Adhesion and growth of human osteoblast-like MG 63 cells on titanium and stainless steel samples developed for constructing bone implants

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Titanium and stainless steel are strong, corrosion - resistant and biocompatible metals. Thanks to their remarkable properties, they have been in use for a long time in clinical medicine, mainly for constructing and replacing large joints, in particular the bone-anchoring parts, e.g. cups and stems, and also for fabricating orthopaedic screws and splints. In the Czech Republic, these devices are produced by Beznoska Ltd., and are clinically applied in the Orthopaedic Clinic, Bulovka Faculty Hospital in Prague. This study has investigated the biocompatibility of samples made of pure titanium (according to quality standard ISO 5832-2 ) and corrosion-resistant steel (quality standards ISO 5832-1 and AISI 316L), obtained from Beznoska. In addition to Fe, the steel samples contained C (max. 0.025 wt. %), Si (0.6 wt. %), Mn (1.7 wt. %), P( max. 0.025 wt. %), S(max. 0.003 wt. %), Cr (17.5 wt. %), Ni (13.5 wt. %), Mo (2.8 wt. %), and Cu (max. 0.1 wt. %). The materials were used in the form of square samples (9x9 mm or 30x30 mm, thickness 1 mm ). Both Ti and steel samples were grinded with SiO2. The surface of the steel samples was then treated by polishing with Al2O3 paste (grain size up to 1 μm), while the surface of the Ti samples, i.e. a material not suitable for polishing, was finished by brushing using another type of Al2O3 paste with slightly larger grains. Thus, the surface of the steel samples was finally smoother and glossy, while the Ti surface was rougher and matted. For the in vitro biocompatibility tests, human osteoblast-like MG 63 cells (European Collection of Cell Cultures, Salisbury, UK) were used. The smaller samples (9 x 9 mm) were inserted into polystyrene 2 4-well cell culture plates (TPP, Trasadingen, Switzerland; well diameter 1.5 cm). Each well contained 25000 cells (approx. 14150 cells / cm 2 ) and 1.5 ml of Dulbecco’s Modified Eagle Minimum Essential Medium (DMEM; Sigma, USA, Cat. No. 10270-106) supplemented with 10 % foetal bovine serum (FBS; Gibco, Cat. No. 10270-106) and gentamicin (40 μg/ml, LEK, Slovenia). These samples were used for evaluating the size of the cell spreading area (day 1), and for evaluating cell shape and cell viability (days 1, 4 and 7 after seeding). The size o f the cell spreading area was measured using Atlas Software (Tescan Ltd., Brno, Czech Republic). The viability of the cells was determined by the LIVE/DEAD viability cytotoxicity kit for mammalian cells (Invitrogen, Molecular Probes, USA). The larger samples (30x30 mm) were inserted into GAMA polystyrene dishes (diameter 5 cm; GAMA Group Joint- Stock Company, Ceske Budejovice, Czech Republic) and seeded with 300000 cells/dish (approx. 15300 cells/cm 2) suspended in 9 ml of the above mentioned culture medium. These samples were used for evaluating the cell number on days 1, 4 and 7 after seeding, using a Beckman Vi- CELL XR Cell Analyser automatic cell counter. The results indicated that the number of initially adhering cells on day 1 after seeding was significantly lower on the titanium (5320±390 cells/cm2) and on the stainless steel ( 4110±370 cells/cm 2) than on the control polystyrene culture dishes (7740±350 cells/cm2). However, on day 4 after seeding, the cell population density on both metallic materials studied here became significantly higher than on the control polystyrene dishes (75200±2 890 cells/cm2 on Ti and 90870 ±2350 cells/cm2 on steel vs. 56440±1180 cells/cm2 on polystrene). This suggests faster cell proliferation on both metallic materials than on polystyrene. At the same time, the cell number on the stainless steel samples was significantly higher than on the Ti samples. On day 7, the differences in number of adhered cells on both studied metals and on the control polystyrene substrate was on an average similar (from 328780±680 cells/cm2 to 362200 ±760 cells/cm2). The cell viability on all tested materials was almost 100 % in all culture intervals. The morphology of the cells on the studied materials was similar to the morphology of the adhered cells on the control polystyrene dishes, i.e. the cells were mostly flat and polygonal, and the size of their cell spreading areas w as similar on all tested materials. The cells were distributed homogeneously on the entire material surface, and on day 4 they started to form confluent cell layers (FIG. (1). It can be concluded that the tests of biocompatibility confirmed that the titanium and the stainless steel promoted the adhesion and growth of bone - derived cells, and thus these materials are promising for construction of bone implants and for their good integration with the surrounding bone tissue. Further studies on osteogenic cell differentiation, potential immune activation and the response of the bone cells to growth factors, including bone morphogenetic protein, are in progress.
Słowa kluczowe
Rocznik
Strony
10--11
Opis fizyczny
zdj.
Twórcy
  • Academy of Sciences of the Czech Republic, Institute of Physiology, Videnska 1083, 142 20 Prague 4-Krc, Czech Republic
autor
  • Academy of Sciences of the Czech Republic, Institute of Physiology, Videnska 1083, 142 20 Prague 4-Krc, Czech Republic
autor
  • Academy of Sciences of the Czech Republic, Institute of Physiology, Videnska 1083, 142 20 Prague 4-Krc, Czech Republic
autor
  • Beznoska Ltd., Delnicka 2727, 272 01 Kladno 2 – Krocehlavy, Czech Republic
Bibliografia
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-43d6b09b-9954-4c39-9736-d9e49b79d2d7
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.