Tytuł artykułu
Treść / Zawartość
Pełne teksty:
Identyfikatory
Warianty tytułu
Zanieczyszczenie mikrobiologiczne wody pochodzącej z fontann zlokalizowanych w uzdrowisku Ciechocinek
Języki publikacji
Abstrakty
Fountains located in health resorts frequently serve as therapeutic waters intended for recreational and balneological purposes. Therefore, the quality of water and air around such objects is crucial for patients using the fountains. Fountain water conducive to the occurrence of pathogen microorganisms, such as: coliform bacteria, staphylococci, streptococci, Salmonella spp. and microscopic fungi. They mostly cause a gastrointestinal and skin infections. The research here presented aimed at the assessment of the degree of bacterial and fungal contamination of water samples taken from fountains located in the Ciechocinek health resort from the perspective of biosafety of tourists and patients. Microbiological analysis of the water sample was taken from four fountains (object A-D), one of which (object C) was supplied with brine water.The plate method was used to determination of a total count of bacteria and a total count of fungi in the water samples. For the quantitative determination of coliform bacteria, Escherichia coli, staphylococci and streptococci, the membrane filter technique was employed. The studies showed that the samples of water from fountains contained bacteriological and mycological contamination in which microfungi being the most abundant group. The water samples contained a few cells of E. coli, fecal streptococci and staphylococci. The most frequently indentified indicator bacteria in sample water from fountain D were faecal streptococci (3.17·101 cfu/100 ml). The water samples coming from the object B and D and in most water samples from the object C, there was no presence of these bacteria. As the data indicate, the largest differences regarding the population of those microorganisms were between water samples taken from Fountain B and C. The highest frequency of the occurrence of the E. coli bacilli was recorded in fountain A, while they occurred once in research series 5 taken from fountain C. The mean amount of these bacteria in the water samples taken from Fountain D was 5.76·100 cfu/100 ml, which was more than 40 times higher than the mean population of these microorganisms isolated from the water taken from Fountain C (0.14·100 cfu/100 ml). The studies demonstrate that the least number of coliform bacteria and E. coli was found in fountain C, where 4.51% brine water was used. The highest number of staphylococci during the entire research period was determined in water sample taken from fountain D (7.9·101 cfu/100 ml), while in water sample taken from fountains A and C and in sample from fountain B, no such bacteria were found. Occurrence of faecal bacteria, staphylococci and microscopic fungi in water may pose a risk of diseases for people who use the fountains. The research indicated that it is necessary to perform monitoring of fountain water and introduce legal regulations regarding its sanitary and hygiene condition.
Fontanny zlokalizowane na terenach uzdrowiskowych często są wykorzystywane jako wody lecznicze przeznaczone do celów rekreacyjnych oraz balneologicznych. W związku z tym bardzo ważna dla kuracjuszy korzystających z fontann jest jakość wody i powietrza wokół tych obiektów. Woda pochodząca z fontann sprzyja występowaniu mikroorganizmów chorobotwórczych takich jak: bakterie grupy coli, gronkowce, paciorkowce, pałeczki z rodzaju Salmonella oraz grzyby mikroskopowe. Powodują one przede wszystkim zakażenia o charakterze żołądkowo-jelitowym oraz infekcje skórne. Celem pracy była ocena stopnia zanieczyszczenia bakteriologicznego i mikologicznego próbek wody pobieranych z fontann, zlokalizowanych na terenie uzdrowiska Ciechocinek w aspekcie bezpieczeństwa sanitarnego turystów i kuracjuszy. Analizie mikrobiologicznej poddano próbki wody pobrane z czterech fontann (obiekty A-D), z których jedna (obiekt C) była zasilana wodą solankową. Metodą płytkową oznaczono ogólną liczbę bakterii i grzybów mikroskopowych. Do oznaczenia ilościowego bakterii