Use of Matlab Package for External Local Calibration of IR Camera with Microbolometric FPA Detector

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This work presents the method of improving the accuracy of temperature measurement results obtained by means of long-wave infrared camera equipped with focal plane array (FPA) detector. The typical accuracy of infrared cameras specified by their manufacturers amounts to ±2 K or ±2% of the measured value of temperature. Very often a better accuracy of the measurements is required, e.g. during the measurements of human body temperature. To improve the measurement accuracy an external local (in terms of temperature range) correction of obtained results on the basis of comparison measurement results of black body temperature and next with use of MATLAB package has been proposed.
Wydawca
Rocznik
Strony
337--340
Opis fizyczny
Bibliogr. 9 poz., rys., wykr., wzory
Twórcy
autor
  • Institute of Thermal Technology, Silesian University of Technology, 22 Konarskiego St., 44-100 Gliwice, Poland
autor
  • Institute of Thermal Technology, Silesian University of Technology, 22 Konarskiego St., 44-100 Gliwice, Poland
autor
  • Institute of Thermal Technology, Silesian University of Technology, 22 Konarskiego St., 44-100 Gliwice, Poland
Bibliografia
  • [1] Howell J. R., Siegel R., Mengüç M. P.: Thermal radiation heat transfer. CRC Press Taylor&Francis Group, New York 2011.
  • [2] Modest M. F.: Radiative heat transfer. McGraw-Hill, Inc., NY, 1993.
  • [3] Technical Documentation ThermaCAM SC2000, FLIR.
  • [4] Minkina W., Dudzik S.: Infrared Thermography - Errors and Uncertainties. Wiley & Sons, UK; 2009.
  • [5] Olbrycht R., Więcek B.: Correction of microbolometer detector temperature drift, MAM, vol. 55, No 11, pp. 890-893, 2009.
  • [6] Rainieri S., Pagliarini G.: Data processing technique applied to the calibration of a high performance FPA infrared camera, Infrared Physics & Technology, vol. 43, pp.345-351, 2002.
  • [7] Kruczek T.: Analysis of the influence of external conditions on thermovision measurement results. Proc. of 5-th Conf. TTP 2002, Ustroń (Poland), pp. 327-332, 2002, (in Polish).
  • [8] Kruczek T.: Conditions for the use of infrared camera diagnostics in energy auditing of the objects exposed to open air space at isothermal sky. Archives of Thermodynamics, vol. 36, No. 1, pp. 67-82, 2015.
  • [9] Kruczek T.: Use of infrared camera in energy diagnostics of the objects placed in open air space in particular at non-isothermal sky. Energy, vol. 91, pp. 35-47, 2015.
Uwagi
EN
The research has been supported by National Science Centre within OPUS scheme under contract UMO-2013/11/B/ST8/0026S and SONATA scheme under contract UMO-2014/15/D/ST8/2620.
PL
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę (zadania 2017).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-5c10ed0b-3e57-4dff-ad4a-d2f359166eef
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.