The influence of boundary conditions on the safety of steel trusses subjected to high temperatures

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Wpływ warunków brzegowych na bezpieczeństwo stalowych kratownic poddanych działaniu wysokich temperatur
Języki publikacji
EN PL
Abstrakty
EN
The study provides an analysis of three trusses that differed only with respect to support. All trusses were analysed for normal and accidental design cases, latter under fire load. A standard fire curve was adopted, and it was assumed that all the elements were heated from all sides. Using the MES3D program, temperature increase in bars, values of displacements and those of axial forces were determined for all structures in the successive minutes of the fire. The state of stress and displacement in the successive minutes of fire was discussed.
PL
Artykuł dotyczy analizy trzech kratownic, różniących się między sobą sposobem podparcia. Wszystkie kratownice zostały przeanalizowane w normalnej sytuacji projektowej oraz podczas pożaru. Zastosowano krzywą pożaru standardowego i założono, że wszystkie elementy są ogrzewane z każdej strony. W kolejnych minutach trwania pożaru obliczono wzrost temperatury w prętach kratownicy, przemieszczenia węzłów oraz siły osiowe. Do obliczeń wykorzystano program MES3D. Omówiono stan naprężeń i przemieszczeń w kolejnych minutach pożaru.
Rocznik
Strony
229--240
Opis fizyczny
Bibliogr. 13 poz., rys., tab.
Twórcy
autor
  • Kielce University of Technology
autor
  • Kielce University of Technology
autor
  • Kielce University of Technology
Bibliografia
  • [1] Biegus A., Fire damages and steel building roof repairs (in Polish), Proc. of XXVI Conf. „Awarie budowlane”, Międzyzdroje, 21-24 May 2013.
  • [2] Gierczak J., Kmita A., Wróblewski R., Smardz P., Steel structure failure in a production facility in Lubań as a result of the fire (in Polish), Proc. of XXVI Conf. „Awarie budowlane”, Międzyzdroje, 21-24 May 2013.
  • [3] Maślak M., Tkaczyk A., Assessment of steel bearing structure safety after a fire (in Polish), Proc. of XXV Conf. „Awarie budowlane”, Międzyzdroje, 24-27 May 2011.
  • [4] Franssen J.M., Kodur V., Zaharia R., Designing steel structures for fire safety, CRC Press, London 2009.
  • [5] Purkiss J.A., Li L.Y., Fire safety engineering design of structures, 3nd ed., CRC Press, Boca Raton, London-New York 2014.
  • [6] Li G., Wang P., Advanced analysis and design for fire safety of steel structures, Springer, 2013.
  • [7] Kubicka K., Radoń U., Comparison of steel trusses analysed with different types of fire curves, “Applied Mechanics and Materials” 2015, Vol. 797, pp. 108-114.
  • [8] Guo Q., Shi K., Jia Z., Jeffers A.E., Probabilistic Evaluation of Structural Fire Resistance. Special Issue: World Trade Center, “Fire Technology” 2013, 49, pp. 793-811.
  • [9] Kubicka K., Radoń U., Proposal for the assessment of steel truss reliability under fire condition, “Archives of Civil Engineering” 2015, Vol. 61, Issue 4, pp. 141-154.
  • [10] PN-EN 1993-1-1. Eurocode 3: Design of steel structures. Part 1-1: General rules and rules for buildings.
  • [11] PN-EN 1991-1-2. Eurocode 1: Actions on structures. Part 1-2: General actions: Action on structures exposed to fire.
  • [12] PN-EN 1993-1-2. Eurokod 3: Design of steel structures. Part 1-2: General rules: Structural fire design.
  • [13] Szaniec W., Zielińska K., Harmonic analysis of the wind-loaded bar dome at the satellite services centre in Psary, “Archives of Civil Engineering” 2016, Vol. 62, Issue 1, pp. 37-50.