Transients impact on power filter circuit sizing

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The practice of operating multiple single-tuned filters in AC electrical arc furnace power supply systems has shown, that frequent energizing unloaded furnace transformer can cause damage of the filters. To examination of supply and filter system configuration impact on switching transient and dynamic overvoltages and overcurrents, an example of 50 MVA arc furnace unit was chosen. The transient analysis has been carried out by simulating within Matlab/Simulink Software. Using ANSI/IEEE Standards paper focuses on the selections of ratings for capacitors and air-core reactors used in multiple single-tuned harmonic filters configurations. Comparison of filter reactor and capacitor bank design based on steady state operation and transformer energizing was shown.
Rocznik
Tom
Strony
111--119
Opis fizyczny
Bibliogr. 10 poz., rys., tab.
Twórcy
autor
  • AGH University of Science and Technology 30-059 Kraków, Al. Mickiewicza 30
autor
  • AGH University of Science and Technology 30-059 Kraków, Al. Mickiewicza 30
Bibliografia
  • [1] Varetsky Y., Gajdzica M.: Analiza procesów zachodzących podczas załączania transformatora pieca łukowego zasilanego z układu z filtrami wyższych harmonicznych, Poznań University of Technology Academic Journals. Electrical Engineering, Zeszyty Naukowe Politechniki Poznańskiej. Elektryka. – 2014 no.79, s. 279-287.
  • [2] Varetsky Y., Damping transients in compensated power supply system. // Proc. of VI Sc. Conf. „Electrical power networks-SIECI 2008” Poland, Szklarska Poręba, September 10–12, 2008. P.397-404.
  • [3] Varetsky Y., Gajdzica M.: Załączanie transformatora pieca łukowego w sieci z układem filtrów wyższych harmonicznych, Przegląd Elektrotechniczny, 2015r, nr.4, s.64-69.
  • [4] Kruczinin M. A., Sawicki A., Piece i urządzenia łukowe, seria Monografie nr 74, Wydawnictwo Politechniki Częstochowskiej, Częstochowa 2010.
  • [5] Wciślik S., Elektrotechnika pieców łukowych prądu przemiennego- zagadnienia wybrane, Kielce 2011.
  • [6] Dudley Richard F., Fellers Clay L., Special Design Considerations for Filter Banks in Arc Furnace Installations, IEEE Transactions on industry applications, vol. 33, no.1, January/February 1997.
  • [7] Bonner J.A., Hurst W.M., Rocamora R.G., Dudley R.F., Sharp M.R., Twiss J.A., Selecting Ratings For Capacitors And Reactors In Applications Involving Multiple Single-Tuned Filters, IEEE Transactions on Power Delivery, Vol.10, No.1., Jan. 1995.
  • [8] ANSI C57.16-1958, “Requirements, terminology and tests codes for dry-type air-core series connected reactors”, New York, IEEE, 1958.
  • [9] IEEE Std 18-1992,‘’IEEE Standard for Shunt Power Capacitors,” New York, IEEE, 1993.
  • [10] Arya S., Bhalja B., Simulation of Steel Melting Furnace in MATLAB and its effect on power Quality problems, National Conference on Recent Trends in Engineering & Technology, 13-14 May 2011.