Selected aspects of the application of the hybrid circulatory system in the analysis of heart insufficiency

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
There are many causes of heart failure, one of them being valvular heart disease. In this case, the stage and type of the disease can significantly affect the hemodynamic parameters of the left ventricle of the heart. In turn, these parameters can significantly influence the mode, type and strategy of clinical treatment. The aim of the study was to analyze and map the hydrodynamic conditions of the heart using a hybrid-digital model of the circulatory system. Methods: The tests performed using the circulatory system model allowed for the simulation of the failure of both heart’s left ventricle and a set of arteries in the systemic circulation. Furthermore, the changes in hemodynamic parameters for valvular anomalies at various heartbeats were obtained. Results: The results suggested that a higher heartbeat should be sustained in such cases of complex mitral-aortic anomalies in the clinical practice. When observing low aortic pressures, heartbeat should be increased to compensate for the valvular insufficiencies. Conclusions: Extending the already conducted research could result in constituting a wide database for clinicians who are treating the insufficiency of the left ventricle of the heart. Moreover, the information included in this paper may be used for a comparison of the clinical anomalies, which facilitates a correct diagnosis. The test-stand used in the research can be applied to predict the anomalies of the circulation system for a quick and precise analysis of a clinical anomaly of a patient without physical presence.
Rocznik
Strony
153--161
Opis fizyczny
Bibliogr. 40 poz., rys., tab., wykr.
Twórcy
  • Faculty of Mechanical Engineering, Cracow University of Technology, Kraków, Poland.
  • The Interuniversity Center for The New Techniques and Medical Technologies, Kraków, Poland.
  • The Interuniversity Center for The New Techniques and Medical Technologies, Kraków, Poland.
  • Faculty of Mechanical Engineering, Cracow University of Technology, Kraków, Poland.
Bibliografia
  • [1] ABRAHAM W.T., ADAMSON P.B., BOURGE R.C., AARON M.F., COSTANZO M.R., STEVENSON L.W., STRICKLAND W., NEELAGARU S., RAVAL N., KRUEGER S., WEINER S., SHAVELLE D., JEFFRIES B., YADAV J.S., Wireless pulmonary artery haemodynamic monitoring in chronic heart failure: a randomised controlled trial, Lancet, 2011, 377 (9766), 658–666, DOI: 10.1016/S0140-6736(11)60101-3.
  • [2] BHATTACHARYA-GHOSH B., SCHIEVANO S., DÍAZ-ZUCCARINI V., A multi-physics and multi-scale lumped parameter model of cardiac contraction of the left ventricle: A conceptual model from the protein to the organ scale, Comput. Biol. Med., 2012, 42 (10), 982–992, DOI: 10.1016/j.compbiomed.2012.07.010.
  • [3] BONOW R.O., CASTELVECCHIO S., PANZA J.A., BERMAN D.S., VELAZQUEZ E.J., MICHLER R.E., SHE L., HOLLY T.A., DESVIGNE-NICKENS P., KOSEVIC D., RAJDA M., CHRZANOWSKI L., DEJA M., LEE K.L., WHITE H., OH J.K., DOENST T., HILL J.A., ROULEAU J.L., MENICANTI L., Severity of Remodeling, Myocardial Viability, and Survival in Ischemic LV Dysfunction After Surgical Revascularization, JACC Cardiovasc. Imaging, 2015, 8 (10), 1121–1129, DOI: 10.1016/J.JCMG.2015.03.013.
  • [4] CAFORIO A.L.P., CALABRESE F., ANGELINI A., TONA F., VINCI A., BOTTARO S., RAMONDO A., CARTURAN E., ILICETO S., THIENE G., DALIENTO L., A prospective study of biopsy-proven myocarditis: prognostic relevance of clinical and aetiopathogenetic features at diagnosis, Eur. Heart J., 2007, 28 (11), 1326–1333, DOI: 10.1093/EURHEARTJ/EHM076.