grupy coli, Escherichia coli, paciorkowców kałowych oraz gronkowców wykorzystano metodę filtrów membranowych. W wyniku przeprowadzonych badań stwierdzono, że próbki wody pochodzące z fontann zawierały zanieczyszczenia bakteriologiczne i mikologiczne, przy czym najliczniej reprezentowane były grzyby mikroskopowe. W próbkach wody występowały pojedyncze komórki E. coli a także paciorkowce kałowe oraz gronkowce. Najliczniej paciorkowce kałowe identyfikowano w próbce wody pobranej z fontanny D (3,17·101 jtk/100 ml). W próbkach wody pochodzących z obiektu B i D oraz w większości próbek wody z obiektu C nie stwierdzono obecności tych bakterii. Największe różnice dotyczące liczebności tych mikroorganizmów wystąpiły w przypadku próbek wody pochodzących z fontanny B i C. W obiekcie A notowano najwyższą częstotliwość występowania pałeczek E. coli, natomiast w przypadku fontanny C występowały one w jednym przypadku w wody pochodzącej z 5 serii badawczej. Średnia liczba bakterii Escherichia coli w próbkach wody pobranej z obiektu D wynosiła 5,76·100 jtk/100 ml i była ponad 40-krotnie wyższa od średniej liczebności tych drobnoustrojów izolowanych z wody pochodzącej z obiektu C (0,14·100 jtk/100 ml). Badania wykazały, że najmniej bakterii grupy coli i E. coli stwierdzono w obiekcie C, w którym wykorzystywano wodę solankową o zasoleniu 4,51%. Największą liczbę gronkowców w ciągu całego okresu badań oznaczono w próbce wody pobranej z obiektu D (7,9·101 jtk/100 ml), natomiast w niektórych próbkach wody ujętej z obiektu A i C oraz B nie stwierdzono obecności tych bakterii. Występowanie w wodzie bakterii fekalnych, gronkowców, jak również grzybów mikroskopowych może stwarzać ryzyko zachorowań u ludzi korzystających z fontann. Przeprowadzone badania wskazują na konieczność prowadzenia monitoringu wody pochodzącej z fontann, a także na wprowadzenie regulacji prawnych dotyczących ich stanu sanitarno-higienicznego.
Wydawca
Czasopismo
Rocznik
Tom
Strony
181--199
Opis fizyczny
Bibliogr. 23 poz., tab., rys.
Twórcy
autor
- University of Science and Technology, Bydgoszcz
autor
- University of Science and Technology, Bydgoszcz
autor
- University of Science and Technology, Bydgoszcz
autor
- University of Science and Technology, Bydgoszcz
autor
- University of Science and Technology, Bydgoszcz
autor
- University of Science and Technology, Bydgoszcz
autor
- University of Science and Technology, Bydgoszcz
Bibliografia
- 1. Biedunkiewicz, A. (2009). Microfungi of municipal fountains in environmental monitoring – an epidemiological threat. Ochrona Środowiska i Zasoby Naturalne, 41, 163-171.
- 2. Burkowska, A., Donderski, W. (2006). Wpływ otwartych inhalatoriów na mikrobiologicznystan powietrza uzdrowiska Ciechocinek. Acta Agraria et Silvestria. Series Agraria, 49, 111-119.
- 3. Burkowska, A., Donderski, W. (2007). Bacterial pollution of air in health resort Ciechocinek. Polish Journal of Natural Sciences, 22(4), 633-644.
- 4. Burkowska, A., Kalwasińska, A., Walczak, M. (2012). Airborne mesophilic bacteria at the Ciechocinek health resort. Polish Journal of Environmental Studies, 21(2), 307-3111.
- 5. Burkowska-But, A., Swiontek Brzezinska, M., Walczak, M. (2013). Microbiological contamination of water in fountains located in the city of Toruń. Annals of Agricultural and Environmental Medicine, 20(4), 645-648.
- 6. Dz.U. 2011 nr 86 poz. 478. Rozporządzenie Ministra Zdrowia z dnia 8 kwietnia 2011 r. w sprawie prowadzenia nadzoru nad jakością wody w kąpielisku i miejscu wykorzystywanym do kąpieli.
- 7. Eisenstein, L., Bodager, D., Ginzl, D. (2008). Outbreak of giardiasis and cryptosporidiosis associated with a neighborhood interactive water fountain – Florida, 2006. Journal of Environmental Health, 71(3), 18-22.
- 8. Fernández, E. E., Saldaña, L. J., Rodríguez, G. O., Cliver, D.O. (2002). Potential Salmonella transmission from ornamental fountains. Journal of Environmental Health, 65(4), 9-12, 22.
- 9. Fleming, C.A., Caron, D., Gunn, J.E., Horine, M.S., Matyas, B.T., Barry, M.A. (2000). An outbreak of Shigella sonnei associated with a recreational spray fountain. American Journal Public Health, 90(10), 1641-1642.
