PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Risk assesment of water vapor condensation in wall made of hemp-lime composite

Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The paper presents issues associated with moisture presence in the wall partitions. As the wall material a lime-hemp composite was selected. Materials containing organic components are sensitive to excessive amount of moisture. One of the most important sources of moisture in the walls is diffusive water vapor, which may condense inside the partition. An important parameter of wall material is water vapor permeability. Inappropriate indor air relative humidity and the temperature of the wall surface can contribute to the growth of mold. In turn, the accumulated condensate inside the barrier, may worsenthe thermal insulation parameters and reduce the durability of the material. For the analysis there were selected two external wall constructions manufactured of the hemp-lime composite in two versions, one insulated from the inside and the second one from the outside with wool hemp. Both variants are finished with plaster or wood cladding. To avoid critical surface humidity, internal surface temperature was calculated and the possibility of interstitial condensation in the analyzed walls was determined. Calculations were made assuming the specified conditions in a monthly cycle for Lublin (Poland) location according to PN-EN 13788 standard.
PL
Praca przedstawia zagadnienia związane z występowaniem wilgoci w przegrodach ściennych. Jako materiał ścienny wybrano kompozyt wapienno-konopny. Materiały zawierające składniki organiczne są wrażliwe na nadmiar wilgotności. Jednym ze źródeł wilgoci w ścianach jest dyfundująca przez nią para wodna, która może ulec skropleniu wewnątrz przegrody. Ważnym parametrem materiału ściennego jest paroprzepuszczalność. Nieodpowiednia wilgotność względna w pomieszczeniu oraz temperatura powierzchni ściany może przyczynić się do rozwoju pleśni. Z kolei nagromadzony kondensat wewnątrz przegrody, może pogorszyć parametry termizolacyjne ściany oraz zmniejszyć trwałość materiału. Analizie poddano ścianę zewnętrzną z kompozytu w dwóch wariantach, ocieploną od wewnątrz i od zewnątrz wełną konopną oraz wykończone tynkiem lub okładziną. Obliczono temperaturę powierzchni konieczną do uniknięcia krytycznej wilgotności powierzchni wewnętrznej ściany oraz określono możliwość wystąpienia kondensacji międzywarstwowej w analizowanych ścianach. Obliczenia wykonano przy założeniu warunków ustalonych w cyklu miesięcznym dla lokalizacji Lublin (Polska) wg normy PN-EN 13788.
Rocznik
Strony
47--56
Opis fizyczny
Bibliogr. 36 poz.
Twórcy
autor
  • Lublin University of Technology, Faculty of Civil Engineering and Architecture, Department of Construction, Nadbystrzycka St. 40, 20-618 Lublin, Poland
Bibliografia
  • [1] Halicka A., Ogrodnik P., Zegardło B.; Using ceramic sanitary ware waste as concrete aggregate. Construction and Building Materials. Vol.48, 2013; p.295-305.
  • [2] Kymalainen H.R., Sjoberg A.M.; Flax and hemp fibres as raw materials for thermal insulations. Building and Environment, Vol.43, No.7, 2008; p.1261-1269.
  • [3] Elfordy S., Lucas F., Tancret F., Scudeller Y., Goudet L.; Mechanical and thermal properties of lime and hemp concrete (hempcrete) manufactured by a projection process. Construction and Building Materials, Vol.22, No.10, 2008; p.2025-2152.
  • [4] Rahim M., Douzane O., Tran Le A.D., Promis G., Langlet T.; Characterization and comparison of hygric properties of rape straw concrete and hemp concrete. Construction and Building Materials, Vol.102, 2016; p.679-687.
  • [5] Labat M., Magniont C., Oudhof N., Aubert J.E.; From the experimental characterization of the hygrothermal properties of straw-clay mixtures to the numerical assessment of their buffering potential. Building and Enviromnent, Vol.97, 2016; p.69-81.
  • [6] Sedlbauer K.; Vorhersage von Schimmelpilzbilung auf und in Bauteilen (Prediction of mold fungus formation on and in components). Fakultat Bauingenieurund Vermessungswesen der Universitat Stuttgart, Dissertation, 2001 (in German).