  • [5] COOPER L.T., BAUGHMAN K.L., FELDMAN A.M., FRUSTACI A., JESSUP M., KUHL U., LEVINE G.N., NARULA J., STARLING R.C., TOWBIN J., VIRMANI R., The role of endomyocardial biopsy in the management of cardiovascular disease: a scientific statement from the American Heart Association, the American College of Cardiology, and the European Society of Cardiology. Endorsed by the Heart Failure Society of America and the Heart Failure Association of the European Society of Cardiology, J. Am. Coll. Cardiol., 2007, 50 (19), 1914–1931, DOI: 10.1016/J.JACC.2007.09.008.
  • [6] CORRÀ U., PIEPOLI M.F., ADAMOPOULOS S., AGOSTONI P., COATS A.J.S., CONRAADS V., LAMBRINOU E., PIESKE B., PIOTROWICZ E., SCHMID J.P., SEFEROVÍC P.M., ANKER S.D., FILIPPATOS G., PONIKOWSKI P.P., Cardiopulmonary exercise testing in systolic heart failure in 2014: the evolving prognostic role: a position paper from the committee on exercise physiology and training of the heart failure association of the ESC, Eur. J. Heart Fail., 2014, 16 (9), 929–941, DOI: 10.1002/EJHF.156.
  • [7] DONAL E., LUND L.H., OGER E., REYNAUD A., SCHNELL F., PERSSON H., DROUET E., LINDE C., DAUBERT C., Value of exercise echocardiography in heart failure with preserved ejection fraction: a substudy from the KaRen study, Eur. Hear Journal Cardiovasc Imaging, 2016, 17 (1), 106–113, DOI: 10.1093/EHJCI/JEV144.
  • [8] FERNANDEZ DE CANETE J., SAZ-OROZCO P. DEL, MORENO-BOZA D., DURAN-VENEGAS E., Object-oriented modeling and simulation of the closed loop cardiovascular system by using SIMSCAPE, Comput. Biol. Med., 2013, 43 (4), 323–333, DOI: 10.1016/j.compbiomed.2013.01.007.
  • [9] FILIPPATOS G., KHAN S.S., AMBROSY A.P., CLELAND J.G.F., COLLINS S.P., LAM C.S.P., ANGERMANN C.E., ERTL G., DAHLSTRÖM U., HU D., DICKSTEIN K., PERRONE S. V., GHADANFAR M., BERMANN G., NOE A., SCHWEIZER A., MAIER T., GHEORGHIADE M., International REgistry to assess medical Practice with lOngitudinal obseRvation for Treatment of Heart Failure (REPORT-HF): Rationale for and design of a global registry, Eur. J. Heart Fail., 2015, 17 (5), 527–533, DOI: 10.1002/ejhf.262.
  • [10] FRIEDRICH M.G., SECHTEM U., SCHULZ-MENGER J., HOLMVANG G., ALAKIJA P., COOPER L.T., WHITE J.A., ABDEL- -ATY H., GUTBERLET M., PRASAD S., ALETRAS A., LAISSY J.P., PATERSON I., FILIPCHUK N.G., KUMAR A., PAUSCHINGER M., LIU P., Cardiovascular magnetic resonance in myocarditis: A JACC White Paper, J. Am. Coll. Cardiol., 2009, 53 (17), 1475–1487, DOI: 10.1016/J.JACC.2009.02.007.
  • [11] FUKUTA H., GOTO T., WAKAMI K., OHTE N., Effects of drug and exercise intervention on functional capacity and quality of life in heart failure with preserved ejection fraction: A meta-analysis of randomized controlled trials, Eur. J. Prev. Cardiol., 2016, 23 (1), 78–85, DOI: 10.1177/2047487314564729.
  • [12] GABRYŚ E., RYBACZUK M., KĘDZIA A., Blood flow simulation through fractal models of circulatory system, Chaos, Solitons and Fractals, 2006, 27 (1), 1–7, DOI: 10.1016/j.chaos.2005.02.009.
