Gaseous emissions during agricultural biomass combustion in a 50 kw moving step grate boiler

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Results of the study examining carbon monoxide and nitric oxide concentrations while burning different types of agricultural biomass: coffee husk pellets alone or in combination with wheat straw pellets and cherry stones, sewage sludge pellets, corn stover briquettes and a mixture of rye straw briquettes and miscanthus briquettes were presented. The combustion was performed in a 50 kW boiler type Biowarmer with a cast-iron moving step grate. The temperature in the combustion chamber did not exceed 800 ◦C. For all biomass types, only brittle slag was generated in the furnace, which was easily broken by a reciprocating movement of the grate. Carbon monoxide concentration in the flue gas except for the case of sewage sludge pellet firing did not exceed the permitted value of 3000 mg/m3 and nitric oxide concentration 515 mg/m3, both presented for 10% O2 concentration in the flue gas based in dry gas. Hydrocarbon concentrations for all test runs were close to zero.
Rocznik
Strony
197--–208
Opis fizyczny
Bibliogr. 30 poz., rys.
Twórcy
  • Poznan University of Technology, Institute of Environmental Engineering, Division of Heating, Air Conditioning and Air Protection, Berdychowo 4, 60-965 Poznań, Poland
autor
  • Poznan University of Technology, Institute of Environmental Engineering, Division of Heating, Air Conditioning and Air Protection, Berdychowo 4, 60-965 Poznań, Poland
Bibliografia
  • 1. Cichewicz kotły c.o., 2015. Dokumentacja techniczno-ruchowa Instrukcja monta˙zu, obsługi i konserwacji. Available at: www.cichewicz.pl/pliki-do-pobrania.
  • 2. Cichy W., 2013. Materiały lignocelulozowe jako alternatywne ´zródło biopaliw stałych. Wydawnictwo Instytutu Technologii Drewna, Pozna´n.
  • 3. Cioabla E.A., Pop N., Colinoiu D.G., Trif-Tordai G., 2015. An experimental approach to the chemical properties and ash melting behavior in agricultural biomass. J. Therm. Anal. Calorim., 121, 421–427. DOI: 10.1007/s10973- 015-4710-1.
  • 4. Dell’Antonia D., Gubiani R., Pergher G., 2011. Comparative research of no-food sereals combustion in small heating appliances. 19th European Biomass Conference and Exhibitions. 6–10 June 2011, Berlin.
  • 5. Garcia–Cuevas M.T., Suero S.R., Nogales Delgado S., Montero Puertas I., Arranz Baria J.I., Rojas Moreno C.V., 2011. Effectiveness of blending process as a method for modifying the thermal behaviour and emission of olive and grape pomace during combustion. 19th European Biomass conference and Exhibitions, 6–10 June 2011, Berlin.
  • 6. Gible C., Ohman M., Lindstrom E., Bostrom D., Backman R., Samuelsson R., Burvall J., 2008. Slagging characteristic during residential combustion of biomass pellets. Energy Fuels, 22, 3536–3543. DOI: 10.1021/ef8000087x.
  • 7. Hardy T., Musialik-Piotrowska A., Ciołek J., Mo´scicki K., Kordylewski W., 2012. Negative effects of biomass combustion and co-combustion in boilers. Env. Prot. Eng., 1, 25–33.
  • 8. Hartge E.U., Ogada T., Saenger M., Siagi Z., Werther J., 2000. Combustion of agricultural residues. Prog. Energy Combust. Sci., 26, 1–27. DOI: 10.1016/S0360-1285(99)00005-2.
  • 9. Hartmann H., Reisinger K., Turowski P., Rossmann P., 2013. Handbuch Bioenergie-Kleinanlagen, Bundesministerium für Ernährung, Landwirtschaft und Verbraucherschutz. Fachagentur Nachwachsende Rohrstoffe e.v. (FNR), Gulzow-Pruzen.
  • 10. Juszczak M., Lossy K., 2012. Pollutant emission from a heat station supplied with agriculture biomass and wood pellet mixture. Chem. Process Eng., 33, 231–242. DOI: 10.2478/v10176-012-00203.
  • 11. Juszczak M., 2014.Concentration of carbon monoxide and nitrogen oxides from a 25 kW boiler supplied periodically. Chem. Process Eng., 35, 163–172. DOI: 10.2478/cpe-2014-0012.
  • 12. Kubica K., Jewiarz M., Kubica R., Szl˛ek A., 2016. Straw combustion: Pilot and laboratory studies on straw fired grate boiler. Energy Fuels, 30, 4405–4410. DOI: 10.1021/acs.energyfuels.5b02693.