  • [7] Kuske M., Romain A.C., Nicolas J.; Microbial volatile organic compounds as indicators of fungi. Can an electronic nose detect fungi in indoor environments? Building and Environment, Vol.40, 2005; p.824-831, doi: 10.1016/j.buildenv.2004.08.012.
  • [8] Kuske M., Padilla M., Romain A.C., Nicolas J., Rubio R., Marco S.; Detection of diverse mould species growing on building materials by gas sensor arrays and pattern recognition. Sensors and Actuators B, Vol.119, 2006; p.33-40, doi:10.1016/j.snb.2005.02.059.
  • [9] Pasanen A.L., Juutinen T., Jantunen M.J., Kalliokoski P.; Occurrence and moisture requirements of microbial growth in building materials. International Biodeterioration& Biodegradation, Vol.30, No.4, 1992; p.273-283, doi:10.1016/0964-8305(92)90033-K.
  • [10] Żukiewicz-Sobczak W., Sobczak P., Imbor K., Krasowska E., Zwoliński J., Horoch A., Wojtyła A., Piątek J.; Zagrożenia grzybowe w budynkach i w mieszkaniach – wpływ na organizm człowieka (Fungus danger in buildings and flats – influence on the human body). Medycyna Ogólna i Nauki o Zdrowiu, Vol.18, No.2, 2012, p.141-146 (in Polish).
  • [11] Minke G., Mahlke F.; Building with Straw (Germany: Birkhäuser Architecture), 2005.
  • [12] A. Norhidayah A., Chia-Kuang L., Azhar M.K., Nurulwahida S.; Indoor Air Quality and Sick Building Syndrome in Three Selected Buildings. Procedia Engineering, Vol.53, 2013; p.93-98.
  • [13] Piotrowska M., Żakowska Z., Gliścińska A., Bogusłąwska-Kozłowska J.; Rola mikroflory powietrza zewnętrznego w kształtowaniu bioarozulu grzybowego pomieszczeń zamkniętych (The role of ambient air microflora on formation of fungal bioaerosol in closed rooms). II konferencja naukowa “Rozkład i korozja mikrobiologiczna materiałów technicznych”, 30-31 May 2001, Politechnika Łódzka, Łódź (in Polish).
  • [14] Samson R.A., Flanningan B., Verhoeff A.P., Adan O.C.G., Hoekstra E.S. (ed.); Health Implications of Fungi in Indoor Environments (Air Quality Monographs). Elsevier Science Ltd., 1 edition, Amsterdam, The Netherlands, 1994.
  • [15] Frąc M., Jezierska-Tys S., Tys J.; Populations of selected microbial and fungal species growing on the surface of rape seeds following treatment with desiccants or plant growth regulators. Journal of Toxicology and Environmental Health, Part A, Vol.73, 2010; p.1230-1235.
  • [16] Dylla A.; Fizyka cieplna budowli w praktyce – obliczenia cieplno-wilgotnościowe (Thermal physics of buildings in practice – thermal-moisture calculations). PWN, 2015 (in Polish).
  • [17] Gawin D., Kosny J., Desjarlais A.; Effect of Moisture on Thermal Performance and Energy Efficiency of Buildings with Lightweight Concrete Walls. Proc. 2000 Summer Study on Energy Efficiency in Buildings “Efficiency & Sustainability”, 3.149-3.160, Pacific Grove, California (USA), 2000; p.20-25.
  • [18] Suchorab Z., Barnat-Hunek D., Sobczuk H.; Influence of moisture on heat conductivity coefficient of aerated concrete. Ecological Chemistry and Engineering S-Chemia i Inżynieria Ekologiczna S, Vol.18, No.1, 2011; p.111-120.
  • [19] Antepara I., Fiala L., Pavlik Z., Cerny R.; Moisture Dependent Thermal Properties of Hydrophilic Mineral Wool: Application of the Effective Media Theory. Materials Science-Medziagotyra, Vol.21, No.3, 2015; p.449-454. http://dx.doi.org/10.5755/ j01.ms.21.3.7334.
