet Surg J 2019;39 (Supplement_2):S67–72.
  • [40] Bustos-Fernández L. Colon: structure and function. Springer Science & Business Media; 2013.
  • [41] Lockhart-Mummery J. The technique of resection and anastomosis of the colon for tumour. Proc R Soc Med 1923;16(Surg_Sect):69–81.
  • [42] Carniel E, Gramigna V, Fontanella C, Frigo A, Stefanini C, Rubini A, et al. Characterization of the anisotropic mechanical behaviour of colonic tissues: experimental activity and constitutive formulation. Exp Physiol 2014;99 (5):759–71.