  • 13. Marutzky R., Moderne Feuerungstechnik zur energetischenVerwertung von Holz und Holzabfallen, Springer-VDIVerlag GmbH&Co.K.G, Dusseldorf, 1997.
  • 14. Mediavilla I., Fernandez M.J., Esteban L.S., 2009. Optimization of pelletisation and combustion in a boiler of 17.5 kWth for vine shoots and industrial cork residue. Fuel Process. Technol., 90, 621–628. DOI: 10.1016/j.fuproc.2008.12.009.
  • 15. Mediavilla I., Borjabad E., Ramos R., Fernandez M.J., Carrasco J.E., 2011. Combustion behaviour of oat and triticale straws in comparison with wheat straw. 19th European Biomass Conference and Exhibition, 6–10 June 2011, Berlin.
  • 16. Mroczek K., Kalisz S., Pronobis M., Sołtys J., 2011. The effect of halloysite additive on operation of boilers firing agricultural biomass. Fuel Process. Technol., 92, 845–855. DOI: 10.1016/j.fuproc.2010.11.020.
  • 17. Pronobis M., 2005. Evaluation of the influence of biomass co-combustion on boiler furnace slagging by means of fusibility correlations. Biomass Bioenergy, 28, 375–383. DOI: 10.1016/j.biombioe.2004.11.003.
  • 18. Schonnenbeck C., Trouve G., Valente M., Garra P., Brilhac J.F., 2016. Combustion tests of grape marc in a multifuel domestic boiler. Fuel, 180, 324–331. DOI: 10.1016/j.fuel.2016.04.034.
  • 19. Vassiliev S.V., Baxter D.,Andersen L.K.,Vassileva C.G., 2013a. An overview of the composition and application of biomass ash. Part 1. Phase-mineral and chemical composition and classification. Fuel, 105, 40–76. DOI: 10.1016/j.fuel.2012.09.041.
  • 20. Vassiliev S.V., Baxter D., Andersen L.K., Vassileva C.G., 2013b. An overview of the composition and application of biomass ash. Part 2. Potential utilisation, technological and ecological advantages and challenges. Fuel, 105, 19–39. DOI: 10.1016/j.fuel.2012.10.001.
  • 21. Verma V.K., Brams S., Ruyck I., 2009. Small biomass heating systems: Standards, quality, labeling and market driving factors-An EU outlook. Biomass Bioenergy, 33, 1393–1402. DOI: 10.1016/j.biombioe.2009.06.002.
  • 22. Verma V.K., Bram S., Delattin F., De Ruyck J., 2013. Real life performance of domestic pellet boiler technologies as a function of operational loads: A case study of Belgium. Appl. Energy, 101, 357–362. DOI: 10.1016/j.apenergy.2012.02.017.
  • 23. Verma V.K., Bram S., Gautier G., 2011. Performance of domestic pellet boiler as a function of operational loads: Part-2. Biomass Bioenergy, 35, 272–279. DOI: 10.1016/j.biombioe.2010.08.043.
  • 24. Verma V.K., Bram S., Delattin F., Laha P., Vandendael I., Hubin A., De Ruyck J., 2012. Agro-pellets for domestic heating Boilers: Standard laboratory and real life performance. Appl. Energy, 90, 17–23. DOI: 10.1016/j.apenergy.2010.12.079.
  • 25. Wopienka E., Carvalho L., Ohman M., Schwabl M., Haslinger W., 2011. Evaluation of ash melting behaviour of solid biomass based on fuel analyses. 19th European Biomass Conference and Exhibition, 6–10 June 2011, Berlin.
  • 26. Yanqing N., Houzhang T., Shi’en H., 2016. Ash-related issues during biomass combustion: Alkali-induced slagging melt-induced slagging(ash fusion), agglomeration, corrosion, ash utilization, and related countermeasures. Prog. Energy Combust. Sci., 52, 1–61. DOI: 10.1016/j.pecs.2015.09.003.
  • 27. EN 14961-1, 2010. Solid biofuels-Fuel specification and classes – Part 1: General requirements.
  • 28. PN-EN 14961-1, 2010. Biopaliwa stałe. Specyfikacja paliw i klasy. Cz˛e´s´c 1: Wymagania ogólne.
  • 29. PN-81/G-04513, 1981. Paliwa stałe. Oznaczanie ciepła spalania i obliczanie warto´sci opałowej.
  • 30. PN-EN 303-5:2012. Kotły grzewcze – Cz˛e´s´c 5: Kotły grzewcze na paliwa stałe z r˛ecznym i automatycznym zasypem paliwa o mocy nominalnej do 500 kW – Terminologia, wymagania, badania i oznakowanie.