  • [13] GARBI M., MCDONAGH T., COSYNS B., BUCCIARELLI-DUCCI C., EDVARDSEN T., KITSIOU A., NIEMAN K., LANCELLOTTI P., Appropriateness criteria for cardiovascular imaging use in heart failure: report of literature review, Eur. Hear Journal Cardiovasc Imaging, 2015, 16 (2), 147–153, DOI: 10.1093/EHJCI/JEU299.
  • [14] GARNIER F., EICHER J.C., JAZAYERI S., BERTAUX G., BOUCHOT O., AHO L.S., WOLF J.E., LAURENT G., Usefulness and limitations of contractile reserve evaluation in patients with low-flow, low-gradient aortic stenosis eligible for cardiac resynchronization therapy, Eur. J. Heart Fail., 2014, 16 (6), 648–654, DOI: 10.1002/EJHF.78.
  • [15] JOLICOEUR E.M., DUNNING A., CASTELVECCHIO S., DABROWSKI R., WACLAWIW M.A., PETRIE M.C., STEWART R., JHUND P.S., DESVIGNE-NICKENS P., PANZA J.A., BONOW R.O., SUN B., SAN T.R., AL-KHALIDI H.R., ROULEAU J.L., VELAZQUEZ E.J., CLELAND J.G.F., Importance of angina in patients with coronary disease, heart failure, and left tricular systolic dysfunction: insights from STICH, J. Am. Coll. Cardiol., 2015, 66 (19), 2092–2100, DOI: 10.1016/J.JACC.2015.08.882.
  • [16] KELLY J.P., MENTZ R.J., MEBAZAA A., VOORS A.A., BUTLER J., ROESSIG L., FIUZAT M., ZANNAD F., PITT B., O’CONNOR C.M., LAM C.S.P., Patient selection in heart failure with preserved ejection fraction clinical trials, J. Am. Coll. Cardiol., 2015, 65 (16), 1668–1682, DOI: 10.1016/j.jacc.2015.03.043.
  • [17] KOBIELARZ M., Effect of collagen fibre and elastic lamella content on the mechanical behaviour of abdominal aortic aneurysms, Acta Bioeng. Biomech., 2020, 22 (3), 1–21, DOI: 10.37190/ABB-01580-2020-02.
  • [18] KOPERNIK M., DYRDA K., KURTYKA P., MAJOR R., Discrete phase model of blood flow in a roughness microchannel simulating the formation of pseudointima, Acta Bioeng. Biomech., 2022, 24 (1), DOI: 10.37190/ABB-01989-2021-02.
  • [19] KOTECHA D., HOLMES J., KRUM H., ALTMAN D.G., MANZANO L., CLELAND J.G.F., LIP G.Y.H., COATS A.J.S., ANDERSSON B., KIRCHHOF P., VON LUEDER T.G., WEDEL H., ROSANO G., SHIBATA M.C., RIGBY A., FLATHER M.D., Efficacy of β blockers in patients with heart failure plus atrial fibrillation: an individual- patient data meta-analysis, Lancet (London, England), 2014, 384 (9961), 2235–2243, DOI: 10.1016/S0140-6736(14)61373-8.
  • [20] KOZUŃ M., KACZOROWSKI M., HAŁOŃ A., The Layer-specific Biomechanical Properties of Dissecting Ascending Aortic Aneurysm (Stanford type A of dissection), Acta Bioeng. Biomech., 2022, 24 (2), DOI: 10.37190/ABB-02020-2022-01.
  • [21] KOZUŃ M., PŁONEK T., JASIŃSKI M., FILIPIAK J., Effect of dissection on the mechanical properties of human ascending aorta and human ascending aorta aneurysm, Acta Bioeng. Biomech., 2019, 21 (2), 127–134, DOI: 10.5277/ABB-01376-2019-01.
