Analytical Thermo-electric Model of Uncooled Microbolometer

Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Modelling of Microelectromechanical systems (MEMS) is a field of active research. An analytical model of a MEMS device allows significantly reducing the design time because simulating such a model is much faster than Finite Element Method (FEM) simulation. The main idea presented in this paper is the analytical thermo-electric model of uncooled microbolometer. It is shown that the model gives accurate results for a wide range of geometric parameters and material properties.
Słowa kluczowe
Rocznik
Strony
99--105
Opis fizyczny
Bibliogr. 4 poz., rys., wykr.
Twórcy
autor
  • Lodz University of Technology
autor
  • Lodz University of Technology
autor
  • Lodz University of Technology
autor
  • Lviv Polytechnic National University
  • Lodz University of Technology
Bibliografia
  • 1. Chen C., Yi X., Zhang J., Zhao X., “Linear uncooled microbolometer array based on VOx thin films”, Infrared Physics Technology, Vol. 42, Issue 2, Pages 87-90, April 2001.
  • 2. Moreno M., Torres A., Ambrosio R. and Kosareev A. “Cooled Microbolometers with Amorphous Germanium-Silicon (a-GexSiy:H) Thermo-Sensing Films”, Bolometers, Prof. Unil Perera (Ed.), ISBN: 978-953-51-0235-9, InTech, 2012.
  • 3. Saxena R.S., Bhan R.K., Jalwania C.R., Rana P.S., Lomash S.K., “Characterization of area arrays of microbolometer-based un-cooled IR detectors without using ROIC”, Sensors and Actuators A: Physical, Volume 141, Issue 2, pp. 359–366, 15 February 2008.
  • 4. Zając P., Szermer M., Maj C., Zabierowski W., Melnyk M., Matviykiv O., Napieralski A., Lobur M. “Electrothermal FEM Simulation of Uncooled Titanium-based Microbolometer”, IX-th International Conference on Perspective Technologies and Methods in MEMS Design (MEMSTECH), Polyana, UKRAINE, 1 - 2 April 2013.