Realisation of radionuclides activity unit using the liquid scintillation counting (LSC)

Treść / Zawartość
Identyfikatory
Warianty tytułu
PL
Odtwarzanie jednostki aktywności radionuklidów za pomocą techniki ciekłych scyntylatorów (LSC)
Języki publikacji
EN
Abstrakty
EN
Registration of the effects of interaction of the radiation emitted after radioactive decay enables determination of activity of a given material expressed in becquerels (Bq). Measurements in a frame of international comparisons of 14 C activity using the triple-to-double coincidence ratio (TDCR) method and of 177 Lu activity using the 4π(LS)-γ coincidence and anticoincidence method, where the liquid scintillation technique (LSC) was used, were described. Specificity of short-lived radionuclides activity determination was discussed.
PL
Rejestracja oddziaływania z materią promieniowania emitowanego w czasie rozpadów promieniotwórczych umożliwia określenie aktywności danego materiału w bekerelach (Bq). Omówiono wykonane w trakcie międzynarodowych porównań pomiary aktywności 14 C metodą potrójno-podwójnych koincydencji (TDCR) oraz 177 Lu metodą 4π(LS)-γ koincydencji i antykoincydencji, w których zastosowana jest technika ciekłych scyntylatorów (LSC). Omówiono specyfikę pomiaru aktywności radionuklidów krótkożyciowych.
Rocznik
Tom
Strony
28--31
Opis fizyczny
Bibliogr. 12 poz., rys., tab.
Twórcy
autor
  • National Centre for Nuclear Research Radioisotope Centre POLATOM
autor
  • National Centre for Nuclear Research Radioisotope Centre POLATOM
autor
  • National Centre for Nuclear Research Radioisotope Centre POLATOM
  • National Centre for Nuclear Research Radioisotope Centre POLATOM
Bibliografia
  • [1] Bouchard J.: MTR: a discriminator and dead-time module used in counting system. Appl. Radiat. Isot., 52/2000, 441–446.
  • [2] Broda R., Capogni M., Dziel T., Fazio A., Listkowska A., Ziemek T.: International comparison of activity measurements of a solution of 14C. NCBJ Report (to be published).
  • [3] Broda R., Cassette P., Kossert K.: Radionuclide metrology using liquid scintillation counting, Metrologia, 44/2007, 36–52.
  • [4] Broda R.: A review of the triple-to-double coincidence ratio (TDCR) method for standardizing radionuclides. Appl. Radiat. Isot., 58/2003, 585–594.
  • [5] Chyliński A., Broda R., Radoszewski T.: The national standard unit of radionuclide activity and related standards in Poland, NUKLEONIKA, 48/2003, 51–55.
  • [6] Joint Committee for Guides in Metrology (JCGM). Evaluation of measurement data – Guide to the expression of uncertainty in measurement (GUM), JCGM 100:2008.
  • [7] L’Annunziata M.F.: Handbook of Radioactivity Analysis, Acad. Press, Elsevier, Amsterdam, Boston, Heidelberg, London, New York, Oxford, Paris, San Diego, San Francisco, Sydney, Tokyo, 2012.
  • [8] Michotte C. et al.: Comparison of 18F activity measurements at the VNIIM, NPL and the ENEA–INMRI using the SIRTI of the BIPM. Appl. Radiat. Isot., 109/2016, 17–23.
  • [9] Ratel G.: Evaluation of the uncertainty of the degree of equivalence. Metrologia, 42/2005, 140–144.
  • [10] Ratel, G.: The Systeme International de Reference and its application in key comparisons. Metrologia, 44/2007, 7–16.
  • [11] Ziemek T., Jęczmieniowski A., Cacko D., Broda R., Lech E.: A new 4π(LS)-γ coincidence counter at NCBJ RC POLATOM with TDCR detector in the beta channel. Appl. Radiat. Isot., 109/2016, 290–295.
  • [12] Zimmerman B.E. et al.: Results of an international comparison for the activity measurement of 177Lu. Appl. Radiat. Isot., 70/2012, 1825–1830.
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-495c3761-653d-446a-982a-09f545d40dea
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.