PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Microstructure and Functional Properties of Prosthetic Cobalt Alloys CoCrW

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Mikrostruktura i właściwości użytkowe protetycznych stopów kobaltu CoCrW
Języki publikacji
EN
Abstrakty
EN
The material subject to investigation was two commercial alloys of cobalt CoCrW (No. 27 and 28) used in prosthodontics. The scope of research included performing an analysis of microstructure and functional properties (microhardness, wear resistance and corrosion resistance), as well as dilatometric tests. The examined alloys were characterized by diverse properties, which was considerably influenced by the morphology of precipitates in these materials. Alloy No. 27 has a higher corrosion resistance, whereas alloy No. 28 shows higher microhardness, better wear resistance and higher coefficient of linear expansion. Lower value of the expansion coefficient indicates less probability of initiation of a crack in the facing ceramic material.
PL
Badaniu poddano dwa komercyjne stopy kobaltu CoCrW (nr 27 i 28) stosowane w protetyce stomatologicznej. Zakres badań obejmował przeprowadzenie analizy mikrostrukturalnej, właściwości użytkowych (mikrotwardość, odporność na ścieranie i odporność korozyjna) oraz badania dylatometryczne. Badane stopy charakteryzowały się zróżnicowanymi właściwościami na co zasadniczy wpływ miała morfologia wydzieleń w tych materiałach. Stop nr 27 posiada wyższą odporność korozyjną natomiast stop nr 28 wykazuje: wyższą mikrotwardość, lepszą odporność na ścieranie oraz niższy współczynnik rozszerzalności liniowej. Niższa wartość współczynnika rozszerzalności liniowej wskazuje na mniejsze prawdopodobieństwo inicjacji pęknięcia licującego materiału ceramicznego.
Twórcy
autor
  • Czestochowa University of Technology, Department of Foundry, 19 Armii Krajowej Av., 42-200 Częstochowa, Poland
autor
  • Czestochowa University of Technology, Institute of Materials Engineering, 19 Armii Krajowej Av., 42-200 Częstochowa, Poland
autor
  • Czestochowa University of Technology, Department of Foundry, 19 Armii Krajowej Av., 42-200 Częstochowa, Poland
autor
  • Czestochowa University of Technology, Institute of Materials Engineering, 19 Armii Krajowej Av., 42-200 Częstochowa, Poland
  • Department of Normal And Clinical Anatomy, Interfaculty Chair of Anatomy And Histology, Medical University of Lodz
Bibliografia
  • [1] I. Peter, M. Rosso, A. Toppi, I. Dan, B. Ghiban, Arch, Mat. Sci. Engi. 61, 62 (2013),
  • [2] L. Reclaru, H. Lüthy, P.Y. Eschler, A. Blatter, O. Loeffel, M. H Zurcher, Euro. Cel. Mate. 7, 51 (2004),
  • [3] R. Prabhu, K. R. Geetha Prabhu, T. Ilango, Jour. Clin. Diag. Res. 5(8), 1682 (2011),
  • [4] L. Reinmann, L. A. Dobrzański, Arch, Mat. Sci. Engi. 60, 5 (2013),
  • [5] L. A. Dobrzański, L. Reinmann, Jour. Achie. Mate. Manu. Engi. 49,193 (2011),
  • [6] Z. Komorek, S. Jóźwiak, M. Kuchta, Arch. Odle. 6, 279 (2006),
  • [7] S.W. Majewski, Prot. Stom. 7, 124 (2007),
  • [8] M. Gładkowska, P. Montefka, P. Okoński,, Prot. Stom. 8, 105 (2008),
  • [9] F. Noack, Inter. Jour. Dental Tech. 13, 2 (2012),
  • [10] A. Łukaszczyk, J. Augustyn-Pieniążek, Arch. Met. Mat., 60, 523 (2015),
  • [11] D. Klimecka-Tatar, K. Radomska, G. Pawłowska, Jour. Balk. Tribol. Assoc. 21, 204 (2015),
  • [12] K. Beer-Lech, M. Szala, P. Piskorska, Ł. Majewski, Badania lejności i twardości stomatologicznego stopu odlewniczego na osnowie kobaltu, in Materials Engineering - Selected issues from materials engineering (2013),
  • [13] L. E. Ramirez, M. Castro, M. Mendez, J. Lacaze, M. Herrera, G. Lesoult, Sc. Mater., 47, 811 (2002)
  • [14] J. Augustyn–Pieniążek, A. Łukaszczyk, R. Zapała, Arch. Metal. Mater. 58, 1281 (2013),
  • [15] Sh. Zangeneh, H. R. Lashagari, A. Roshani, Mater. Design 37, 292 (2012),
  • [16] J. V. Giacchi, C. N. Morando, O. Fornaro, H. A. Palacio, Mater. Charact., 62, 53 (2011).
Typ dokumentu