- 10. Flores C., Loureiro L., Bessa L., Martins da Costa P., 2013: Presence of multidrug- resistant E.coli, Enterococcus spp. and Salmonella spp. in lakes and fountains of Porto, Portugal. Journal of Water Resource and Protection, 5(11), 1117-1126.
- 11. Haupt, T.E., Heffernan, R.T., Kazmierczak, J.J., Nehls-Lowe, H., Rheineck, B., Powell, Ch., Leonhardt, K.K., Chitnis, A.S., Davis, J.P. (2012). An outbreak of legionnaires disease associated with a decorative water wall fountain in a hospital. Infection Control & Hospital Epidemiology, 33(2), 85-191.
- 12. Hlavsa, M.C., Roberts, V.A., Kahler, A.M., Hilborn, E.D., Wade, T.J., Backer, L.C., Yoder, J.S. (2014). Recreational water-associated disease outbreaks- United States, 2009-2010. Morbidity and Mortality Weekly Report, 64(24), 6-10
- 13. Hoebe, C.J.P.A., Vennema, H., de Roda Husmna, A.M., van-Duynhoven, Y.T. (2004). Norovirus outbreak among primary schoolchildren who had played in a recreational water fountain. The Journal of Infectious Diseases, 189(4), 699-705.
- 14. Jones, M., Boccia, D., Kealy, M., Salkin, B., Ferrero, A., Nichols, G., Stuart, J.M. (2006). Cryptosporidium outbreak linked to interactive water feature, UK: importance of guidelines. Eurosurveillance, 11(4-6), 126-128.
- 15. Kirian, M.L., Merefillano, G., Gennette, D., Weintraub, J. M. (2008). Multijurisdictional investigation of interactive fountain associated cryptosporidiosis and salmonellosis outbreaks. Epidemiology & Infection, 136(11), 1547-1551.
- 16. Minshew, P., Ward, K., Mulla, Z., Hammond, R., Johnson, D., Heber, S., Hopkins, R. (2000). Outbreak of gastroenteritis associated with an interactive water fountain at a beachside park – Florida, 1999. Morbidity and Mortality Weekly Report, 49(25), 565-568.
- 17. Office of Surveillance, Epidemiology, and Laboratory Services, Centers for disease control and prevention (CDC), U.S. Department of health and human services, Atlanta, GA 30333, (2011). Surveillance for waterborne disease outbreaks and other health events associated with recreational water- United States, 2007-2008 and surveillance for waterborne disease outbreaks associated with drinking water – United States, 2007-2008. Morbidity and Mortality Weekly Report, 60(12), 1-75.
- 18. PN-EN ISO 19458:2007 (2007). Pobieranie próbek wody do badań mikrobiologicznych. Warszawa: Wydawnictwo PKN.
- 19. Roscoe, T., Sloan, D., Cooper, T., Morton, B., Hunter, I. (2000). A waterborne outbreak of Morbidity and Mortality Weekly Report Saintpaul. Communicable Diseases Intelligence, 24(11), 336-340.
- 20. Sezen, F., Aval, E., Agkurt, T., Yilmaz, Ş., Temel, F., Güleşen, R., Korukluoğlu, G., Sucakli, M.B., Torunoğlu, M.A. (2014). A large multipathogen gastroenteritis outbreak caused by drinking contaminated water from antique neighbourhood fountains, Erzurum city, Turkey, December 2012. Epidemiology & Infection, 143(4), 704-710.
- 21. Szczygłowska, R., Chyc, M., Burzała, B., Kołwzan, B. (2012). Ocena jakości bakteriologicznej i fizyko-chemicznej wody basenowej w wybranym krytym obiekcie rekreacyjnym. Ochrona Środowiska, 34(4), 52-56.
- 22. Szejniuk, B., Budzińska K., Jurek, A., Traczykowski, A., Berleć, K., Michalska, M., Piątkowski, J.K. (2013). Przeżywalność bakterii Salmonella Enteritidis w wodach powierzchniowych. Rocznik Ochrona Środowiska, 15, 2738-2749.
- 23. Walczak, M., Lalke-Porczyk, E. (2011). Przeżywalność bakterii w wodach geotermalnych. Technika Poszukiwań Geologicznych, Geotermia, Zrównoważony Rozwój, 1-2, 413-423.
Uwagi
PL
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2018).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-487f3142-1d21-4c2a-8db3-09a0c37ff91c