Measurements and Simulations of Very Fast Transients during Disconnector Type Testing in UHV Gas-Insulated Switchgear

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Pomiary i symulacje przepięć szybkozmiennych w gazowych rozdzielnicach najwyższych napięć w układzie próby typu odłącznika
Języki publikacji
EN
Abstrakty
EN
Increasing power demand in China requires an efficient and reliable transmission system at highest voltage levels of 1100 kV AC. The paper presents measurement and simulation results performed for UHV disconnector testing in demonstration pilot project in China. Very Fast Transient Overvoltages impact on the disconnector design is investigated. A new approach of Trapped Charge Voltage analysis is presented wchich allows one to select the design optimized for more realistic calculation of overvoltages due to the disconnector operations.
PL
Rosnące zapotrzebowanie na moc elektryczną w Chinach skutkuje ciągłym podwyższaniem napięć przesyłowych w celu ograniczenia strat mocy. W gazowych rozdzielnicach najwyższych napięć istotnym zagadnieniem jest analiza przepięć spowodowanych operacją odłącznika. W artykule przedstawiono wyniki pomiarów i symulacji przeprowadzonych w układzie próby typu odłącznika w celu ograniczania przepięć poprzez zmianę prędkości rozchodzenia się styków odłącznika.
Rocznik
Strony
150--153
Opis fizyczny
Bibliogr. 6 poz., rys., wykr., wz.
Twórcy
autor
  • ABB Corporate Research Center, Poland
autor
  • ABB Corporate Research Center, Poland
autor
  • ABB Corporate Research Center, Poland
autor
  • AGH University of Science and Technology
autor
  • ABB Corporate Research Center, Poland
  • ABB Corporate Research Center, Poland
autor
  • ABB High Voltage Products, Switzerland
Bibliografia
  • [1] Riechert U., Holaus W., Ultra high-voltage gas-insulated switchgear – a technology milestone, European Transactions On Electrical Power 2011; 22:60–82
  • [2] IEC 62271-203 High-Voltage Switchgear and Controlgear – Part 203: “Gas-Insulated Metal-enclosed Switchgear for Rated Voltages Above 52 kV”
  • [3] Ecklin G., Schlicht D., Overvoltages in GIS Caused by the Operation of Isolators, Proceedings of the Brown Boveri Research Centre, Baden, Switzerland, September 3-4, 1979, 115-128
  • [4] IEC 62271-102, High-Voltage Switchgear and Controlgear – Part 102: Alternating Current Disconnectors and Earthing Switches
  • [5] Szewczyk M., Stosur M., Piasecki W., Fulczyk M., Florkowski M., Steiger M., Kostovic J., New Disconnector Model for Very Fast Transient Studies in High Voltage Gas Insulated Substations, in Proc. 2010 EEUG (European EMTP-ATP User Group) Conf., 154-163
  • [6] Szewczyk M., Piasecki W., Stosur M., Riechert U., Kostovic J., Impact of Disconnector Design on Very Fast Transient Overvoltages in Gas-Insulated UHV Switchgear, Proceedings of 17th International Symposium on High Voltage Engineering (ISH), August 22nd – 26th, Hannover, Germany