Identyfikatory
Warianty tytułu
Wpływ matrycy wodnej na retencję farmaceutyków w wysokociśnieniowej filtracji membranowej
Języki publikacji
Abstrakty
High-pressure membrane processes, including nanofiltration and reverse osmosis, allow for the removal of a wide range of organic micropollutants (including pharmaceutical compounds) from water streams. Those processes also may be an effective method for in-depth treatment of water containing pharmaceutical compounds. The paper presents a comparison of retention of selected pharmaceuticals from the group of non-steroidal and anti-inflammatory drugs, ie ibuprofen and diclofenac and psychotropic drugs – carbamazepine, present in various aqueous matrices in the nanofiltration process. Deionized water based solutions as well as model and real wastewater effluents after biological treatment processes were subjected to the filtration process. The nanofiltration process was carried out in a cross-flow tubular membrane filtration system. Three polyamide membranes AFC30, AFC40 and AFC80 from PCI Membrane System Inc were used. It has been found, that the retention of pharmaceutical compounds increased with the membrane filtration time, regardless of the composition of the treated aqueous matrix. Moreover, the presence of inorganic compounds and high-molecular organic substances had a positive effect on the membrane separation process of micropollutants.
Wysokociśnieniowe procesy membranowe, do których zaliczamy nanofiltrację i odwróconą osmozę, pozwalają na oczyszczenie strumieni wodnych z szerokiej gamy mikrozanieczyszczeń organicznych. Mogą znaleźć również zastosowanie w doczyszczaniu wód pod kątem eliminacji związków farmaceutycznych. W pracy przedstawiono porównanie stopnia retencji wybranych farmaceutyków z grupy niesteroidowych leków przeciwbólowych i przeciwzapalnych, tj. ibuprofen i diklofenak oraz leków psychotropowych – karbamazepina, obecnych w różnych matrycach wodnych w procesie nanofiltracji. Oczyszczaniu poddano roztwory sporządzone na bazie wody zdejonizowanej oraz modelowy i rzeczywisty odpływ po biologicznym oczyszczaniu ścieków. Proces nanofiltracji prowadzono w układzie filtracji krzyżowej przy zastosowaniu rurowego modułu membranowego. Oceniono efektywność procesu przy wykorzystaniu trzech poliamidowych membrana, tj. AFC30, AFC40 i AFC80 firmy PCI Membrane System Inc. Określono, że wraz z czasem filtracji membranowej wzrasta stopień retencji badanych związków farmaceutycznych niezależnie od składu oczyszczanej matrycy wodnej. Ponadto stwierdzono, że obecność w roztworze związków nieorganicznych oraz wysokocząsteczkowych substancji organicznych wpływa korzystnie na proces membranowej separacji mikrozanieczyszczeń.
Czasopismo
Rocznik
Tom
Strony
469--479
Opis fizyczny
Bibliogr. 12 poz., wykr., tab.
Twórcy
autor
- Institute of Water and Wastewater Engineering, Silesian University of Technology, ul. Konarskiego 18, 44–100 Gliwice, Poland, phone: +48 32 237 16 98, fax: +48 32 237 10 47
autor
- Institute of Water and Wastewater Engineering, Silesian University of Technology, ul. Konarskiego 18, 44–100 Gliwice, Poland, phone: +48 32 237 16 98, fax: +48 32 237 10 47
autor
- Institute of Water and Wastewater Engineering, Silesian University of Technology, ul. Konarskiego 18, 44–100 Gliwice, Poland, phone: +48 32 237 16 98, fax: +48 32 237 10 47
Bibliografia
- [1] Aga DS. Fate of Pharmaceuticals in the Environment and in Water Treatment Systems. Boca Raton: CRC Press. Taylor Francis Group; 2008.
- [2] Directive 2013/39/EU of the European Parliament and of the Council of 12 August 2013 amending Directives 2000/60/EC and 2008/105/EC as regards priority substances in the field of water policy. Official J Europ Union. 2013;L 226;1-17. http://faolex.fao.org/docs/pdf/eur127344.pdf
- [3] Commission Implementing Decision (EU) 2015/495 of 20 march 2015 establishing a watch list of substances for Union-wide monitoring in the field of water policy pursuant to Directive 2008/105/EC of the European Parliament and of the Council. Official J Europ Union. 2015;78;40-42. http://faolex.fao.org/docs/pdf/eur142647.pdf
- [4] Feng L, van Hullebusch ED, Rodrigo MA, Esposito G, Oturan MA. Chem Eng J. 2013;228;944-964. DOI: 10.1016/j.cej.2013.05.061
- [5] Sin J-C, Lam S-M, Mohamed AR, Lee K-T, Int J Photoenergy. 2012;2012;1-23. DOI: 10.1155/2012/185159
- [6] Xu P, Drewes JE, Kim T-U, Bellona C, Amy G. J Membr Sci. 2006;279;156-175. DOI: 10.1016/j.memsci.2005.12.001
- [7] Radjenović J, Petrović M, Ventura F, Barceló D. Water Res. 2008;42;3601-3610. DOI:10.1016/j.watres.2008.05.020.
- [8] Vergili I. J Environ Manage. 2013;127;177-187 DOI:10.1016/j.jenvman.2013.04.036
- [9] Verliefde ARD, Cornelissen ER, Heijmana SGJ, Petrinic I, Luxbacher T , Amy GL, et al. J Membr Sci. 2009; 330; 90-103. DOI:10.1016/j.memsci.2008.12.039
- [10] Dolar D, Košutić K. Compre Anal Chem. 2013;62;319–344. DOI:10.1016/B978-0-444-62657-8.00010-0
- [11] Dolar D, Vuković A, Asperger D, Kosutić K. J Environ Sci (China). 2011;23;1299-1307. DOI: 10.1016/S1001-0742(10)60545-1
- [12] Bellona C, Drewes JE. J Membr Sci. 2005;249;227-234. DOI:10.1016/j.memsci.2004.09.041
Typ dokumentu
Bibliografia
Identyfikator YADDA