Fault diagnostics of transformer winding in time and frequency domain

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The paper presents basic overview of measuring methods and fault diagnostics on the power transformers and illustrating measurement on transformer winding using with methods of impact test and frequency response analysis (SFRA). Impact test and SFRA method are often used for analyzing of the insulation between coil threads or themselves of windings and for detection of the attenuated winding sections of transformers. There methods enable detecting early condition of the winding faults. In the paper is presented experimental measurement on distribution three-phase transformer 22/0.4 kV without operation by time and frequency domain by impact test and SFRA method. It was used comparison of measured curve for all phases using with mathematical statistical methods. It was found fault coil into primary winding of coil phase A.
Czasopismo
Rocznik
Strony
49--54
Opis fizyczny
Bibliogr. 14 poz., rys., tab.
Twórcy
  • Department of Measurement and Application Electrical Engineering, Faculty of Electrical Engineering and Information Technology, University of Žilina, Univerzitna 1, 010 26 Zilina, Slovakia
  • Department of Measurement and Application Electrical Engineering, Faculty of Electrical Engineering and Information Technology, University of Žilina, Univerzitna 1, 010 26 Zilina, Slovakia
Bibliografia
  • 1. Brandt M. Identification failure of 3 MVA furnace transformer., DEMISEE 2016, Papradno, SR. 2016:6-10.
  • 2. Arumugam S. Experimental investigation on terminal connection and system function pair during SFRA testing on three phase transformers. International Journal of Electrical Power & Energy Systems. 2014;58:101-110. https://doi.org/10.1016/j.ijepes.2014.01.003
  • 3. Koltunowicz TN, Zukowski P, Boiko O, Saad A, Fedotova JA, Fedotov AK, Larkin AV, Kasiuk J. AC hopping conductance in nanocomposite films with ferromagnetic alloy nanoparticles in a PbZrTiO3 matrix. Journal of Electronic Materials. 2015;44(7):2260-2268.
  • 4. Sedlák J, Brandt M, Seewald R. Influence of remanent magnetization on the diagnostic of distribution 25mva transformer by sfra method. ELEKTRO Proceedings 2012, IEEE Catalog Number: CFP1248S-CDR, 2012:465-468.
  • 5. Bharat Heavy Electricals Limited Bhopal. Transformers 2nd edition. New Dehli: McGraw Hill Education Private Limited. 2003.
  • 6. Glowacz, A. Acoustic fault analysis of three commutator motors. Mechanical Systems and Signal Processing. 2019;133:106226. https://doi.org/10.1016/j.ymssp.2019.07.007
  • 7. Cimbala R, Kurimsky J, Kolcunova I. Determination of thermal ageing influence on rotating machine insulation system using dielectric spectroscopy. Przegląd Elektrotechniczny. 2011;87(8):176-179.
  • 8. Simko M, Chupac M. Non-destructive method of measurement of radio transmitters antenna systems. Elektronika ir elektrotechnika = Electronics and electrical engineering. 2011;107: 33-36.
  • 9. Glowacz A. recognition of acoustic signals of commutator motors. Applied Sciences-BASEL, 2018;8(12):2630. https://doi.org/10.3390/app8122630
  • 10. Gutten M, Korenciak D, Kucera M, Janura R, Glowacz A, Kantoch E. Frequency and time fault diagnosis methods of power transformers. Measurement Science Review, 2018;18 (4): 162-167. https://doi.org/10.1515/msr-2018-0023
  • 11. Ballon Instrument: Manual of generator PSG 204 A.
  • 12. Saha TK, Yao TZ. Experience with return voltage measurements for assessing insulation conditions. IEEE Transactions On Power Delivery. 2003; 18(1):128-135.
  • 13. Brandt M. Experimental measurement and analysis of frequency responses SFRA for rotating electrical machines. Elektroenergetika Stará Lesná, Slovak Republic. 2017:284-288.
  • 14. Megger: Manual of instrument FRAX 150.