  • [22] LANG R.M., BADANO L.P., MOR-AVI V., AFILALO J., ARMSTRONG A., ERNANDE L., FLACHSKAMPF F.A., FOSTER E., GOLDSTEIN S.A., KUZNETSOVA T., LANCELLOTTI P., MURARU D., PICARD M.H., RIETZSCHEL E.R., RUDSKI L., SPENCER K.T., TSANG W., VOIGT J.U., Recommendations for cardiac chamber quantification by echocardiography in adults: An update from the American society of echocardiography and the European association of cardiovascular imaging, Eur. Heart J. Cardiovasc. Imaging, 2015, 16 (3), 233–271, DOI: 10.1093/ehjci/jev014.
  • [23] LI B., WANG H., LI G., LIU J., ZHANG Z., GU K., YANG H., QIAO A., DU J., LIU Y., A patient-specific modelling method of blood circulatory system for the numerical simulation of enhanced external counterpulsation, J. Biomech., 2020, 111, 110002, DOI: 10.1016/j.jbiomech.2020.110002.
  • [24] MISGELD B.J.E., RÜSCHEN D., SCHWANDTNER S., HEINKE S., WALTER M., LEONHARDT S., Robust decentralised control of a hydrodynamic human circulatory system simulator, Biomed. Signal Process Control, 2015, 20, 35–44, DOI: 10.1016/j.bspc.2015.04.004.
  • [25] MYERS L.J., CAPPER W.L., A transmission line model of the human foetal circulatory system, Med. Eng. Phys., 2002, 24 (4), 285–294, DOI: 10.1016/S1350-4533(02)00019-X.
  • [26] NG B.C., SALAMONSEN R.F., GREGORY S.D., STEVENS M.C., WU Y., MANSOURI M., LOVELL N.H., LIM E., Application of multiobjective neural predictive control to biventricular assistance using dual rotary blood pumps, Biomed. Signal Process Control, 2018, 39, 81–93, DOI: 10.1016/j.bspc.2017.07.028.
  • [27] PETROU A., GRANEGGER M., MEBOLDT M., DANERS M.S., A versatile hybrid mock circulation for hydraulic investigations of active and passive cardiovascular implants, ASAIO J, 2019, 65 (5), 495–502, DOI: 10.1097/MAT.0000000000000851.
  • [28] PORPHIRIEV A.O., PUGOVKIN A.A., SELISHCHEV S.V., TELYSHEV D.V., Development of artificial ventricles for modeling the cardiovascular system, Biomed. Eng. (NY), 2016, 49 (6), 331–334, DOI: 10.1007/s10527-016-9560-z.
  • [29] PUGOVKIN A.A., MARKOV A.G., SELISHCHEV S.V., KORN L., WALTER M., LEONHARDT S., BOCKERIA L.A., BOCKERIA O.L., TELYSHEV D.V., Advances in Hemodynamic Analysis in Cardiovascular Diseases Investigation of Energetic Characteristics of Adult and Pediatric Sputnik Left Ventricular Assist Devices during Mock Circulation Support, Cardiol. Res. Pract., 2019, 4593174, DOI: 10.1155/2019/4593174.
  • [30] RAHIMI K., BENNETT D., CONRAD N., WILLIAMS T.M., BASU J., DWIGHT J., WOODWARD M., PATEL A., MCMURRAY J., MACMAHON S., Risk prediction in patients with heart failure: a systematic review and analysis, JACC Heart Fail., 2014, 2 (5), 440–446, DOI: 10.1016/J.JCHF.2014.04.008.
  • [31] VAN RIET E.E.S., HOES A.W., WAGENAAR K.P., LIMBURG A., LANDMAN M.A.J., RUTTEN F.H., Epidemiology of heart failure: the prevalence of heart failure and ventricular dysfunction in older adults over time. A systematic review, Eur. J. Heart Fail., 2016, 18 (3), 242–252, DOI: 10.1002/EJHF.483.
  • [32] RUAN W., CLARK M.E., ZHAO M., CURCIO A., Global solution to a hyperbolic problem arising in the modeling of blood flow in circulatory systems, J. Math. Anal. Appl., 2007, 331 (2), 1068–1092, DOI: 10.1016/j.jmaa.2006.09.034.
