Wpływ procesów oczyszczania ścieków w technologii SBR na stan sanitarny powietrza atmosferycznego

Treść / Zawartość
Identyfikatory
Warianty tytułu
EN
Effect of wastewater treatment processes in SBR technology on sanitary condition of atmospheric air
Języki publikacji
PL
Abstrakty
EN
Most processes of sewage treatment contribute to the emission of microorganisms to the air, and this most frequently takes place during an intensive flow or processes of aeration. The aim of this study was to assess the effect of individual devices of the sewage treatment plant on the degree of microbiological air pollution in the premises and in the vicinity of the tested facility. The air analyses were carried out at a mechanical and biological sewage treatment plant with an increased degree of removing organic compounds in the SBR technology of on average 1786 m3 /d. In the experiment there was used the common compaction method using the sampler SAS 100. 8 research sites were appointed, including the control (background). It was found that the main source of bioaerosol emission in the studied sewage treatment plant was the decompression chamber and the Imhoff tank, and to a lesser degree, aeration chambers. For all the time of collecting samples no exceeding of permissible norms of the total number of bacteria and fungi in the air was observed. The number of staphylococci indicated that the air at all the technological facilities throughout the measurement period was moderately polluted. During all the experiment the average air pollution occurred under the influence of the presence of Pseudomonas fluorescens. The fungi species most frequently occurring in the air on the premises of the treatment plant included: Penicillium notatum, Penicillium waksmani and Penicillium viridicatum, Mucor racemosus and Cladosporium herbarum. Also Alternaria alternata occurred at all the sampling points, but this took place only in the spring period. During the conducted studies, the following species of the familyEnterobacteriaceae and other Gram-negative bacilli were determined in the air samples: Escherichia coli, Citrobacter freundii, Enterobacter cloacae, Proteus vulgaris, Serratia liquefaciens, Salmonella spp., K.pneumoniae, K.oxytoca, Yersinia enterocolitica, Vibrio, fluvialis, Pseudomonas putida, P.fluorescens and Aeromonas hydrophila. Based on the conducted assessment of air pollution on the premises of the sewage treatment plant, the occurrence of numerous microorganisms was observed. Their main emission sources were SBR reactors, bare screen stations, the Imhoff tank and the place of sludge storage. The air was assessed as moderately polluted with the bacteria Pseudomonas fluorescens, actinomyces and hemolytic staphylococci. The occurrence in the air of numerous bacteria species of the family Enterobacteriaceae poses a hazard to people employed at the sewage treatment plant.
Rocznik
Strony
904--923
Opis fizyczny
Bibliogr. 23 poz., tab., rys.
Twórcy
  • Uniwersytet Technologiczno-Przyrodniczy, Bydgoszcz
  • Uniwersytet Technologiczno-Przyrodniczy, Bydgoszcz
autor
  • Uniwersytet Technologiczno-Przyrodniczy, Bydgoszcz
autor
  • Uniwersytet Technologiczno-Przyrodniczy, Bydgoszcz
autor
  • Uniwersytet Technologiczno-Przyrodniczy, Bydgoszcz
autor
  • Uniwersytet Technologiczno-Przyrodniczy, Bydgoszcz
Bibliografia
  • 1. Breza-Boruta B., Paluszak Z.: Influence of water treatment plant on microbiological composition of air bioaerosol. PJOES, 16, 5, 663–670 (2007).
  • 2. Breza-Boruta B., Paluszak Z.: Ocena oddziaływania oczyszczalni ścieków na stopień mikrobiologicznego zanieczyszczenia powietrza. Przemysł Chemiczny, 89, 4, 324–329 (2010).
  • 3. Budzińska K., Michalska M.: Zanieczyszczenie mikrobiologiczne powietrza na terenie oczyszczalni ścieków z zakładów mięsnych. Zesz. Nauk. Wyd. Budow. Inż. Środ. Politechnika Koszalińska, 20, 581–597 (2001).
  • 4. Budzińska K., Jurek A., Szejniuk B., Michalska M., Wroński G.: Mikrobiologiczne zanieczyszczenie powietrza na terenie oczyszczalni ścieków komunalnych. Rocznik Ochrona Środowiska (Annual Set The Environment Protection), 13, 1543–1558 (2011).
  • 5. Carducci A., Tozzi E., Rubulotta E., Casini B., Cantiani1 L., Rovini E., Muscillo M., Pacini R.: Assessing airborne biological hazard from urban wastewater treatment. Water Research, 34, 4, 1173–1178 (2000).
  • 6. Fassatiova O.: Grzyby mikroskopowe w mikrobiologii technicznej. WNT Warszawa, 1983.
  • 7. Filipkowska Z., Janczukowicz W., Krzemieniewski M., Pesta J.: Microbiological air pollution in the surroundings of the wastewater treatment plant with activated-sludge tanks aerated by horizontal rotors. PJOES, 9, 4, 273–280 (2000).
