Heat load determination of boiler furnace chamber

Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The aim of the furnace chamber calculation is to determine the heat flux distribution transferred to water-walls tubes versus a furnace chamber height and the exhaust gas temperature at the furnace chamber outlet. In this paper a new construction of heat flux tubes for determining heat flux absorbed by membrane water-walls is presented. Flux tubes mounted at different levels work at similar conditions as water-walls tubes. The methodology of calculations of boilers furnace chambers using zone methods is presented. The results of calculations of the steam capacity 210 ×103 kg/h boiler furnace chamber using zone method are compared to the results obtained from measurement. The results of thermal load and gases temperature measurements along the combustion chamber height of the supercritical boiler will be compared with the results of computations.
Słowa kluczowe
Rocznik
Strony
75--88
Opis fizyczny
Bibliogr. 12 poz., rys., tab.
Twórcy
autor
  • Cracow University of Technology Institute of Thermal Power Engineering, Warszawska 24, 31-155 Cracow, Poland
Bibliografia
  • [1] Lehmann H.: Dampferzeugerpraxis. Grundlagen und Betrieb, Resch Verlag, Gräfelfing/München 1988.
  • [2] Taler J.: A method of determining local heat flux in boiler furnace, Int. J. Heat Mass Transfer, Vol.35, No. 6, 1992, 1625-1634.
  • [3] Taler J.: Messung der Wärmebelastung der gasdicht verschweiβten Verdampfer-Rohrwände in Dampferzeugern, VGB Kraftwerkstechnik, 70 (1990), 664-650.
  • [4] Węglowski B., 1995. Identification of thermal conditions of operation of the boiler furnace chamber walls (in Polish), Publishing House of Cracow University of Technology, No 76, Kraków.
  • [5] Łopata S.: Détermination du flux de chaleur instationnaire sur les surfaces cylindriques, Int.J.Heat Mass Transfer, Vol. 33, No. 2, (1990) pp. 349-357.
  • [6] Łopata S., Grądziel S., Gargula M., 2007. Instruments for monitoring the operation conditions in the boiler furnace chambers – heat flux density measurements (in Polish), Publishing House of Silesian University of Technology, pp. 139-149, Gliwice.
  • [7] Taler J., 1995. Theory and practice of identification of thermal flow processes, Ossolineum, Wrocław.
  • [8] Taler J., Duda P., Węglowski B., Zima W., Grądziel S., Sobota T., Taler D., 2009. Identification of local heat flux to membrane water-walls in steam boilers, Fuel 88, pp. 305–311.
  • [9] Grądziel S., 2008. The steam boiler furnace chamber calculations using the zone method (in Polish), Archives of Energetics, Vol. XXXVIII, No 1, pp. 191-202.
  • [10] Taler J., Taler D., Ludowski P., 2014, Measurements of local heat flux to membrane water walls of combustion chambers, Vol. 115, s. 70-83.
  • [11] Kuznetsov N.W., Nitor W.W., Dubovski I.E., Karasina E.S., 1973. Thermal Calculations of Steam Boilers. Standard Method (in Russian), Energy, Moscow.
  • [12] Wojciechowski M., 2012. Designing of the supercritical boilers on the example of steam boiler in Bełchatów Power Plant, Final Project, Cracow University of Technology (in Polish).