  • [33] RUMIAN S., MILEWSKI G., KOPACZ M., ZAMARLIK S., The possibility of the hydrodynamic evaluation of bio-pumps with the use of a hybrid-digital model of the circulatory system, Meas. J. Int. Meas. Confed., 2016, 80, 281–287, DOI: 10.1016/j.measurement.2015.11.038.
  • [34] RÜSCHEN D., RIMKE M., GESENHUES J., LEONHARDT S., WALTER M., Online cardiac output estimation during transvalvular left ventricular assistance, Comput. Methods Programs Biomed., 2019, 171, 87–97, DOI: 10.1016/j.cmpb.2016.08.020.
  • [35] SIMAKOV S., TIMOFEEV A., GAMILOV T., KOPYLOV P., TELYSHEV D., VASSILEVSKI Y., Analysis of operating modes for left ventricle assist devices via integrated models of blood circulation, Mathematics, 2020, 8 (8), 1–18, DOI: 10.3390/MATH8081331.
  • [36] SWEDBERG K., KOMAJDA M., BÖHM M., BORER J., ROBERTSON M., TAVAZZI L., FORD I., Effects on outcomes of heart rate reduction by ivabradine in patients with congestive heart failure: is there an influence of beta-blocker dose?: findings from the SHIFT (Systolic Heart failure treatment with the I(f) inhibitor ivabradine Trial) study, J. Am. Coll. Cardiol., 2012, 59 (22), 1938–1945, DOI: 10.1016/J.JACC.2012.01.020.
  • [37] TELYSHEV D., PUGOVKIN A., SELISHCHEV S., RUSCHEN D., LEONHARDT S., Hybrid mock circulatory loop for training and study purposes, Proc. – 2018 Ural Symp. Biomed. Eng. Radioelectron Inf. Technol. USBEREIT, 2018, 29–32, DOI: 10.1109/USBEREIT.2018.8384542.
  • [38] TOMASZEWSKI M., SYBILSKI K., MAŁACHOWSKI J., WOLAŃSKI W., BUSZMAN P.P., Numerical and experimental analysis of balloon angioplasty impact on flow hemodynamics improvement, Acta Bioeng. Biomech., 2020, 22 (3), 169–183, DOI: 10.37190/ABB-01660-2020-03.
  • [39] ZAMORANO J.L., ANASTASAKIS A., BORGER M.A., BORGGREFE M., CECCHI F., CHARRON P., HAGEGE A.A., LAFONT A., LIMONGELLI G., MAHRHOLDT H., MCKENNA W.J., MOGENSEN J., NIHOYANNOPOULOS P., NISTRI S., PIEPE P.G., PIESKE B., RAPEZZI C., RUTTEN F.H., TILLMANNS C., WATKINS H., O’MAHONY C., ACHENBACH S., BAUMGARTNER H., BAX J.J., BUENO H., DEAN V., DEATON C., EROL Ç., FAGARD R., FERRARI R., HASDAI D., HOES A.W., KIRCHHOF P., KNUUTI J., KOLH P., LANCELLOTTI P., LINHART A., PIEPOLI M.F., PONIKOWSKI P., SIRNES P.A., TAMARGO J.L., TENDERA M., TORBICKI A., WIJNS W., WINDECKER S., ALFONSO F., BASSO C., CARDIM N.M., GIMENO J.R., HEYMANS S., HOLM P.J., KEREN A., LIONIS C., MUNERETTO C., PRIORI S., SALVADOR M.J., WOLPERT C., 2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy: the Task Force for the Diagnosis and Management of Hypertrophic Cardiomyopathy of the European Society of Cardiology (ESC), Eur. Heart J., 2014, 35 (39), 2733–2779, DOI: 10.1093/EURHEARTJ/EHU284.
  • [40] ZIELIŃSKI K., DAROWSKI M., KOZARSKI M., FERRARI G., The need for hybrid modeling in analysis of cardiovascular and respiratory support, Int. J. Artif. Organs, 2016, 39 (6), 265–271, DOI: 10.5301/ijao.5000513.