Nowa metoda określania efektywności działania związków zmiennofazowych (PCMs) na przykładzie badań z wykorzystaniem manekina termicznego

Autorzy
Identyfikatory
Warianty tytułu
EN
A new method of measuring the effectiveness of the phase change materials (PCMs) in the studies with a thermal manikin
Języki publikacji
PL
Abstrakty
EN
Until now, there was no a uniform methodology for research the effectiveness of the phase change materials (PCMs) used e.g. in cooling vests. For this reason the Laboratory of Thermal Load at CIOP-PIB has joined in the attempts in research attempting to systematize knowledge in this field. The article presents a new method allowing measuring the effectiveness of the phase change materials (PCMs).
Słowa kluczowe
Rocznik
Tom
Strony
23--25
Opis fizyczny
Bibliogr. 8 poz., rys.
Twórcy
  • Centralny Instytut Ochrony Pracy - Państwowy Instytut Badawczy
Bibliografia
  • 1. Zwolińska M., Bogdan A.: Związki zmiennofazowe w zastosowaniach techniczno-użytkowych i ergonomicznych. Bezpieczeństwo Pracy, Nauka i Praktyka. 2012, 4, 22 - 25.
  • 2. http://www.outlast.com/ z dnia 26.08.2013 r.
  • 3. Nishihara N. et al.: A cooling vest for working comfortably in a moderately hot environment. Journal of physiological anthropology and applied human science. 2001, 75 - 82.
  • 4. Pasue B.: New cooling undergarment for protective garment system. 3rd ECPC, 2006.
  • 5. Smolander J., Kuklane K., Gavhed D., Nilsson H., Holmer I.: Effectiveness of a Light-weight ice-vest for body cooling while wearing fire fighter's protective clothing in the heat. International Journal of Occupational Safety and Ergonomics. 2004, 10, 2, 111 - 117.
  • 6. Bendkowska W., Klonowska M., Kopias K., Bogdan A.: Thermal manikin Evaluation of PCM Cooling Vests. Fibres & Textiles in Eastern Europe. 2010, 18(1/78), 70 - 74.
  • 7. Gao Ch., Kuklane K., Holmer I.: The heating effect of phase Cheng material (PCM) vests on a thermal manikin in a subzero environment. 7th International Thermal Manikin and Modeling - University of Coimbra. September 2008.
  • 8. ASTM F2371-10 Standard Test Method for Measuring the Heat Removal Rate of Personal Cooling System Using a Sweating Heated Manikin