  • 8. Filipkowska Z., Janczukowicz W., Krzemieniewski M., Pesta J.: Municipal wastewater treatment plant with sctivated sludge tanks aerated by CELPOX devices as a source of microbiological pollution of the atmosphere. PJOES, 11, 6, 639–648, 2002.
  • 9. Fracchia L., Pietronave S., Rinaldi M., Martinotti M.G.: The assessment of airborne bacterial contamination in three composting plants revealed site-related biological hazard and seasonal variations. J. Appl. Microbiol., 100, 973–984 (2006).
  • 10. Friis L.: Health of municipal sewage workers. Studies of cancer incidence, biomarkers of carcinogenicity and genotoxicity, and self reported symptoms. Acta Universitatis Upsaliensis. Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, 1015, 1–67 (2001).
  • 11. Kalisz L., Sabłut J., Kaźmierczuk M.: Miejska oczyszczalnia ścieków jako źródło mikrobiologicznego zanieczyszczenia powietrza. Ochr. Środ. i Zasob. Natur., 7, 33–54 (1994).
  • 12. Kołwzan B., Jadczyk P., Pasternak G., Głuszczak J., Pawlik M., Krawczyńska M., Klein J., Rybak J.: Ocena stanu sanitarnego powietrza w otoczeniu wybranej oczyszczalni ścieków. Ochrona Środowiska, 34, 2, 9–14 (2012).
  • 13. Korzeniewska E., Filipkowska Z., Gotkowska-Płachta A.: Miejska oczyszczalnia ścieków jako emitor bakterii z rodziny Enterobacteriaceae do powietrza. Ochr. Środ. i Zasob. Natur., 32, 178–182, 2007a.
  • 14. Korzeniewska E., Filipkowska Z., Gotkowska-Płachta A.: Miejska oczyszczalnia ścieków z komorami osadu czynnego, napowietrzanymi aeratorami typu Celpox jako emitor bakterii z rodziny Enterobacteriaceae do powietrza. Ochr. Środ. i Zasob. Natur., 32, 184–188, 2007b.
  • 15. Korzeniewska E., Filipkowska Z., Gotkowska-Płachta A., Janczukowicz W.: Bakteriologiczne zanieczyszczenie powietrza na terenie i w otoczeniu oczyszczalni ścieków z systemem filtrów gruntowo-roślinnych. Woda-Środowisko-Obszary Wiejskie, 8, 1, 22, 161–173 (2008).
  • 16. Krzysztofik B.: Mikrobiologia powietrza. Wyd. Uczeln. Politech. Warszawskiej, 1986.
  • 17. Michałkiewicz M., Pruss A., Dymaczewski Z., Michalak J.: Wpływ hermetyzacji wybranych etapów oczyszczania ścieków na mikrobiologiczne zanieczyszczenie powietrza. Polska Inżynieria Środowiska pięć lat po wstąpieniu do Unii Europejskiej. Monografie. Komitet Inżynierii Środowiska, PAN Lublin, 2, 59, 135–143 (2009).
  • 18. Ossowska-Cypryk K.: Zastosowanie mikroorganizmów wskaźnikowych do oceny stopnia zanieczyszczenia powietrza w otoczeniu oczyszczalni ścieków przemysłowych. GWTiS, 65, 5, 105–110 (1991).
  • 19. Piekarska T., Traczewska T.M.: Wpływ oczyszczalni ścieków na jakość mikrobiologiczną powietrza. Ochrona Powietrza i Problemy Odpadów, 36, 1, 19–25 (2002).
  • 20. Przybulewska K., Czupryniak M.: Microbial quality of air in various seasons under the influence of emissions from sewage treatment plant. Environ. Prot. Eng., 32, 3, 25–30 (2006).
  • 21. Prażmo Z., Krysińska-Traczyk E., Skórska Cz., Sitkowska J., Cholewa G., Dutkiewicz J.: Exposure to bioaerosols in a municipal sewage treatment plant. Ann. Agric. Environ. Med., 10, 241–248 (2003).
  • 22. Wlazło A., Pastuszka J.S., Łudzień-Izbińska B.: Ocena narażenia na aerozol bakteryjny pracowników niedużej oczyszczalni ścieków. Med. Pracy, 53, 2, 100–114 (2002).
  • 23. Teltsch B., Kedmi S., Bonnet L., Borenzstajn-Rotem Y., Katzenelson E.: Isolation and identification of pathogenic microorganisms at wastewater-irrigated fields: ratios in air and wastewater. Appl. Environ. Microbiol., 39, 6, 1183–1190 (1980).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-4c045b72-0e56-45d2-a3f6-b0231b4d7d4f
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.