  • [20] Pavlik Z., Fiala L., Jerman M.,Vejmelková E., Pavlíková M., Keppert M., Černý R.; Theoretical and Experimental Analysis of Moisture-Dependent Thermal Conductivity of Lightweight Ceramic Bricks. International Journal of Thermophysics, Vol.35, No.9, 2014; p.1912-1921.
  • [21] Franus M., Barnat-Hunek D., Wdowin M.; Utilization of sewage sludge in the manufacture of lightweight aggregate. Environmental Monitoring and Assessment, Vol.188, N [22] Suchorab Z., Jedut A., Sobczuk H.; Water content measurement in building barriers and materials using surface TDR probe. Proceedings of ECOpole, Vol.2, No.1, 2008; p.123-127.
  • [23] Rirsch E., Zhang Z.; Rising damp in masonry walls and the importance of mortar properties, Construction and Building Materials, Vol.24, 2010, p.1815-1820, 10.1016/j.conbuildmat.2010.04.024.
  • [24] Suchorab Z., Widomski M., Lagod G., Sobczuk H.; Capillary rise phenomenon in aerated concrete monitoring and simulations. Proceedings of ECOpole, Vol.4, No.2, 2010; p.285-290. [25] Skierucha W., Wilczek A., Szypłowska A., Sławiński C., Lamorski K.; A TDR-Based Soil Moisture Monitoring System with Simultaneous Measurement of Soil Temperature and Electrical Conductivity. Sensors, Vol.12, No.10, 2012; p.13545-13566.
  • [26] Pastuszka T., Krzyszczak J., Slawinski C., Lamorski K.; Effect of Time-Domain Reflectometry probe location on soil moisture measurement during wetting and drying processes. Measurement, Vol.49, 2014; p.182-186.
  • [27] Suchorab Z., Deneka B., Lagod G., Sobczuk H.; Possibility of salinity determination in building materials using the TDR metod. Proceedings of ECOpole, Vol.3, No.1, 2009; p.199-205.
  • [28] Medved I., Cerny R.; Role of Time Relaxation in a One-Dimensional Diffusion-Advection Model of Water and Salt Transport. Advances in Mathematical Physics, Vol.2015 (2015), http://dx.doi.org/10.1155/2015/307312.
  • [29] Velez W., Matta F., Ziehl P.; Electrochemical characterization of early corrosion in prestressed concrete exposed to salt water. Materials and Structures, Vol.49, No.1-2, 2016; p.507-520.
  • [30] Stanwix W., Sparrow A.; The Hempcrete Book – Designing and building with hemp-lime, Green Books, England, 2014.
  • [31] Benfratello S., Capitano C., Peri G., Rizzo G., Scaccianoce G., Sorrentino G.; Thermal and structural properties of a hemp-lime biocomposite. Construction and Building Materials, Vol.48, 2013; p.745-754.
  • [32] Allin S.; Building with Hemp, Seed Press, Ireland, 2012.
  • [33] Bevan R., Woolley T.; Hemp Lime Construction: A Guide to Building with Hemp Lime Composites. Bracknell 2010.
  • [34] Rahim M., Douzane O., Tran Le A.D., Promis G., Laidoudi B., Crigny A., Dupre B., Langlet T.; Characterization of flax lime and hemp lime concretes: Hygric properties and moisture buffer capa city. Energy and Buildings, Vol.88, 2015; p.91-99.
  • [35] Walker R., Pavía S.; Moisture transfer and thermal properties of hemp-lime concretes. Construction and Building Materials, Vol.64, 2014; p.270-276.
  • [36] Shea A., Lawrence M., Walker P.; Hygrothermal performance of an experimental hemp-lime building. Construction and Building Materials, Vol.36, 2012; p.270-275.
Uwagi
Opracowanie ze środków MNiSW w ramach umowy 812/P-DUN/2016 na działalność upowszechniającą naukę.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-470746d6-e2e3-4751-84c8-98906df6327a
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.