Ultrafine particles and nanoparticles in the air are evaluated as a risk factor for the development of respiratory and other health symptoms due to their inhalation from the ambient air. The Czech Army professionals are expected to have frequent presence in a polluted environment and regular exposure to air with increased concentration of airborne pollutants. The report evaluates the presence of ultra-fine particles (in the range of about 7.6–299.6 nm) in rooms often used by soldiers during their working hours when they are not deployed. The purpose is to assess whether the presence of troops in these workplaces is safe and does not pose a risk of adverse health effects in itself. Testing took place in three military rooms (classroom 1, classroom 2 and exercise flight simulator room). Seven samples of air were analysed in time by the scanning mobility particle sizer in succession. Mean particle concentrations were found at 1.79×104, 7.53×103 and 8.39×103 N·cm-3 for the classroom 1, classroom 2 and exercise flight simulator room. Conclusions of the research have shown that particle concentrations in the places of the Czech Army can reach values that border the immission limits stated by the World Health Organisation.
PL
Najdrobniejsze cząstki i nanocząsteczki w powietrzu są oceniane jako czynnik ryzyka dla dróg oddechowych i innych objawów zdrowotnych spowodowanych ich wdychaniem z otaczającego powietrza. Oczekuje się, że specjaliści z czeskiej armii będą często obecni w zanieczyszczonym środowisku i będą regularnie narażeni na kontakt z powietrzem o zwiększonej koncentracji zanieczyszczeń. Raport ocenia obecność ultradrobnych cząstek (w zakresie około 7,6–299,6 nm) w pomieszczeniach często używanych przez żołnierzy w godzinach pracy. Celem jest ocena, czy obecność wojsk w tych miejscach pracy jest bezpieczna i sama w sobie nie stwarza ryzyka negatywnych skutków zdrowotnych. Testowanie odbyło się w trzech pomieszczeniach wojskowych (sala 1, sala 2 i sala do ćwiczeń). Siedem próbek powietrza analizowano w czasie przez separator cząstek. Stwierdzone średnie stężenia cząstek 1,79 × 104, 7,53 × 103 i 8,39 × 103 [N · cm-3] w sali lekcyjnej 1, klasie 2 i sali do ćwiczeń. Wnioski z badań wykazały, że stężenia cząstek w wybranych pomieszczeniach czeskiej armii mogą osiągnąć wartości graniczące z limitami imisji podanymi przez Światową Organizację Zdrowia.
Rocznik
Strony
163--167
Opis fizyczny
Bibliogr. 13 poz., rys., tab., wykr.
Twórcy
  • Department of Emergency Management, Faculty of Military Leadership, University of Defence, Kounicova 65, 662 10 Brno, Czech Republic
  • Department of Environmental Analytical Chemistry, Institute of Analytical Chemistry CAS, Veveří 967/97, 602 00 Brno, Czech Republic
  • Department of Emergency Management, Faculty of Military Leadership, University of Defence, Kounicova 65, 662 10 Brno, Czech Republic
autor
  • Department of Emergency Management, Faculty of Military Leadership, University of Defence, Kounicova 65, 662 10 Brno, Czech Republic
Bibliografia
  • 1. CZECH REPUBLIC. Law no. 201/2012 Coll. on air protection, as amended. Prague: Collection of Laws, 2012, 78 p.
  • 2. GONG, Longwen et al. Ultrafine Particles Deposition Inside Passenger Vehicles. Aerosol Science and Technology. Vol. 43, 2009, pp 544-553, ISSN 0278-6826.
  • 3. MCAULEY, TR et al. Relationships of outdoor and indoor ultrafine particles at residences downwind of a major international border crossing in Buffalo, NY. Indoor Air. Vol. 20, 2010, pp 298-308, ISSN 1600-0668.
  • 4. Archive: Weather in Brno [online]. c2018 [cit. 2018-02-26]. Available at: <https://www.meteocentrum.cz/zajimavo- sti/archiv-pocasi/prubeh-pocasi-v-brne>
  • 5. MINISTRY OF THE ENVIRONMENT OF THE CZECH REPUBLIC. Information on Health Risks Related to Air Quality in 2015. Prague: Ministry of the Environment of the Czech Republic, 2015, 25 p.
  • 6. MORAWSKA, L et al. Indoor aerosols: from personal exposure to risk assessment. Indoor Air. Vol. 23, 2013, p 462- 487, ISSN 1600-0668.
  • 7. NINDL, BC et al. Physiological Employment Standards III: physiological challenges and consequences encountered during international military deployments. European Journal of Applied Physiology. Vol. 113, 2013, p 2655-2672, ISSN 1439-6319.
  • 8. Traffic slope 2016 [Online]. c2018 [cit. 20 3 2018]. Available at: http://scitani.rsd.cz/.
  • 9. TSI. Aerosol Instrument Manager® Software. USA: TSI, 2010.
  • 10. VEČEŘA, Zbyněk et al. Nanoparticles and their health risks. In: National Center of Nursing and Non-Medical Health Care 2012 in Brno. Prague: Institute of Experimental Medicine of the Czech Academy of Sciences, 2012, pp 33-35, ISBN 978-80-7013-546-4.
  • 11. VIANA, M et al. Partitioning of trace elements and metals between quasi-ultrafine, accumulation and coarse aero- sols in indoor and outdoor air in schools. Atmospheric Environment. Vol. 106, 2015, pp 392-401, ISSN 1352-2310.
  • 12. WORLD HEALTH ORGANISATION. Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulfur dioxide (Global update). Summary of risk assessment. Geneva: World Health Organisation, 2005, 22 p.
  • 13. ZHAO, S et al. Effective Density of Submicron Aerosol Particles in a Typical Valley City, Western China. Aerosol and Air Quality Research. Vol. 17, 2016, 13 p, ISSN 1680-8584.